Cargando…
Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study
The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated. To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372013/ https://www.ncbi.nlm.nih.gov/pubmed/30142870 http://dx.doi.org/10.1097/MD.0000000000012117 |
_version_ | 1783394673037934592 |
---|---|
author | Feng, Chunguang Zhang, Peiying Han, Bing Li, Xianchi Liu, Yi Niu, Dongdong Shi, Yibing |
author_facet | Feng, Chunguang Zhang, Peiying Han, Bing Li, Xianchi Liu, Yi Niu, Dongdong Shi, Yibing |
author_sort | Feng, Chunguang |
collection | PubMed |
description | The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated. To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of the stent treatment failure. A total of 70 patients with drug-eluting ISR undergoing OCT were enrolled (intimal hyperplasia ≥50% of stent area) and implanted with drug-eluting stents. According to stent implantation time, the patients were divided into 2 groups: early in-stent restenosis group (E-ISR group) (group A, n = 35, stent age ≤12 months) and late in-stent restenosis group (L-ISR group) (group B, n = 35, stent age ≥24 months). A qualitative analysis of the restenosis tissue included the nature of restenosis tissue (homogeneous and heterogeneous), neoatherosclerosis, thin-cap fibroatheroma (TCFA), and microvessels. The ratio of ≥75% cross-sectional area stenosis between the L-ISR and E-ISR groups was (60.00% vs 34.28%, P < .05). The heterogeneous intima, neoatherosclerosis, TCFA, and microvessels were more prevalent in the L-ISR group as compared to the E-ISR group (71.43% vs 45.71%, P < .05; 48.57% vs 22.86%, P < .05; 25.71% vs 5.71%, P < .05; 22.86% vs 2.86%, P < .05, respectively). The morphological characteristics of L-ISR were significantly different from those in the E-ISR; the former was closer to the atherosclerotic plaque, which provided a new approach for the treatment of drug-eluting ISR. |
format | Online Article Text |
id | pubmed-6372013 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-63720132019-03-19 Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study Feng, Chunguang Zhang, Peiying Han, Bing Li, Xianchi Liu, Yi Niu, Dongdong Shi, Yibing Medicine (Baltimore) Research Article The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated. To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of the stent treatment failure. A total of 70 patients with drug-eluting ISR undergoing OCT were enrolled (intimal hyperplasia ≥50% of stent area) and implanted with drug-eluting stents. According to stent implantation time, the patients were divided into 2 groups: early in-stent restenosis group (E-ISR group) (group A, n = 35, stent age ≤12 months) and late in-stent restenosis group (L-ISR group) (group B, n = 35, stent age ≥24 months). A qualitative analysis of the restenosis tissue included the nature of restenosis tissue (homogeneous and heterogeneous), neoatherosclerosis, thin-cap fibroatheroma (TCFA), and microvessels. The ratio of ≥75% cross-sectional area stenosis between the L-ISR and E-ISR groups was (60.00% vs 34.28%, P < .05). The heterogeneous intima, neoatherosclerosis, TCFA, and microvessels were more prevalent in the L-ISR group as compared to the E-ISR group (71.43% vs 45.71%, P < .05; 48.57% vs 22.86%, P < .05; 25.71% vs 5.71%, P < .05; 22.86% vs 2.86%, P < .05, respectively). The morphological characteristics of L-ISR were significantly different from those in the E-ISR; the former was closer to the atherosclerotic plaque, which provided a new approach for the treatment of drug-eluting ISR. Wolters Kluwer Health 2018-08-24 /pmc/articles/PMC6372013/ /pubmed/30142870 http://dx.doi.org/10.1097/MD.0000000000012117 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0fla. |
spellingShingle | Research Article Feng, Chunguang Zhang, Peiying Han, Bing Li, Xianchi Liu, Yi Niu, Dongdong Shi, Yibing Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study |
title | Optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: A STROBE compliant study |
title_full | Optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: A STROBE compliant study |
title_fullStr | Optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: A STROBE compliant study |
title_full_unstemmed | Optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: A STROBE compliant study |
title_short | Optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: A STROBE compliant study |
title_sort | optical coherence tomographic analysis of drug-eluting in-stent restenosis at
different times: a strobe compliant study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372013/ https://www.ncbi.nlm.nih.gov/pubmed/30142870 http://dx.doi.org/10.1097/MD.0000000000012117 |
work_keys_str_mv | AT fengchunguang opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT zhangpeiying opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT hanbing opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT lixianchi opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT liuyi opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT niudongdong opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy AT shiyibing opticalcoherencetomographicanalysisofdrugelutinginstentrestenosisatdifferenttimesastrobecompliantstudy |