Cargando…

Simulation of pressure support for spontaneous breathing trials in neonates

BACKGROUND: Endotracheal tubes used for neonates are not as resistant to breathing as originally anticipated; therefore, spontaneous breathing trials (SBTs) with continuous positive airway pressure (CPAP), without pressure support (PS), are recommended. However, PS extubation criteria have predeterm...

Descripción completa

Detalles Bibliográficos
Autores principales: Sasaki, Makoto, Yamaguchi, Yoshikazu, Miyashita, Tetsuya, Matsuda, Yuko, Ohtsuka, Masahide, Yamaguchi, Osamu, Goto, Takahisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368635/
https://www.ncbi.nlm.nih.gov/pubmed/30737561
http://dx.doi.org/10.1186/s40635-019-0223-8
_version_ 1783394025389162496
author Sasaki, Makoto
Yamaguchi, Yoshikazu
Miyashita, Tetsuya
Matsuda, Yuko
Ohtsuka, Masahide
Yamaguchi, Osamu
Goto, Takahisa
author_facet Sasaki, Makoto
Yamaguchi, Yoshikazu
Miyashita, Tetsuya
Matsuda, Yuko
Ohtsuka, Masahide
Yamaguchi, Osamu
Goto, Takahisa
author_sort Sasaki, Makoto
collection PubMed
description BACKGROUND: Endotracheal tubes used for neonates are not as resistant to breathing as originally anticipated; therefore, spontaneous breathing trials (SBTs) with continuous positive airway pressure (CPAP), without pressure support (PS), are recommended. However, PS extubation criteria have predetermined pressure values for each endotracheal tube diameter (PS 10 cmH(2)O with 3.0- and 3.5-mm tubes or PS 8 cmH(2)O with 4.0-mm tubes). This study aimed to assess the validity of these SBT criteria for neonates, using an artificial lung simulator, ASL 5000™ lung simulator, and a SERVO-i Universal™ ventilator (minute volume, 240–360 mL/kg/min; tidal volume, 30 mL; respiratory rate, 24–36/min; lung compliance, 0.5 mL/cmH(2)O/kg; resistance, 40 cmH(2)O/L/s) in an intensive care unit. We simulated a spontaneous breathing test in a 3-kg neonate after cardiac surgery with 3.0–3.5-mm endotracheal tubes. We measured the work of breathing (WOB), trigger work, and parameters of pressure support ventilation (PSV), T-piece breathing, or ASL 5000™ alone. RESULTS: WOB displayed respiratory rate dependency under intubation. PS compensating tube resistance fluctuated with respiratory rate. At a respiratory rate of 24/min, the endotracheal tube did not greatly influence WOB under PSV and the regression line of WOB converged with the WOB of ASL 5000™ alone under PS 1 cmH(2)O; however, at 36/min, endotracheal tube was resistant to breathing under PSV because trigger work increased exponentially with PS ≤ 9 cmH(2)O. The regression line of WOB under PSV converged with the WOB of T-piece breathing under PS 1 cmH(2)O. Furthermore, PS compensating endotracheal tube resistance was 6 cmH(2)O. The WOB of ASL 5000™ alone approached that of respiratory distress syndrome (RDS); however, the pressure of patient effort was normal physiological range at PS 10 cmH(2)O. PS equalizing WOB under PSV with that after extubation depended on the respiratory rate and upper airway resistance. If WOB after extubation equaled that of T-piece breathing, the PS was 0 cmH(2)O regardless of the respiratory rates. If WOB after extubation approximated  to that of ASL 5000™ alone, the PS depended on the respiratory rate. CONCLUSION: SBT strategies should be selected per neonatal respiratory rates and upper airway resistance.
format Online
Article
Text
id pubmed-6368635
