Cargando…

Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants

BACKGROUND: This study assessed the relationship between insertion torque and bone quality evaluated during surgery and in preoperative computed tomographic (CT) images analyzed either visually or by rescaled mean gray values (MGVs). The study also tested the correlation between the clinical and rad...

Descripción completa

Detalles Bibliográficos
Autores principales: Triches, Diego Fernandes, Alonso, Fernando Rizzo, Mezzomo, Luis André, Schneider, Danilo Renato, Villarinho, Eduardo Aydos, Rockenbach, Maria Ivete, Teixeira, Eduardo Rolim, Shinkai, Rosemary Sadami
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6369231/
https://www.ncbi.nlm.nih.gov/pubmed/30740630
http://dx.doi.org/10.1186/s40729-019-0158-6
_version_ 1783394143842598912
author Triches, Diego Fernandes
Alonso, Fernando Rizzo
Mezzomo, Luis André
Schneider, Danilo Renato
Villarinho, Eduardo Aydos
Rockenbach, Maria Ivete
Teixeira, Eduardo Rolim
Shinkai, Rosemary Sadami
author_facet Triches, Diego Fernandes
Alonso, Fernando Rizzo
Mezzomo, Luis André
Schneider, Danilo Renato
Villarinho, Eduardo Aydos
Rockenbach, Maria Ivete
Teixeira, Eduardo Rolim
Shinkai, Rosemary Sadami
author_sort Triches, Diego Fernandes
collection PubMed
description BACKGROUND: This study assessed the relationship between insertion torque and bone quality evaluated during surgery and in preoperative computed tomographic (CT) images analyzed either visually or by rescaled mean gray values (MGVs). The study also tested the correlation between the clinical and radiographic measures of bone quality. METHODS: The consecutive sample was composed of 45 short implants (4.1 × 6 mm) placed in the posterior region of 20 patients. Intra-surgical tactile bone quality, based on the classification of bone types by Lekholm and Zarb, and insertion torque were recorded during the implant placement. Visual bone quality and normalized MGV were assessed in standardized axial, coronal, and sagittal sections of preoperative CT images. Data were analyzed by ANOVA and Spearman correlation (alpha = 0.05). RESULTS: Insertion torque was associated with all assessment methods of bone quality (tactile, CT visual, MGV). A moderate correlation was found among all methods of bone quality, except for CT visual assessment and tactile evaluation. MGVs varied as a function of arch, dental region, insertion torque, and bone types. CONCLUSIONS: The results suggest that bone quality measures affect primary stability as recorded by insertion torque, and the assessment methods are consistently related.
format Online
Article
Text
id pubmed-6369231
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-63692312019-03-01 Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants Triches, Diego Fernandes Alonso, Fernando Rizzo Mezzomo, Luis André Schneider, Danilo Renato Villarinho, Eduardo Aydos Rockenbach, Maria Ivete Teixeira, Eduardo Rolim Shinkai, Rosemary Sadami Int J Implant Dent Research BACKGROUND: This study assessed the relationship between insertion torque and bone quality evaluated during surgery and in preoperative computed tomographic (CT) images analyzed either visually or by rescaled mean gray values (MGVs). The study also tested the correlation between the clinical and radiographic measures of bone quality. METHODS: The consecutive sample was composed of 45 short implants (4.1 × 6 mm) placed in the posterior region of 20 patients. Intra-surgical tactile bone quality, based on the classification of bone types by Lekholm and Zarb, and insertion torque were recorded during the implant placement. Visual bone quality and normalized MGV were assessed in standardized axial, coronal, and sagittal sections of preoperative CT images. Data were analyzed by ANOVA and Spearman correlation (alpha = 0.05). RESULTS: Insertion torque was associated with all assessment methods of bone quality (tactile, CT visual, MGV). A moderate correlation was found among all methods of bone quality, except for CT visual assessment and tactile evaluation. MGVs varied as a function of arch, dental region, insertion torque, and bone types. CONCLUSIONS: The results suggest that bone quality measures affect primary stability as recorded by insertion torque, and the assessment methods are consistently related. Springer Berlin Heidelberg 2019-02-11 /pmc/articles/PMC6369231/ /pubmed/30740630 http://dx.doi.org/10.1186/s40729-019-0158-6 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Triches, Diego Fernandes
Alonso, Fernando Rizzo
Mezzomo, Luis André
Schneider, Danilo Renato
Villarinho, Eduardo Aydos
Rockenbach, Maria Ivete
Teixeira, Eduardo Rolim
Shinkai, Rosemary Sadami
Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title_full Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title_fullStr Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title_full_unstemmed Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title_short Relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
title_sort relation between insertion torque and tactile, visual, and rescaled gray value measures of bone quality: a cross-sectional clinical study with short implants
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6369231/
https://www.ncbi.nlm.nih.gov/pubmed/30740630
http://dx.doi.org/10.1186/s40729-019-0158-6
work_keys_str_mv AT trichesdiegofernandes relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT alonsofernandorizzo relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT mezzomoluisandre relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT schneiderdanilorenato relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT villarinhoeduardoaydos relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT rockenbachmariaivete relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT teixeiraeduardorolim relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants
AT shinkairosemarysadami relationbetweeninsertiontorqueandtactilevisualandrescaledgrayvaluemeasuresofbonequalityacrosssectionalclinicalstudywithshortimplants