Cargando…

A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children

BACKGROUND: The early recognition of meningococcal disease in children is vital. During the prodrome however, meningococcal infection presents similarly to many self-limiting viral infections. This mandates a cautious approach with many children receiving unnecessary broad-spectrum parenteral antibi...

Descripción completa

Detalles Bibliográficos
Autores principales: Waterfield, Thomas, Fairley, Derek, Blackwood, Bronagh, McKenna, James, Shields, Michael D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6366060/
https://www.ncbi.nlm.nih.gov/pubmed/30732581
http://dx.doi.org/10.1186/s12887-019-1403-0
_version_ 1783393535253282816
author Waterfield, Thomas
Fairley, Derek
Blackwood, Bronagh
McKenna, James
Shields, Michael D.
author_facet Waterfield, Thomas
Fairley, Derek
Blackwood, Bronagh
McKenna, James
Shields, Michael D.
author_sort Waterfield, Thomas
collection PubMed
description BACKGROUND: The early recognition of meningococcal disease in children is vital. During the prodrome however, meningococcal infection presents similarly to many self-limiting viral infections. This mandates a cautious approach with many children receiving unnecessary broad-spectrum parenteral antibiotics. Advances in nucleic acid amplification techniques mean that it is now possible to test for Neisseria meningitidis DNA using Loop-mediated-isothermal AMPlification (LAMP). This technique is quicker than traditional PCR techniques and can be performed using simple equipment. METHODS: Prior to performing this systematic review, a protocol was developed adhering to PRISMA P standards and underwent full external peer review. This systematic review was registered with PROSPERO (CRD42017078026). The index test assessed was LAMP for Neisseria meningitidis and the reference standard was culture or qPCR of a sterile site detecting Neisseria meningitidis. RESULTS: We identified 95 records in total: 94 records from the electronic databases and 1 additional study from the grey literature. After removal of duplicates, 36 studies were screened, and 31 studies excluded based on the title/abstract. Five full text studies underwent full text review and three studies, including 2243 tests on 1989 patients aged between 7 days and 18 years were included in the final systematic review. In all studies the LAMP assay and qPCR primers were directed against the ctrA region of the Neisseria meningitidis bacteria. The diagnostic accuracy of LAMP testing for invasive meningococcal disease was reported as high (sensitivity 0.84–1.0 and specificity 0.94–1.0) in all studies irrespective of the sample tested (CSF, Blood, Swab). CONCLUSIONS: We included three studies with 2243 tests on 1989 patients using CSF, blood samples or naso/oropharyngeal swabs. The studies were all of a high quality and deemed at low risk of bias. Results show that LAMP testing on blood and CSF was highly accurate when compared to qPCR/culture. LAMP testing for Neisseria meningitidis is fast and highly accurate and therefore has the potential to be used to rapidly rule in/out meningococcal disease in children. Given the life-threatening nature of meningococcal infection further research is required to demonstrate the safety and efficacy of using LAMP testing for Neisseria meningitidis as a rule in/out test. TRIAL REGISTRATION: This systematic review was registered prospectively with PROSPERO on the 29/11/2017 (CRD42017078026). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12887-019-1403-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6366060
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63660602019-02-15 A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children Waterfield, Thomas Fairley, Derek Blackwood, Bronagh McKenna, James Shields, Michael D. BMC Pediatr Research Article BACKGROUND: The early recognition of meningococcal disease in children is vital. During the prodrome however, meningococcal infection presents similarly to many self-limiting viral infections. This mandates a cautious approach with many children receiving unnecessary broad-spectrum parenteral antibiotics. Advances in nucleic acid amplification techniques mean that it is now possible to test for Neisseria meningitidis DNA using Loop-mediated-isothermal AMPlification (LAMP). This technique is quicker than traditional PCR techniques and can be performed using simple equipment. METHODS: Prior to performing this systematic review, a protocol was developed adhering to PRISMA P standards and underwent full external peer review. This systematic review was registered with PROSPERO (CRD42017078026). The index test assessed was LAMP for Neisseria meningitidis and the reference standard was culture or qPCR of a sterile site detecting Neisseria meningitidis. RESULTS: We identified 95 records in total: 94 records from the electronic databases and 1 additional study from the grey literature. After removal of duplicates, 36 studies were screened, and 31 studies excluded based on the title/abstract. Five full text studies underwent full text review and three studies, including 2243 tests on 1989 patients aged between 7 days and 18 years were included in the final systematic review. In all studies the LAMP assay and qPCR primers were directed against the ctrA region of the Neisseria meningitidis bacteria. The diagnostic accuracy of LAMP testing for invasive meningococcal disease was reported as high (sensitivity 0.84–1.0 and specificity 0.94–1.0) in all studies irrespective of the sample tested (CSF, Blood, Swab). CONCLUSIONS: We included three studies with 2243 tests on 1989 patients using CSF, blood samples or naso/oropharyngeal swabs. The studies were all of a high quality and deemed at low risk of bias. Results show that LAMP testing on blood and CSF was highly accurate when compared to qPCR/culture. LAMP testing for Neisseria meningitidis is fast and highly accurate and therefore has the potential to be used to rapidly rule in/out meningococcal disease in children. Given the life-threatening nature of meningococcal infection further research is required to demonstrate the safety and efficacy of using LAMP testing for Neisseria meningitidis as a rule in/out test. TRIAL REGISTRATION: This systematic review was registered prospectively with PROSPERO on the 29/11/2017 (CRD42017078026). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12887-019-1403-0) contains supplementary material, which is available to authorized users. BioMed Central 2019-02-07 /pmc/articles/PMC6366060/ /pubmed/30732581 http://dx.doi.org/10.1186/s12887-019-1403-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Waterfield, Thomas
Fairley, Derek
Blackwood, Bronagh
McKenna, James
Shields, Michael D.
A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title_full A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title_fullStr A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title_full_unstemmed A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title_short A systematic review of the diagnostic accuracy of Loop-mediated-isothermal AMPlification (LAMP) in the diagnosis of invasive meningococcal disease in children
title_sort systematic review of the diagnostic accuracy of loop-mediated-isothermal amplification (lamp) in the diagnosis of invasive meningococcal disease in children
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6366060/
https://www.ncbi.nlm.nih.gov/pubmed/30732581
http://dx.doi.org/10.1186/s12887-019-1403-0
work_keys_str_mv AT waterfieldthomas asystematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT fairleyderek asystematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT blackwoodbronagh asystematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT mckennajames asystematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT shieldsmichaeld asystematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT waterfieldthomas systematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT fairleyderek systematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT blackwoodbronagh systematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT mckennajames systematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren
AT shieldsmichaeld systematicreviewofthediagnosticaccuracyofloopmediatedisothermalamplificationlampinthediagnosisofinvasivemeningococcaldiseaseinchildren