Cargando…

The accuracy of digital templating in uncemented total hip arthroplasty

INTRODUCTION: Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Al...

Descripción completa

Detalles Bibliográficos
Autores principales: Holzer, Lukas A., Scholler, Georg, Wagner, Stefan, Friesenbichler, Jörg, Maurer-Ertl, Werner, Leithner, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373540/
https://www.ncbi.nlm.nih.gov/pubmed/30523444
http://dx.doi.org/10.1007/s00402-018-3080-0
_version_ 1783395010038726656
author Holzer, Lukas A.
Scholler, Georg
Wagner, Stefan
Friesenbichler, Jörg
Maurer-Ertl, Werner
Leithner, Andreas
author_facet Holzer, Lukas A.
Scholler, Georg
Wagner, Stefan
Friesenbichler, Jörg
Maurer-Ertl, Werner
Leithner, Andreas
author_sort Holzer, Lukas A.
collection PubMed
description INTRODUCTION: Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Although the conversion to picture archiving and communication system had many positive effects, there are still problems that have to be taken into consideration. OBJECTIVES: The core objective was to evaluate the impact of the planners’ experience on the accuracy of predicting component size in digital preoperative templating of THA. In addition, the influence of overweight and obesity (according to WHO-criteria), patient’s sex and component design on the accuracy of preoperative planning have been analysed. MATERIALS AND METHODS: The retrospective study included 632 consecutive patients who had primary uncemented THA. Digital templating was done using “syngo—EndoMap” software by Siemens Medical Solutions AG. Mann–Whitney U test and Kruskal–Wallis test have been used for statistical analysis. The accuracy of predicting component size has been evaluated by comparing preoperative planned sizes with implanted sizes as documented by the surgeons. The planner’s experience was tested by comparing the reliability of preoperative planning done by senior surgeons or residents. The influence of BMI on predicting component size has been tested by comparing the accuracy of digital templating between different groups of BMI according to WHO-criteria. The same procedure has been done for evaluating the impact of patient´s sex and component design. RESULTS: The implant size was predicted exactly in 42% for the femoral and in 37% for the acetabular component. 87% of the femoral components and 78% of the acetabular cups were accurate within one size. Digital templating of femoral implant size was significantly more reliable when done by a senior surgeon. No difference was found for the acetabular component sizes. The BMI also had an impact on estimating the correct femoral implant size. In overweight patients, planning was significantly more inaccurate than normal weight people. Differences were seen in obese patients. However, these were not significant. Accuracy of acetabular components was not affected. The design of the prostheses and the patient’s sex had no influence on predicting component size. CONCLUSIONS: Inexperience and overweight are factors that correlate with inaccuracy of preoperative digital templating in femoral components, whereas acetabular components seem to be independent of these factors.
format Online
Article
Text
id pubmed-6373540
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-63735402019-03-04 The accuracy of digital templating in uncemented total hip arthroplasty Holzer, Lukas A. Scholler, Georg Wagner, Stefan Friesenbichler, Jörg Maurer-Ertl, Werner Leithner, Andreas Arch Orthop Trauma Surg Hip Arthroplasty INTRODUCTION: Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Although the conversion to picture archiving and communication system had many positive effects, there are still problems that have to be taken into consideration. OBJECTIVES: The core objective was to evaluate the impact of the planners’ experience on the accuracy of predicting component size in digital preoperative templating of THA. In addition, the influence of overweight and obesity (according to WHO-criteria), patient’s sex and component design on the accuracy of preoperative planning have been analysed. MATERIALS AND METHODS: The retrospective study included 632 consecutive patients who had primary uncemented THA. Digital templating was done using “syngo—EndoMap” software by Siemens Medical Solutions AG. Mann–Whitney U test and Kruskal–Wallis test have been used for statistical analysis. The accuracy of predicting component size has been evaluated by comparing preoperative planned sizes with implanted sizes as documented by the surgeons. The planner’s experience was tested by comparing the reliability of preoperative planning done by senior surgeons or residents. The influence of BMI on predicting component size has been tested by comparing the accuracy of digital templating between different groups of BMI according to WHO-criteria. The same procedure has been done for evaluating the impact of patient´s sex and component design. RESULTS: The implant size was predicted exactly in 42% for the femoral and in 37% for the acetabular component. 87% of the femoral components and 78% of the acetabular cups were accurate within one size. Digital templating of femoral implant size was significantly more reliable when done by a senior surgeon. No difference was found for the acetabular component sizes. The BMI also had an impact on estimating the correct femoral implant size. In overweight patients, planning was significantly more inaccurate than normal weight people. Differences were seen in obese patients. However, these were not significant. Accuracy of acetabular components was not affected. The design of the prostheses and the patient’s sex had no influence on predicting component size. CONCLUSIONS: Inexperience and overweight are factors that correlate with inaccuracy of preoperative digital templating in femoral components, whereas acetabular components seem to be independent of these factors. Springer Berlin Heidelberg 2018-12-06 2019 /pmc/articles/PMC6373540/ /pubmed/30523444 http://dx.doi.org/10.1007/s00402-018-3080-0 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Hip Arthroplasty
Holzer, Lukas A.
Scholler, Georg
Wagner, Stefan
Friesenbichler, Jörg
Maurer-Ertl, Werner
Leithner, Andreas
The accuracy of digital templating in uncemented total hip arthroplasty
title The accuracy of digital templating in uncemented total hip arthroplasty
title_full The accuracy of digital templating in uncemented total hip arthroplasty
title_fullStr The accuracy of digital templating in uncemented total hip arthroplasty
title_full_unstemmed The accuracy of digital templating in uncemented total hip arthroplasty
title_short The accuracy of digital templating in uncemented total hip arthroplasty
title_sort accuracy of digital templating in uncemented total hip arthroplasty
topic Hip Arthroplasty
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6373540/
https://www.ncbi.nlm.nih.gov/pubmed/30523444
http://dx.doi.org/10.1007/s00402-018-3080-0
work_keys_str_mv AT holzerlukasa theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT schollergeorg theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT wagnerstefan theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT friesenbichlerjorg theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT maurerertlwerner theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT leithnerandreas theaccuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT holzerlukasa accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT schollergeorg accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT wagnerstefan accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT friesenbichlerjorg accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT maurerertlwerner accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty
AT leithnerandreas accuracyofdigitaltemplatinginuncementedtotalhiparthroplasty