Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study
BACKGROUND: Having mobile devices that provide patients with the ability to record and monitor the electrical activity of their heart enhances patient self-care and the early detection of irregular heartbeat (cardiac arrhythmia), yet few such devices exist in Vietnam. Challenges exist for introducin...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374732/ https://www.ncbi.nlm.nih.gov/pubmed/30702440 http://dx.doi.org/10.2196/resprot.8762 |
_version_ | 1783395227962179584 |
---|---|
author | Kilimo, Precious J Le, Tai Phan, Ngoc T Han, Huy-Dung Hoang, Hoc T Vu, Nguyen C Pham, Nga TT Cao, Hung Nguyen, Cuong K |
author_facet | Kilimo, Precious J Le, Tai Phan, Ngoc T Han, Huy-Dung Hoang, Hoc T Vu, Nguyen C Pham, Nga TT Cao, Hung Nguyen, Cuong K |
author_sort | Kilimo, Precious J |
collection | PubMed |
description | BACKGROUND: Having mobile devices that provide patients with the ability to record and monitor the electrical activity of their heart enhances patient self-care and the early detection of irregular heartbeat (cardiac arrhythmia), yet few such devices exist in Vietnam. Challenges exist for introducing mobile electrocardiography (ECG) monitoring devices in Vietnam, including patient accessibility and affordability. A low-cost mobile ECG monitoring device designed and developed in Vietnam, which allows patients to easily measure their heart’s electrical activity and navigate recordings, may be a solution. OBJECTIVE: The aim of this project is to assess the usability of the MD-Link system, a newly developed mobile handheld 1-lead ECG device, in detecting patients with irregular heartbeat. We will compare its outputs to the standard printed outputs of a 12-lead electrocardiogram generated by the Nihon Kohden Cardiofax S Electrocardiograph Model ECG-1250K. METHODS: We will conduct a cross-sectional study in two stages, including the measurement of ECG signals of patients using the MD-Link and the Nihon Kohden Cardiofax S and analysis of the selected standard outputs collected from the ECG recordings of the MD-Link and the Nihon Kohden Cardiofax S. The MD-Link consists of (1) a mobile device (eg, a smartphone); (2) a lead wire with 2 disposable electrodes; and (3) an easy-to-use mobile app interface enabling the upload and accurate display of ECG recordings to patients and their clinicians. Our research team, consisting of members from Dartmouth College; the Institute of Health, Population and Development; Hanoi University of Science and Technology; and physicians and nurses from Thanh Chan Clinic, will assist in carrying out this project. RESULTS: We will proceed with a publication plan that includes a project report and, ultimately, articles for peer-reviewed journals. We also hope to disseminate our work at relevant conferences to provide more coverage and exposure to the MD-Link mobile device. Recruitment and data collection were completed in January 2018. Data analysis started in February 2018 and is ongoing. Results are expected mid-2019. CONCLUSIONS: At the end of this project, we will have developed and tested the MD-Link, a low-cost mobile ECG monitoring device, with some supportive comparisons to standard ECG devices commonly used in heart clinics or hospitals in Vietnam. Our long-term goal is for the MD-Link to be easily accessible, affordable, and to fit into a patient’s daily routine, thus improving the care and treatment of patients with cardiovascular diseases (CVDs). INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/8762 |
format | Online Article Text |
id | pubmed-6374732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-63747322019-03-08 Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study Kilimo, Precious J Le, Tai Phan, Ngoc T Han, Huy-Dung Hoang, Hoc T Vu, Nguyen C Pham, Nga TT Cao, Hung Nguyen, Cuong K JMIR Res Protoc Protocol BACKGROUND: Having mobile devices that provide patients with the ability to record and monitor the electrical activity of their heart enhances patient self-care and the early detection of irregular heartbeat (cardiac arrhythmia), yet few such devices exist in Vietnam. Challenges exist for introducing mobile electrocardiography (ECG) monitoring devices in Vietnam, including patient accessibility and affordability. A low-cost mobile ECG monitoring device designed and developed in Vietnam, which allows patients to easily measure their heart’s electrical activity and navigate recordings, may be a solution. OBJECTIVE: The aim of this project is to assess the usability of the MD-Link system, a newly developed mobile handheld 1-lead ECG device, in detecting patients with irregular heartbeat. We will compare its outputs to the standard printed outputs of a 12-lead electrocardiogram generated by the Nihon Kohden Cardiofax S Electrocardiograph Model ECG-1250K. METHODS: We will conduct a cross-sectional study in two stages, including the measurement of ECG signals of patients using the MD-Link and the Nihon Kohden Cardiofax S and analysis of the selected standard outputs collected from the ECG recordings of the MD-Link and the Nihon Kohden Cardiofax S. The MD-Link consists of (1) a mobile device (eg, a smartphone); (2) a lead wire with 2 disposable electrodes; and (3) an easy-to-use mobile app interface enabling the upload and accurate display of ECG recordings to patients and their clinicians. Our research team, consisting of members from Dartmouth College; the Institute of Health, Population and Development; Hanoi University of Science and Technology; and physicians and nurses from Thanh Chan Clinic, will assist in carrying out this project. RESULTS: We will proceed with a publication plan that includes a project report and, ultimately, articles for peer-reviewed journals. We also hope to disseminate our work at relevant conferences to provide more coverage and exposure to the MD-Link mobile device. Recruitment and data collection were completed in January 2018. Data analysis started in February 2018 and is ongoing. Results are expected mid-2019. CONCLUSIONS: At the end of this project, we will have developed and tested the MD-Link, a low-cost mobile ECG monitoring device, with some supportive comparisons to standard ECG devices commonly used in heart clinics or hospitals in Vietnam. Our long-term goal is for the MD-Link to be easily accessible, affordable, and to fit into a patient’s daily routine, thus improving the care and treatment of patients with cardiovascular diseases (CVDs). INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/8762 JMIR Publications 2019-01-31 /pmc/articles/PMC6374732/ /pubmed/30702440 http://dx.doi.org/10.2196/resprot.8762 Text en ©Precious J Kilimo, Tai Le, Ngoc T Phan, Huy-Dung Han, Hoc T Hoang, Nguyen C Vu, Nga TT Pham, Hung Cao, Cuong K Nguyen. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 31.01.2019. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on http://www.researchprotocols.org, as well as this copyright and license information must be included. |
spellingShingle | Protocol Kilimo, Precious J Le, Tai Phan, Ngoc T Han, Huy-Dung Hoang, Hoc T Vu, Nguyen C Pham, Nga TT Cao, Hung Nguyen, Cuong K Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title | Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title_full | Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title_fullStr | Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title_full_unstemmed | Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title_short | Testing MD-Link, a Low-Cost Mobile Electrocardiography Monitoring Device, in Patients With Irregular Heartbeat: Protocol for a Cross-Sectional Study |
title_sort | testing md-link, a low-cost mobile electrocardiography monitoring device, in patients with irregular heartbeat: protocol for a cross-sectional study |
topic | Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374732/ https://www.ncbi.nlm.nih.gov/pubmed/30702440 http://dx.doi.org/10.2196/resprot.8762 |
work_keys_str_mv | AT kilimopreciousj testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT letai testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT phanngoct testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT hanhuydung testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT hoanghoct testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT vunguyenc testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT phamngatt testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT caohung testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy AT nguyencuongk testingmdlinkalowcostmobileelectrocardiographymonitoringdeviceinpatientswithirregularheartbeatprotocolforacrosssectionalstudy |