Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cycli...

Descripción completa

Detalles Bibliográficos
Autores principales: Uslu, Gülşah, Özyürek, Taha, Gündoğar, Mustafa, Yılmaz, Koray
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368948/
https://www.ncbi.nlm.nih.gov/pubmed/30774795
http://dx.doi.org/10.15171/joddd.2018.044
_version_ 1783394087925186560
author Uslu, Gülşah
Özyürek, Taha
Gündoğar, Mustafa
Yılmaz, Koray
author_facet Uslu, Gülşah
Özyürek, Taha
Gündoğar, Mustafa
Yılmaz, Koray
author_sort Uslu, Gülşah
collection PubMed
description Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.
format Online
Article
Text
id pubmed-6368948
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-63689482019-02-15 Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature Uslu, Gülşah Özyürek, Taha Gündoğar, Mustafa Yılmaz, Koray J Dent Res Dent Clin Dent Prospects Original Article Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files. Tabriz University of Medical Sciences 2018 2018-12-19 /pmc/articles/PMC6368948/ /pubmed/30774795 http://dx.doi.org/10.15171/joddd.2018.044 Text en © 2018 Uslu et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Uslu, Gülşah
Özyürek, Taha
Gündoğar, Mustafa
Yılmaz, Koray
Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title_full Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title_fullStr Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title_full_unstemmed Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title_short Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
title_sort cyclic fatigue resistance of 2shape, twisted file and endosequence xpress nickel-titanium rotary files at intracanal temperature
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368948/
https://www.ncbi.nlm.nih.gov/pubmed/30774795
http://dx.doi.org/10.15171/joddd.2018.044
work_keys_str_mv AT uslugulsah cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature
AT ozyurektaha cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature
AT gundogarmustafa cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature
AT yılmazkoray cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature