Cargando…
Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry
Background and purpose — Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6366473/ https://www.ncbi.nlm.nih.gov/pubmed/30526183 http://dx.doi.org/10.1080/17453674.2018.1543757 |
_version_ | 1783393632863125504 |
---|---|
author | Horsager, Kristian Madsen, Frank Odgaard, Anders Fink Jepsen, Claus Rømer, Lone Kristensen, Per Wagner Kaptein, Bart L Søballe, Kjeld Stilling, Maiken |
author_facet | Horsager, Kristian Madsen, Frank Odgaard, Anders Fink Jepsen, Claus Rømer, Lone Kristensen, Per Wagner Kaptein, Bart L Søballe, Kjeld Stilling, Maiken |
author_sort | Horsager, Kristian |
collection | PubMed |
description | Background and purpose — Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods — 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results — The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02–0.07) for the cemented group and 0.05 mm/year (CI 0.02–0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI –0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1–5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation — The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang. |
format | Online Article Text |
id | pubmed-6366473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-63664732019-02-15 Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry Horsager, Kristian Madsen, Frank Odgaard, Anders Fink Jepsen, Claus Rømer, Lone Kristensen, Per Wagner Kaptein, Bart L Søballe, Kjeld Stilling, Maiken Acta Orthop Article Background and purpose — Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods — 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results — The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02–0.07) for the cemented group and 0.05 mm/year (CI 0.02–0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI –0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1–5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation — The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang. Taylor & Francis 2019-02 2018-12-10 /pmc/articles/PMC6366473/ /pubmed/30526183 http://dx.doi.org/10.1080/17453674.2018.1543757 Text en © 2018 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Article Horsager, Kristian Madsen, Frank Odgaard, Anders Fink Jepsen, Claus Rømer, Lone Kristensen, Per Wagner Kaptein, Bart L Søballe, Kjeld Stilling, Maiken Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title | Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title_full | Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title_fullStr | Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title_full_unstemmed | Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title_short | Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
title_sort | similar polyethylene wear between cemented and cementless oxford medial uka: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6366473/ https://www.ncbi.nlm.nih.gov/pubmed/30526183 http://dx.doi.org/10.1080/17453674.2018.1543757 |
work_keys_str_mv | AT horsagerkristian similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT madsenfrank similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT odgaardanders similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT finkjepsenclaus similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT rømerlone similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT kristensenperwagner similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT kapteinbartl similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT søballekjeld similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry AT stillingmaiken similarpolyethylenewearbetweencementedandcementlessoxfordmedialukaa5yearfollowuprandomizedcontrolledtrialon79patientsusingradiostereometry |