Cargando…

Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph

BACKGROUND/OBJECTIVE: The application of Micro-Electro-Mechanical Sensors (MEMS) as measurements of energy expenditure (EE) has certain disadvantages. For example, the inertial sensors cannot easily distinguish changes in ground slope during walking/running conditions, so the accuracy of EE calculat...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Chun-Hao, Lin, Kuo-Chuan, Ho, Chin-Shan, Huang, Chi-Chang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Chinese Scholars on Exercise Physiology and Fitness 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370579/
https://www.ncbi.nlm.nih.gov/pubmed/30792740
http://dx.doi.org/10.1016/j.jesf.2019.01.003
_version_ 1783394369877835776
author Chang, Chun-Hao
Lin, Kuo-Chuan
Ho, Chin-Shan
Huang, Chi-Chang
author_facet Chang, Chun-Hao
Lin, Kuo-Chuan
Ho, Chin-Shan
Huang, Chi-Chang
author_sort Chang, Chun-Hao
collection PubMed
description BACKGROUND/OBJECTIVE: The application of Micro-Electro-Mechanical Sensors (MEMS) as measurements of energy expenditure (EE) has certain disadvantages. For example, the inertial sensors cannot easily distinguish changes in ground slope during walking/running conditions, so the accuracy of EE calculation is biased. To resolve this issue, heart rate (HR) and heart rate reserve (HRR) were used as compensatory factors respectively to correct the classical empirical formula of the accelerometer analyzer for EE in this study. METHODS: To explore the improvement of the accuracy of EE during uphill exercise and compare the correction levels between HR and HRR, oxygen uptake was used as a criterion measure (CM). Thirty healthy adult males wore an ActiGraph GT3X with the Polar HR monitor and Vmax indirect calorimeter during twelve treadmill activities (3 gradients and 4 speeds). RESULTS: When the slopes were increased by 0%, 3%, and 6%, the measurement accuracy of the accelerometers, calculated by intraclass correlation coefficient (ICC), decreased by 0.877, 0.755, and 0.504, respectively (p < 0.05). The HR and HRR parameters of linear regression were used to correct the classical formula. The results showed that HR had higher coefficients of determination (R2) (0.801, 0.700, and 0.642 respectively) and ICCs (0.887, 0.825, and 0.785 respectively) than did the accelerometer outputs. HRR showed the highest coefficients of determination (R2) (0.821, 0.728, and 0.656 respectively) and ICCs (0.901, 0.844, and 0.795 respectively). CONCLUSIONS: Through adding HRR parameters, the accuracy of the classical prediction formula EE was significantly improved during walking/running on sloping ground.
format Online
Article
Text
id pubmed-6370579
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Society of Chinese Scholars on Exercise Physiology and Fitness
record_format MEDLINE/PubMed
spelling pubmed-63705792019-02-21 Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph Chang, Chun-Hao Lin, Kuo-Chuan Ho, Chin-Shan Huang, Chi-Chang J Exerc Sci Fit Original Article BACKGROUND/OBJECTIVE: The application of Micro-Electro-Mechanical Sensors (MEMS) as measurements of energy expenditure (EE) has certain disadvantages. For example, the inertial sensors cannot easily distinguish changes in ground slope during walking/running conditions, so the accuracy of EE calculation is biased. To resolve this issue, heart rate (HR) and heart rate reserve (HRR) were used as compensatory factors respectively to correct the classical empirical formula of the accelerometer analyzer for EE in this study. METHODS: To explore the improvement of the accuracy of EE during uphill exercise and compare the correction levels between HR and HRR, oxygen uptake was used as a criterion measure (CM). Thirty healthy adult males wore an ActiGraph GT3X with the Polar HR monitor and Vmax indirect calorimeter during twelve treadmill activities (3 gradients and 4 speeds). RESULTS: When the slopes were increased by 0%, 3%, and 6%, the measurement accuracy of the accelerometers, calculated by intraclass correlation coefficient (ICC), decreased by 0.877, 0.755, and 0.504, respectively (p < 0.05). The HR and HRR parameters of linear regression were used to correct the classical formula. The results showed that HR had higher coefficients of determination (R2) (0.801, 0.700, and 0.642 respectively) and ICCs (0.887, 0.825, and 0.785 respectively) than did the accelerometer outputs. HRR showed the highest coefficients of determination (R2) (0.821, 0.728, and 0.656 respectively) and ICCs (0.901, 0.844, and 0.795 respectively). CONCLUSIONS: Through adding HRR parameters, the accuracy of the classical prediction formula EE was significantly improved during walking/running on sloping ground. The Society of Chinese Scholars on Exercise Physiology and Fitness 2019-01-20 2019-01-23 /pmc/articles/PMC6370579/ /pubmed/30792740 http://dx.doi.org/10.1016/j.jesf.2019.01.003 Text en © 2019 The Society of Chinese Scholars on Exercise Physiology and Fitness. Published by Elsevier (Singapore) Pte Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Chang, Chun-Hao
Lin, Kuo-Chuan
Ho, Chin-Shan
Huang, Chi-Chang
Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title_full Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title_fullStr Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title_full_unstemmed Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title_short Accuracy of the energy expenditure during uphill exercise measured by the Waist-worn ActiGraph
title_sort accuracy of the energy expenditure during uphill exercise measured by the waist-worn actigraph
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370579/
https://www.ncbi.nlm.nih.gov/pubmed/30792740
http://dx.doi.org/10.1016/j.jesf.2019.01.003
work_keys_str_mv AT changchunhao accuracyoftheenergyexpenditureduringuphillexercisemeasuredbythewaistwornactigraph
AT linkuochuan accuracyoftheenergyexpenditureduringuphillexercisemeasuredbythewaistwornactigraph
AT hochinshan accuracyoftheenergyexpenditureduringuphillexercisemeasuredbythewaistwornactigraph
AT huangchichang accuracyoftheenergyexpenditureduringuphillexercisemeasuredbythewaistwornactigraph