Cargando…

Advantages offered by the double magnetic loops versus the conventional single ones

Due to their simplicity and operating mode, magnetic loops are one of the most used traffic sensors in Intelligent Transportation Systems (ITS). However, at this moment, their potential is not being fully exploited, as neither the speed nor the length of the vehicles can be surely ascertained with t...

Descripción completa

Detalles Bibliográficos
Autores principales: Mocholí Belenguer, Ferran, Mocholí Salcedo, Antonio, Guill Ibañez, Antonio, Milián Sánchez, Victor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372151/
https://www.ncbi.nlm.nih.gov/pubmed/30753200
http://dx.doi.org/10.1371/journal.pone.0211626
_version_ 1783394688704708608
author Mocholí Belenguer, Ferran
Mocholí Salcedo, Antonio
Guill Ibañez, Antonio
Milián Sánchez, Victor
author_facet Mocholí Belenguer, Ferran
Mocholí Salcedo, Antonio
Guill Ibañez, Antonio
Milián Sánchez, Victor
author_sort Mocholí Belenguer, Ferran
collection PubMed
description Due to their simplicity and operating mode, magnetic loops are one of the most used traffic sensors in Intelligent Transportation Systems (ITS). However, at this moment, their potential is not being fully exploited, as neither the speed nor the length of the vehicles can be surely ascertained with the use of a single magnetic loop. In this way, nowadays the vast majority of them are only being used to measure traffic flow and count vehicles on urban and interurban roads. This is the reason why we presented in a previous paper the double magnetic loop, capable of improving the features and functionalities of the conventional single loop without increasing the cost or introducing additional complexity. In that paper, it was introduced their design and peculiarities, how to calculate their magnetic field and three different methods to calculate their inductance. Therefore, with the purpose of improving the existing infrastructure and providing it with greater potential and reliability, this paper will focus on justifying and demonstrating the advantages offered by these double loops versus the conventional ones. This will involve analyzing the magnetic profiles generated by the passage of vehicles over double loops and comparing them with those already known. Moreover, it will be shown how the vehicle speed, the traffic direction and many other data can be obtained more easily and with less margin of error by using these new inductance signatures.
format Online
Article
Text
id pubmed-6372151
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-63721512019-03-01 Advantages offered by the double magnetic loops versus the conventional single ones Mocholí Belenguer, Ferran Mocholí Salcedo, Antonio Guill Ibañez, Antonio Milián Sánchez, Victor PLoS One Research Article Due to their simplicity and operating mode, magnetic loops are one of the most used traffic sensors in Intelligent Transportation Systems (ITS). However, at this moment, their potential is not being fully exploited, as neither the speed nor the length of the vehicles can be surely ascertained with the use of a single magnetic loop. In this way, nowadays the vast majority of them are only being used to measure traffic flow and count vehicles on urban and interurban roads. This is the reason why we presented in a previous paper the double magnetic loop, capable of improving the features and functionalities of the conventional single loop without increasing the cost or introducing additional complexity. In that paper, it was introduced their design and peculiarities, how to calculate their magnetic field and three different methods to calculate their inductance. Therefore, with the purpose of improving the existing infrastructure and providing it with greater potential and reliability, this paper will focus on justifying and demonstrating the advantages offered by these double loops versus the conventional ones. This will involve analyzing the magnetic profiles generated by the passage of vehicles over double loops and comparing them with those already known. Moreover, it will be shown how the vehicle speed, the traffic direction and many other data can be obtained more easily and with less margin of error by using these new inductance signatures. Public Library of Science 2019-02-12 /pmc/articles/PMC6372151/ /pubmed/30753200 http://dx.doi.org/10.1371/journal.pone.0211626 Text en © 2019 Mocholí Belenguer et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mocholí Belenguer, Ferran
Mocholí Salcedo, Antonio
Guill Ibañez, Antonio
Milián Sánchez, Victor
Advantages offered by the double magnetic loops versus the conventional single ones
title Advantages offered by the double magnetic loops versus the conventional single ones
title_full Advantages offered by the double magnetic loops versus the conventional single ones
title_fullStr Advantages offered by the double magnetic loops versus the conventional single ones
title_full_unstemmed Advantages offered by the double magnetic loops versus the conventional single ones
title_short Advantages offered by the double magnetic loops versus the conventional single ones
title_sort advantages offered by the double magnetic loops versus the conventional single ones
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372151/
https://www.ncbi.nlm.nih.gov/pubmed/30753200
http://dx.doi.org/10.1371/journal.pone.0211626
work_keys_str_mv AT mocholibelenguerferran advantagesofferedbythedoublemagneticloopsversustheconventionalsingleones
AT mocholisalcedoantonio advantagesofferedbythedoublemagneticloopsversustheconventionalsingleones
AT guillibanezantonio advantagesofferedbythedoublemagneticloopsversustheconventionalsingleones
AT miliansanchezvictor advantagesofferedbythedoublemagneticloopsversustheconventionalsingleones