Cargando…

“Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract

This report describes two maneuvers in different steps of phaco surgery in a case with hard cataract, which provide debulking of the central dense nucleus and prevents posterior capsule rupture (PCR). In the current case, clear corneal incisions were created, and anterior chamber was filled with oph...

Descripción completa

Detalles Bibliográficos
Autores principales: Toprak, Ibrahim, Yaylali, Volkan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6369501/
https://www.ncbi.nlm.nih.gov/pubmed/30833969
http://dx.doi.org/10.1155/2019/9043417
_version_ 1783394205426515968
author Toprak, Ibrahim
Yaylali, Volkan
author_facet Toprak, Ibrahim
Yaylali, Volkan
author_sort Toprak, Ibrahim
collection PubMed
description This report describes two maneuvers in different steps of phaco surgery in a case with hard cataract, which provide debulking of the central dense nucleus and prevents posterior capsule rupture (PCR). In the current case, clear corneal incisions were created, and anterior chamber was filled with ophthalmic viscosurgical device (OVD). Anterior capsule was punctured, and capsulorhexis was completed. Nucleus was cracked into two halves following vertical groove formation. Core nucleus was hollowed sideward bilaterally in the capsular bag. Nuclear halves were removed from capsular bag, and each one was pushed to one side on the iris plane. Capsular bag was inflated with OVD, and intraocular lens (IOL) was implanted. Nuclear halves were removed in confidence. The presented maneuvers initially reduce dense nucleus load in the safe zone and allow surgeon to use IOL as a barrier to protect floppy posterior capsule from early steps of the surgery.
format Online
Article
Text
id pubmed-6369501
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-63695012019-03-04 “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract Toprak, Ibrahim Yaylali, Volkan Case Rep Med Case Report This report describes two maneuvers in different steps of phaco surgery in a case with hard cataract, which provide debulking of the central dense nucleus and prevents posterior capsule rupture (PCR). In the current case, clear corneal incisions were created, and anterior chamber was filled with ophthalmic viscosurgical device (OVD). Anterior capsule was punctured, and capsulorhexis was completed. Nucleus was cracked into two halves following vertical groove formation. Core nucleus was hollowed sideward bilaterally in the capsular bag. Nuclear halves were removed from capsular bag, and each one was pushed to one side on the iris plane. Capsular bag was inflated with OVD, and intraocular lens (IOL) was implanted. Nuclear halves were removed in confidence. The presented maneuvers initially reduce dense nucleus load in the safe zone and allow surgeon to use IOL as a barrier to protect floppy posterior capsule from early steps of the surgery. Hindawi 2019-01-27 /pmc/articles/PMC6369501/ /pubmed/30833969 http://dx.doi.org/10.1155/2019/9043417 Text en Copyright © 2019 Ibrahim Toprak and Volkan Yaylali. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Toprak, Ibrahim
Yaylali, Volkan
“Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title_full “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title_fullStr “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title_full_unstemmed “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title_short “Crack, Reduce, and Implant”: A Safe Phaco Technique in a Case with Hard Brown Cataract
title_sort “crack, reduce, and implant”: a safe phaco technique in a case with hard brown cataract
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6369501/
https://www.ncbi.nlm.nih.gov/pubmed/30833969
http://dx.doi.org/10.1155/2019/9043417
work_keys_str_mv AT toprakibrahim crackreduceandimplantasafephacotechniqueinacasewithhardbrowncataract
AT yaylalivolkan crackreduceandimplantasafephacotechniqueinacasewithhardbrowncataract