Cargando…
Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis
The objective of this study was to evaluate the performance of a new version of quantusFLM®, a software tool for prediction of neonatal respiratory morbidity (NRM) by ultrasound, which incorporates a fully automated fetal lung delineation based on Deep Learning techniques. A set of 790 fetal lung ul...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374419/ https://www.ncbi.nlm.nih.gov/pubmed/30760806 http://dx.doi.org/10.1038/s41598-019-38576-w |
_version_ | 1783395143863238656 |
---|---|
author | Burgos-Artizzu, Xavier P. Perez-Moreno, Álvaro Coronado-Gutierrez, David Gratacos, Eduard Palacio, Montse |
author_facet | Burgos-Artizzu, Xavier P. Perez-Moreno, Álvaro Coronado-Gutierrez, David Gratacos, Eduard Palacio, Montse |
author_sort | Burgos-Artizzu, Xavier P. |
collection | PubMed |
description | The objective of this study was to evaluate the performance of a new version of quantusFLM®, a software tool for prediction of neonatal respiratory morbidity (NRM) by ultrasound, which incorporates a fully automated fetal lung delineation based on Deep Learning techniques. A set of 790 fetal lung ultrasound images obtained at 24 + 0–38 + 6 weeks’ gestation was evaluated. Perinatal outcomes and the occurrence of NRM were recorded. quantusFLM® version 3.0 was applied to all images to automatically delineate the fetal lung and predict NRM risk. The test was compared with the same technology but using a manual delineation of the fetal lung, and with a scenario where only gestational age was available. The software predicted NRM with a sensitivity, specificity, and positive and negative predictive value of 71.0%, 94.7%, 67.9%, and 95.4%, respectively, with an accuracy of 91.5%. The accuracy for predicting NRM obtained with the same texture analysis but using a manual delineation of the lung was 90.3%, and using only gestational age was 75.6%. To sum up, automated and non-invasive software predicted NRM with a performance similar to that reported for tests based on amniotic fluid analysis and much greater than that of gestational age alone. |
format | Online Article Text |
id | pubmed-6374419 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-63744192019-02-19 Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis Burgos-Artizzu, Xavier P. Perez-Moreno, Álvaro Coronado-Gutierrez, David Gratacos, Eduard Palacio, Montse Sci Rep Article The objective of this study was to evaluate the performance of a new version of quantusFLM®, a software tool for prediction of neonatal respiratory morbidity (NRM) by ultrasound, which incorporates a fully automated fetal lung delineation based on Deep Learning techniques. A set of 790 fetal lung ultrasound images obtained at 24 + 0–38 + 6 weeks’ gestation was evaluated. Perinatal outcomes and the occurrence of NRM were recorded. quantusFLM® version 3.0 was applied to all images to automatically delineate the fetal lung and predict NRM risk. The test was compared with the same technology but using a manual delineation of the fetal lung, and with a scenario where only gestational age was available. The software predicted NRM with a sensitivity, specificity, and positive and negative predictive value of 71.0%, 94.7%, 67.9%, and 95.4%, respectively, with an accuracy of 91.5%. The accuracy for predicting NRM obtained with the same texture analysis but using a manual delineation of the lung was 90.3%, and using only gestational age was 75.6%. To sum up, automated and non-invasive software predicted NRM with a performance similar to that reported for tests based on amniotic fluid analysis and much greater than that of gestational age alone. Nature Publishing Group UK 2019-02-13 /pmc/articles/PMC6374419/ /pubmed/30760806 http://dx.doi.org/10.1038/s41598-019-38576-w Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Burgos-Artizzu, Xavier P. Perez-Moreno, Álvaro Coronado-Gutierrez, David Gratacos, Eduard Palacio, Montse Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title | Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title_full | Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title_fullStr | Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title_full_unstemmed | Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title_short | Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
title_sort | evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374419/ https://www.ncbi.nlm.nih.gov/pubmed/30760806 http://dx.doi.org/10.1038/s41598-019-38576-w |
work_keys_str_mv | AT burgosartizzuxavierp evaluationofanimprovedtoolfornoninvasivepredictionofneonatalrespiratorymorbiditybasedonfullyautomatedfetallungultrasoundanalysis AT perezmorenoalvaro evaluationofanimprovedtoolfornoninvasivepredictionofneonatalrespiratorymorbiditybasedonfullyautomatedfetallungultrasoundanalysis AT coronadogutierrezdavid evaluationofanimprovedtoolfornoninvasivepredictionofneonatalrespiratorymorbiditybasedonfullyautomatedfetallungultrasoundanalysis AT gratacoseduard evaluationofanimprovedtoolfornoninvasivepredictionofneonatalrespiratorymorbiditybasedonfullyautomatedfetallungultrasoundanalysis AT palaciomontse evaluationofanimprovedtoolfornoninvasivepredictionofneonatalrespiratorymorbiditybasedonfullyautomatedfetallungultrasoundanalysis |