Cargando…

Visual simulators replicate vision with multifocal lenses

Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IO...

Descripción completa

Detalles Bibliográficos
Autores principales: Vinas, Maria, Benedi-Garcia, Clara, Aissati, Sara, Pascual, Daniel, Akondi, Vyas, Dorronsoro, Carlos, Marcos, Susana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6367467/
https://www.ncbi.nlm.nih.gov/pubmed/30733540
http://dx.doi.org/10.1038/s41598-019-38673-w
_version_ 1783393806243069952
author Vinas, Maria
Benedi-Garcia, Clara
Aissati, Sara
Pascual, Daniel
Akondi, Vyas
Dorronsoro, Carlos
Marcos, Susana
author_facet Vinas, Maria
Benedi-Garcia, Clara
Aissati, Sara
Pascual, Daniel
Akondi, Vyas
Dorronsoro, Carlos
Marcos, Susana
author_sort Vinas, Maria
collection PubMed
description Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves.
format Online
Article
Text
id pubmed-6367467
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-63674672019-02-11 Visual simulators replicate vision with multifocal lenses Vinas, Maria Benedi-Garcia, Clara Aissati, Sara Pascual, Daniel Akondi, Vyas Dorronsoro, Carlos Marcos, Susana Sci Rep Article Adaptive optics (AO) visual simulators based on deformable mirrors, spatial light modulators or optotunable lenses are increasingly used to simulate vision through different multifocal lens designs. However, the correspondence of this simulation with that obtained through real intraocular lenses (IOLs) tested on the same eyes has not been, to our knowledge, demonstrated. We compare through-focus (TF) optical and visual quality produced by real multifocal IOLs (M-IOLs) -bifocal refractive and trifocal diffractive- projected on the subiect’s eye with those same designs simulated with a spatial light modulator (SLM) or an optotunable lens working in temporal multiplexing mode (SimVis technology). Measurements were performed on 7 cyclopleged subjects using a custom-made multichannel 3-active-optical-elements polychromatic AO Visual Simulator in monochromatic light. The same system was used to demonstrate performance of the real IOLs, SLM and SimVis technology simulations on bench using double-pass imaging on an artificial eye. Results show a general good correspondence between the TF performance with the real and simulated M-IOLs, both optically (on bench) and visually (measured visual acuity in patients). We demonstrate that visual simulations in an AO environment capture to a large extent the individual optical and visual performance obtained with real M-IOLs, both in absolute values and in the shape of through-focus curves. Nature Publishing Group UK 2019-02-07 /pmc/articles/PMC6367467/ /pubmed/30733540 http://dx.doi.org/10.1038/s41598-019-38673-w Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Vinas, Maria
Benedi-Garcia, Clara
Aissati, Sara
Pascual, Daniel
Akondi, Vyas
Dorronsoro, Carlos
Marcos, Susana
Visual simulators replicate vision with multifocal lenses
title Visual simulators replicate vision with multifocal lenses
title_full Visual simulators replicate vision with multifocal lenses
title_fullStr Visual simulators replicate vision with multifocal lenses
title_full_unstemmed Visual simulators replicate vision with multifocal lenses
title_short Visual simulators replicate vision with multifocal lenses
title_sort visual simulators replicate vision with multifocal lenses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6367467/
https://www.ncbi.nlm.nih.gov/pubmed/30733540
http://dx.doi.org/10.1038/s41598-019-38673-w
work_keys_str_mv AT vinasmaria visualsimulatorsreplicatevisionwithmultifocallenses
AT benedigarciaclara visualsimulatorsreplicatevisionwithmultifocallenses
AT aissatisara visualsimulatorsreplicatevisionwithmultifocallenses
AT pascualdaniel visualsimulatorsreplicatevisionwithmultifocallenses
AT akondivyas visualsimulatorsreplicatevisionwithmultifocallenses
AT dorronsorocarlos visualsimulatorsreplicatevisionwithmultifocallenses
AT marcossusana visualsimulatorsreplicatevisionwithmultifocallenses