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-63686352019-02-28 Simulation of pressure support for spontaneous breathing trials in neonates Sasaki, Makoto Yamaguchi, Yoshikazu Miyashita, Tetsuya Matsuda, Yuko Ohtsuka, Masahide Yamaguchi, Osamu Goto, Takahisa Intensive Care Med Exp Research BACKGROUND: Endotracheal tubes used for neonates are not as resistant to breathing as originally anticipated; therefore, spontaneous breathing trials (SBTs) with continuous positive airway pressure (CPAP), without pressure support (PS), are recommended. However, PS extubation criteria have predetermined pressure values for each endotracheal tube diameter (PS 10 cmH(2)O with 3.0- and 3.5-mm tubes or PS 8 cmH(2)O with 4.0-mm tubes). This study aimed to assess the validity of these SBT criteria for neonates, using an artificial lung simulator, ASL 5000™ lung simulator, and a SERVO-i Universal™ ventilator (minute volume, 240–360 mL/kg/min; tidal volume, 30 mL; respiratory rate, 24–36/min; lung compliance, 0.5 mL/cmH(2)O/kg; resistance, 40 cmH(2)O/L/s) in an intensive care unit. We simulated a spontaneous breathing test in a 3-kg neonate after cardiac surgery with 3.0–3.5-mm endotracheal tubes. We measured the work of breathing (WOB), trigger work, and parameters of pressure support ventilation (PSV), T-piece breathing, or ASL 5000™ alone. RESULTS: WOB displayed respiratory rate dependency under intubation. PS compensating tube resistance fluctuated with respiratory rate. At a respiratory rate of 24/min, the endotracheal tube did not greatly influence WOB under PSV and the regression line of WOB converged with the WOB of ASL 5000™ alone under PS 1 cmH(2)O; however, at 36/min, endotracheal tube was resistant to breathing under PSV because trigger work increased exponentially with PS ≤ 9 cmH(2)O. The regression line of WOB under PSV converged with the WOB of T-piece breathing under PS 1 cmH(2)O. Furthermore, PS compensating endotracheal tube resistance was 6 cmH(2)O. The WOB of ASL 5000™ alone approached that of respiratory distress syndrome (RDS); however, the pressure of patient effort was normal physiological range at PS 10 cmH(2)O. PS equalizing WOB under PSV with that after extubation depended on the respiratory rate and upper airway resistance. If WOB after extubation equaled that of T-piece breathing, the PS was 0 cmH(2)O regardless of the respiratory rates. If WOB after extubation approximated  to that of ASL 5000™ alone, the PS depended on the respiratory rate. CONCLUSION: SBT strategies should be selected per neonatal respiratory rates and upper airway resistance. Springer International Publishing 2019-02-08 /pmc/articles/PMC6368635/ /pubmed/30737561 http://dx.doi.org/10.1186/s40635-019-0223-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Sasaki, Makoto
Yamaguchi, Yoshikazu
Miyashita, Tetsuya
Matsuda, Yuko
Ohtsuka, Masahide
Yamaguchi, Osamu
Goto, Takahisa
Simulation of pressure support for spontaneous breathing trials in neonates
title Simulation of pressure support for spontaneous breathing trials in neonates
title_full Simulation of pressure support for spontaneous breathing trials in neonates
title_fullStr Simulation of pressure support for spontaneous breathing trials in neonates
title_full_unstemmed Simulation of pressure support for spontaneous breathing trials in neonates
title_short Simulation of pressure support for spontaneous breathing trials in neonates
title_sort simulation of pressure support for spontaneous breathing trials in neonates
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368635/
https://www.ncbi.nlm.nih.gov/pubmed/30737561
http://dx.doi.org/10.1186/s40635-019-0223-8
work_keys_str_mv AT sasakimakoto simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT yamaguchiyoshikazu simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT miyashitatetsuya simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT matsudayuko simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT ohtsukamasahide simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT yamaguchiosamu simulationofpressuresupportforspontaneousbreathingtrialsinneonates
AT gototakahisa simulationofpressuresupportforspontaneousbreathingtrialsinneonates