Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation
Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Japan
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373539/ https://www.ncbi.nlm.nih.gov/pubmed/30302548 http://dx.doi.org/10.1007/s00380-018-1254-x |
_version_ | 1783395009796505600 |
---|---|
author | Pott, Alexander Petscher, Kerstin Baumhardt, Michael Stephan, Tilman Rattka, Manuel Paliskyte, Rima Bothner, Carlo Keßler, Mirjam Rottbauer, Wolfgang Dahme, Tillman |
author_facet | Pott, Alexander Petscher, Kerstin Baumhardt, Michael Stephan, Tilman Rattka, Manuel Paliskyte, Rima Bothner, Carlo Keßler, Mirjam Rottbauer, Wolfgang Dahme, Tillman |
author_sort | Pott, Alexander |
collection | PubMed |
description | Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop diameter of 15 or 20 mm. The novel spiral mapping catheter (Achieve Advance, SMC2) was designed as a true guidewire and is available, in addition to the sizes of the SMC1, as a 10-polar mapping catheter with a distal loop diameter of 25 mm. Whether these novel features of SMC2 influence procedural characteristics of Cryo-PVI in comparison to SMC1 has not been reported. In this prospective cohort study 158 patients (age 65.1 ± 12.4 years, female 39%, paroxysmal AF 60%) undergoing PVI with the 2nd generation cryoballoon were included. SMC1 was used in 57 patients (36%), whereas 101 patients (64%) underwent Cryo-PVI with the SMC2. All PVs (623/623, 100%) were isolated successfully. Mean procedure duration was 72.0 ± 18.9 min in the SMC1 group and 74.4 ± 19.1 min in the SMC2 group (p = 0.432). Mean fluoroscopy time was also not different between both study groups (SMC1 15.7 ± 6.6 min, SMC2 15.7 ± 7.3 min, p = 0.593). TTI was observed in 68.6% of pulmonary veins in the SMC1 group, whereas TTI observation rate was 82.6% in the SMC2 group (p < 0.001). Number of freezes (5.5 ± 1.5 vs. 6.5 ± 1.9; p = 0.001) and total freeze duration (14.1 ± 4.5 vs. 17.6 ± 5.6; p < 0.001) were increased in the SMC2 group. SMC2 significantly increases TTI observation rate during Cryo-PVI. Procedure duration and fluoroscopy time are similar and number of freezes and total freeze duration are increased compared to PVI with SMC1 due to decreased stability and maneuverability of SMC2. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00380-018-1254-x) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6373539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Japan |
record_format | MEDLINE/PubMed |
spelling | pubmed-63735392019-03-04 Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation Pott, Alexander Petscher, Kerstin Baumhardt, Michael Stephan, Tilman Rattka, Manuel Paliskyte, Rima Bothner, Carlo Keßler, Mirjam Rottbauer, Wolfgang Dahme, Tillman Heart Vessels Original Article Observation of the time-to-pulmonary vein isolation (TTI) by a spiral mapping catheter has emerged as a valuable procedural parameter in cryoballoon pulmonary vein isolation (PVI). The 1st generation spiral mapping catheter (Achieve, SMC1) has been available as an 8-polar catheter with a distal loop diameter of 15 or 20 mm. The novel spiral mapping catheter (Achieve Advance, SMC2) was designed as a true guidewire and is available, in addition to the sizes of the SMC1, as a 10-polar mapping catheter with a distal loop diameter of 25 mm. Whether these novel features of SMC2 influence procedural characteristics of Cryo-PVI in comparison to SMC1 has not been reported. In this prospective cohort study 158 patients (age 65.1 ± 12.4 years, female 39%, paroxysmal AF 60%) undergoing PVI with the 2nd generation cryoballoon were included. SMC1 was used in 57 patients (36%), whereas 101 patients (64%) underwent Cryo-PVI with the SMC2. All PVs (623/623, 100%) were isolated successfully. Mean procedure duration was 72.0 ± 18.9 min in the SMC1 group and 74.4 ± 19.1 min in the SMC2 group (p = 0.432). Mean fluoroscopy time was also not different between both study groups (SMC1 15.7 ± 6.6 min, SMC2 15.7 ± 7.3 min, p = 0.593). TTI was observed in 68.6% of pulmonary veins in the SMC1 group, whereas TTI observation rate was 82.6% in the SMC2 group (p < 0.001). Number of freezes (5.5 ± 1.5 vs. 6.5 ± 1.9; p = 0.001) and total freeze duration (14.1 ± 4.5 vs. 17.6 ± 5.6; p < 0.001) were increased in the SMC2 group. SMC2 significantly increases TTI observation rate during Cryo-PVI. Procedure duration and fluoroscopy time are similar and number of freezes and total freeze duration are increased compared to PVI with SMC1 due to decreased stability and maneuverability of SMC2. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00380-018-1254-x) contains supplementary material, which is available to authorized users. Springer Japan 2018-10-09 2019 /pmc/articles/PMC6373539/ /pubmed/30302548 http://dx.doi.org/10.1007/s00380-018-1254-x Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Pott, Alexander Petscher, Kerstin Baumhardt, Michael Stephan, Tilman Rattka, Manuel Paliskyte, Rima Bothner, Carlo Keßler, Mirjam Rottbauer, Wolfgang Dahme, Tillman Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title | Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title_full | Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title_fullStr | Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title_full_unstemmed | Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title_short | Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
title_sort | novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373539/ https://www.ncbi.nlm.nih.gov/pubmed/30302548 http://dx.doi.org/10.1007/s00380-018-1254-x |
work_keys_str_mv | AT pottalexander novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT petscherkerstin novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT baumhardtmichael novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT stephantilman novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT rattkamanuel novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT paliskyterima novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT bothnercarlo novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT keßlermirjam novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT rottbauerwolfgang novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation AT dahmetillman novelspiralmappingcatheterfacilitatesobservationofthetimetopulmonaryveinisolationduringcryoballoonablation |