Cargando…
Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature
Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cycli...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368948/ https://www.ncbi.nlm.nih.gov/pubmed/30774795 http://dx.doi.org/10.15171/joddd.2018.044 |
_version_ | 1783394087925186560 |
---|---|
author | Uslu, Gülşah Özyürek, Taha Gündoğar, Mustafa Yılmaz, Koray |
author_facet | Uslu, Gülşah Özyürek, Taha Gündoğar, Mustafa Yılmaz, Koray |
author_sort | Uslu, Gülşah |
collection | PubMed |
description | Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files. |
format | Online Article Text |
id | pubmed-6368948 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-63689482019-02-15 Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature Uslu, Gülşah Özyürek, Taha Gündoğar, Mustafa Yılmaz, Koray J Dent Res Dent Clin Dent Prospects Original Article Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>0.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files. Tabriz University of Medical Sciences 2018 2018-12-19 /pmc/articles/PMC6368948/ /pubmed/30774795 http://dx.doi.org/10.15171/joddd.2018.044 Text en © 2018 Uslu et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Uslu, Gülşah Özyürek, Taha Gündoğar, Mustafa Yılmaz, Koray Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title | Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title_full | Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title_fullStr | Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title_full_unstemmed | Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title_short | Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature |
title_sort | cyclic fatigue resistance of 2shape, twisted file and endosequence xpress nickel-titanium rotary files at intracanal temperature |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6368948/ https://www.ncbi.nlm.nih.gov/pubmed/30774795 http://dx.doi.org/10.15171/joddd.2018.044 |
work_keys_str_mv | AT uslugulsah cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature AT ozyurektaha cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature AT gundogarmustafa cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature AT yılmazkoray cyclicfatigueresistanceof2shapetwistedfileandendosequencexpressnickeltitaniumrotaryfilesatintracanaltemperature |