Cargando…

Comparison of two different intraosseous access methods in a physician-staffed helicopter emergency medical service – a quality assurance study

BACKGROUND: Intravenous access in critically ill and injured patients can be difficult or impossible in the field. Intraosseous access is a well-established alternative to achieve access to a noncollapsible vascular network. We wanted to compare the use of a sternal and tibial/humeral intraosseous d...

Descripción completa

Detalles Bibliográficos
Autores principales: Sørgjerd, Renate, Sunde, Geir Arne, Heltne, Jon-Kenneth
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373167/
https://www.ncbi.nlm.nih.gov/pubmed/30760297
http://dx.doi.org/10.1186/s13049-019-0594-6
Descripción
Sumario:BACKGROUND: Intravenous access in critically ill and injured patients can be difficult or impossible in the field. Intraosseous access is a well-established alternative to achieve access to a noncollapsible vascular network. We wanted to compare the use of a sternal and tibial/humeral intraosseous device in a physician-staffed helicopter emergency medical service. METHODS: The helicopter emergency medical service in Bergen, Norway, is equipped with two different intraosseous devices, the EZ-IO and FAST-Responder. We compared insertion time, insertion sites, flow, indication for intraosseous access, and complications between the tibial/humeral and sternal techniques. RESULTS: In 49 patients, 53 intraosseous insertions were made. The overall intraosseous rate was 1.5% (53 insertions in 3600 patients treated). The main patient categories were cardiac arrest and trauma. Overall, 93.9% of the insertions were successful on the first attempt. The median insertion time using EZ-IO was 15 s compared to 20 s using FAST-Responder. Insertion complications registered using the EZ-IO included extravasation, aspiration failure and insertion time > 30 s. Using FAST-Responder, there were reported complications such as user failure (12.5%) and insertion time > 30 s (12.5%). Regarding the flow, we found that 35.1% of the EZ-IO insertions experienced poor flow and needed a pressure bag. With FAST-Responder, the flow was reported as very good or good in 85.7%, and no insertions had poor flow. CONCLUSION: Intraosseous access seems to be a reliable rescue technique in our helicopter emergency medical service, with high insertion success rates. EZ-IO was a more rapid method in gaining vascular access compared to FAST-Responder. However, FAST-Responder may be a better method when high-flow infusion is needed. Few complications were registered with both techniques in our service.