Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method
TomoDirect has been reported to have some advantages over TomoHelical in delivering total body irradiation (TBI). This study aimed to investigate the relationships between the number of ports and the dose evaluation indices in low‐dose TBI in TomoDirect mode using 2–12 ports and to compare these dat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370990/ https://www.ncbi.nlm.nih.gov/pubmed/30721567 http://dx.doi.org/10.1002/acm2.12540 |
_version_ | 1783394470738264064 |
---|---|
author | Kasai, Yuki Fukuyama, Yukihide Terashima, Hiromi Nakamura, Katsumasa Sasaki, Tomonari |
author_facet | Kasai, Yuki Fukuyama, Yukihide Terashima, Hiromi Nakamura, Katsumasa Sasaki, Tomonari |
author_sort | Kasai, Yuki |
collection | PubMed |
description | TomoDirect has been reported to have some advantages over TomoHelical in delivering total body irradiation (TBI). This study aimed to investigate the relationships between the number of ports and the dose evaluation indices in low‐dose TBI in TomoDirect mode using 2–12 ports and to compare these data with those for the TomoHelical mode in a simulation study. Thirteen patients underwent low‐dose TBI in TomoHelical mode from June 2015 to June 2016. We used the same computed tomography data sets for these patients to create new treatment plans for upper‐body parts using TomoDirect mode with 2–12 beam angles as well as TomoHelical mode. The prescription was 4 Gy in two equal fractions. For the TomoDirect data, we generated plans with 2–12 ports with approximately equally spaced angles; the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.500, respectively. For the TomoHelical plans, the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.397, respectively. D2, D98, D50, and the homogeneity index (HI) were evaluated to compare TomoDirect plans having 2–12 ports with the TomoHelical plan. Using TomoDirect plans, D2 with four ports or fewer, D98 with 10 ports or fewer, D50 with four ports or fewer and HI with five ports or fewer showed statistically significantly worse results than the TomoHelical plan. With the TomoDirect plans, D2 with seven ports or more, D50 with eight ports or more, and HI with eight ports or more showed statistically significant improvement compared with the TomoHelical plan. All of the dose evaluation indices of the TomoDirect plans showed a tendency to improve as the number of ports increased. TomoDirect plans showed statistically significant improvement of D2, D50, and HI compared with the TomoHelical plan. Therefore, we conclude that TomoDirect can provide better dose distribution in low‐dose TBI with TomoTherapy. |
format | Online Article Text |
id | pubmed-6370990 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63709902019-02-21 Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method Kasai, Yuki Fukuyama, Yukihide Terashima, Hiromi Nakamura, Katsumasa Sasaki, Tomonari J Appl Clin Med Phys Radiation Oncology Physics TomoDirect has been reported to have some advantages over TomoHelical in delivering total body irradiation (TBI). This study aimed to investigate the relationships between the number of ports and the dose evaluation indices in low‐dose TBI in TomoDirect mode using 2–12 ports and to compare these data with those for the TomoHelical mode in a simulation study. Thirteen patients underwent low‐dose TBI in TomoHelical mode from June 2015 to June 2016. We used the same computed tomography data sets for these patients to create new treatment plans for upper‐body parts using TomoDirect mode with 2–12 beam angles as well as TomoHelical mode. The prescription was 4 Gy in two equal fractions. For the TomoDirect data, we generated plans with 2–12 ports with approximately equally spaced angles; the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.500, respectively. For the TomoHelical plans, the modulation factor, field width, and pitch were 2.0, 5.0 cm, and 0.397, respectively. D2, D98, D50, and the homogeneity index (HI) were evaluated to compare TomoDirect plans having 2–12 ports with the TomoHelical plan. Using TomoDirect plans, D2 with four ports or fewer, D98 with 10 ports or fewer, D50 with four ports or fewer and HI with five ports or fewer showed statistically significantly worse results than the TomoHelical plan. With the TomoDirect plans, D2 with seven ports or more, D50 with eight ports or more, and HI with eight ports or more showed statistically significant improvement compared with the TomoHelical plan. All of the dose evaluation indices of the TomoDirect plans showed a tendency to improve as the number of ports increased. TomoDirect plans showed statistically significant improvement of D2, D50, and HI compared with the TomoHelical plan. Therefore, we conclude that TomoDirect can provide better dose distribution in low‐dose TBI with TomoTherapy. John Wiley and Sons Inc. 2019-02-05 /pmc/articles/PMC6370990/ /pubmed/30721567 http://dx.doi.org/10.1002/acm2.12540 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Kasai, Yuki Fukuyama, Yukihide Terashima, Hiromi Nakamura, Katsumasa Sasaki, Tomonari Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title | Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title_full | Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title_fullStr | Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title_full_unstemmed | Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title_short | Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method |
title_sort | dose evaluation indices for total body irradiation using tomodirect with different numbers of ports: a comparison with the tomohelical method |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6370990/ https://www.ncbi.nlm.nih.gov/pubmed/30721567 http://dx.doi.org/10.1002/acm2.12540 |
work_keys_str_mv | AT kasaiyuki doseevaluationindicesfortotalbodyirradiationusingtomodirectwithdifferentnumbersofportsacomparisonwiththetomohelicalmethod AT fukuyamayukihide doseevaluationindicesfortotalbodyirradiationusingtomodirectwithdifferentnumbersofportsacomparisonwiththetomohelicalmethod AT terashimahiromi doseevaluationindicesfortotalbodyirradiationusingtomodirectwithdifferentnumbersofportsacomparisonwiththetomohelicalmethod AT nakamurakatsumasa doseevaluationindicesfortotalbodyirradiationusingtomodirectwithdifferentnumbersofportsacomparisonwiththetomohelicalmethod AT sasakitomonari doseevaluationindicesfortotalbodyirradiationusingtomodirectwithdifferentnumbersofportsacomparisonwiththetomohelicalmethod |