Cargando…

Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms

In focused ultrasound (FUS) thermal ablation of diseased tissue, acoustic beam and thermal simulations enable treatment planning and optimization. In this study, a treatment-planning methodology that uses the hybrid angular spectrum (HAS) method and the Pennes’ bioheat equation (PBHE) is experimenta...

Descripción completa

Detalles Bibliográficos
Autores principales: Johnson, Sara L., Christensen, Douglas A., Dillon, Christopher R., Payne, Allison
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6365205/
https://www.ncbi.nlm.nih.gov/pubmed/30320518
http://dx.doi.org/10.1080/02656736.2018.1513168
_version_ 1783393372932669440
author Johnson, Sara L.
Christensen, Douglas A.
Dillon, Christopher R.
Payne, Allison
author_facet Johnson, Sara L.
Christensen, Douglas A.
Dillon, Christopher R.
Payne, Allison
author_sort Johnson, Sara L.
collection PubMed
description In focused ultrasound (FUS) thermal ablation of diseased tissue, acoustic beam and thermal simulations enable treatment planning and optimization. In this study, a treatment-planning methodology that uses the hybrid angular spectrum (HAS) method and the Pennes’ bioheat equation (PBHE) is experimentally validated in homogeneous tissue-mimicking phantoms. Simulated three-dimensional temperature profiles are compared to volumetric MR thermometry imaging (MRTI) of FUS sonications in the phantoms, whose acoustic and thermal properties are independently measured. Additionally, Monte Carlo (MC) uncertainty analysis is performed to quantify the effect of tissue property uncertainties on simulation results. The mean error between simulated and experimental spatiotemporal peak temperature rise was +0.33°C (+6.9%). Despite this error, the experimental temperature rise fell within the expected uncertainty of the simulation, as determined by the MC analysis. The average errors of the simulated transverse and longitudinal full width half maximum (FWHM) of the profiles were –1.9% and 7.5%, respectively. A linear regression and local sensitivity analysis revealed that simulated temperature amplitude is more sensitive to uncertainties in simulation inputs than in the profile width and shape. Acoustic power, acoustic attenuation and thermal conductivity had the greatest impact on peak temperature rise uncertainty; thermal conductivity and volumetric heat capacity had the greatest impact on FWHM uncertainty. This study validates that using the HAS and PBHE method can adequately predict temperature profiles from single sonications in homogeneous media. Further, it informs the need to accurately measure or predict patient-specific properties for improved treatment planning of ablative FUS surgeries.
format Online
Article
Text
id pubmed-6365205
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-63652052019-02-06 Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms Johnson, Sara L. Christensen, Douglas A. Dillon, Christopher R. Payne, Allison Int J Hyperthermia Article In focused ultrasound (FUS) thermal ablation of diseased tissue, acoustic beam and thermal simulations enable treatment planning and optimization. In this study, a treatment-planning methodology that uses the hybrid angular spectrum (HAS) method and the Pennes’ bioheat equation (PBHE) is experimentally validated in homogeneous tissue-mimicking phantoms. Simulated three-dimensional temperature profiles are compared to volumetric MR thermometry imaging (MRTI) of FUS sonications in the phantoms, whose acoustic and thermal properties are independently measured. Additionally, Monte Carlo (MC) uncertainty analysis is performed to quantify the effect of tissue property uncertainties on simulation results. The mean error between simulated and experimental spatiotemporal peak temperature rise was +0.33°C (+6.9%). Despite this error, the experimental temperature rise fell within the expected uncertainty of the simulation, as determined by the MC analysis. The average errors of the simulated transverse and longitudinal full width half maximum (FWHM) of the profiles were –1.9% and 7.5%, respectively. A linear regression and local sensitivity analysis revealed that simulated temperature amplitude is more sensitive to uncertainties in simulation inputs than in the profile width and shape. Acoustic power, acoustic attenuation and thermal conductivity had the greatest impact on peak temperature rise uncertainty; thermal conductivity and volumetric heat capacity had the greatest impact on FWHM uncertainty. This study validates that using the HAS and PBHE method can adequately predict temperature profiles from single sonications in homogeneous media. Further, it informs the need to accurately measure or predict patient-specific properties for improved treatment planning of ablative FUS surgeries. 2018-10-15 2018 /pmc/articles/PMC6365205/ /pubmed/30320518 http://dx.doi.org/10.1080/02656736.2018.1513168 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Published with license by Taylor & Francis Group, LLC
spellingShingle Article
Johnson, Sara L.
Christensen, Douglas A.
Dillon, Christopher R.
Payne, Allison
Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title_full Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title_fullStr Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title_full_unstemmed Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title_short Validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
title_sort validation of hybrid angular spectrum acoustic and thermal modelling in phantoms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6365205/
https://www.ncbi.nlm.nih.gov/pubmed/30320518
http://dx.doi.org/10.1080/02656736.2018.1513168
work_keys_str_mv AT johnsonsaral validationofhybridangularspectrumacousticandthermalmodellinginphantoms
AT christensendouglasa validationofhybridangularspectrumacousticandthermalmodellinginphantoms
AT dillonchristopherr validationofhybridangularspectrumacousticandthermalmodellinginphantoms
AT payneallison validationofhybridangularspectrumacousticandthermalmodellinginphantoms