Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania

BACKGROUND: Hypoxia during labor contributes to 2.2 million intrapartum and early neonatal deaths each year. An additional 0.6–1.0 million cases of life-long disability occur because of fetal hypoxia during labor. It is known that fetal heart rate changes in labor correspond to hypoxia and neurologi...

Descripción completa

Detalles Bibliográficos
Autores principales: Goodman, David M., Mlay, Pendo, Thielman, Nathan, Small, Maria J., Schmitt, John W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374908/
https://www.ncbi.nlm.nih.gov/pubmed/30760224
http://dx.doi.org/10.1186/s12884-019-2212-z
_version_ 1783395261392879616
author Goodman, David M.
Mlay, Pendo
Thielman, Nathan
Small, Maria J.
Schmitt, John W.
author_facet Goodman, David M.
Mlay, Pendo
Thielman, Nathan
Small, Maria J.
Schmitt, John W.
author_sort Goodman, David M.
collection PubMed
description BACKGROUND: Hypoxia during labor contributes to 2.2 million intrapartum and early neonatal deaths each year. An additional 0.6–1.0 million cases of life-long disability occur because of fetal hypoxia during labor. It is known that fetal heart rate changes in labor correspond to hypoxia and neurologic compromise, but a reliable, low-cost method for detecting these changes is not available. In this study we sought to compare the ability of a handheld Doppler device to detect accelerations as part of the fetal scalp stimulation test and to compare the diagnostic performance of routine intermittent auscultation with auscultation that is augmented with fetal scalp stimulation. METHODS: This non-randomized, pre- and post-diagnostic trial was conducted with 568 maternal-fetus pairs at Kilimanjaro Christian Medical Center in Moshi, Tanzania. The first objective was to determine whether a handheld Doppler device could detect fetal accelerations in labor with reasonable accuracy as compared with a cardiotocography machine. We performed the fetal scalp stimulation test on 50 fetuses during labor using both a handheld Doppler and a cardiotocography machine and compared the outcomes for correlation using the kappa correlation coefficient. During the second objective, two groups of laboring women were monitored either with intermittent auscultation alone per routine protocol (N = 251) or with intermittent auscultation augmented with fetal scalp stimulation per study protocol(N = 267). Diagnostic accuracy of the monitoring method was determined by comparing umbilical cord blood gases immediately after birth with the predicted state of the baby based on monitoring. The analyses included sensitivity, specificity, and positive and negative predictive values. RESULTS: The prevalence of fetal acidemia ranged from 15 to 20%. Adding the fetal scalp stimulation test to intermittent auscultation protocols improved the performance of intermittent auscultation for detecting severe acidemia (pH < 7.0) from 27 to 70% (p = 0.032). The negative predictive value of intermittent auscultation augmented with the fetal scalp stimulation test ranged from 88 to 99% for mild (pH < 7.2) to severe fetal acidemia. CONCLUSIONS: The fetal scalp stimulation test, conducted with a handheld Doppler, is feasible and accurate in a limited resource setting. It is a low-cost solution that merits further evaluation to reduce intrapartum stillbirth and neonatal death in low-income countries. TRIAL REGISTRATION: ClinicalTrials.gov (NCT02862925).
format Online
Article
Text
id pubmed-6374908
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63749082019-02-26 Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania Goodman, David M. Mlay, Pendo Thielman, Nathan Small, Maria J. Schmitt, John W. BMC Pregnancy Childbirth Research Article BACKGROUND: Hypoxia during labor contributes to 2.2 million intrapartum and early neonatal deaths each year. An additional 0.6–1.0 million cases of life-long disability occur because of fetal hypoxia during labor. It is known that fetal heart rate changes in labor correspond to hypoxia and neurologic compromise, but a reliable, low-cost method for detecting these changes is not available. In this study we sought to compare the ability of a handheld Doppler device to detect accelerations as part of the fetal scalp stimulation test and to compare the diagnostic performance of routine intermittent auscultation with auscultation that is augmented with fetal scalp stimulation. METHODS: This non-randomized, pre- and post-diagnostic trial was conducted with 568 maternal-fetus pairs at Kilimanjaro Christian Medical Center in Moshi, Tanzania. The first objective was to determine whether a handheld Doppler device could detect fetal accelerations in labor with reasonable accuracy as compared with a cardiotocography machine. We performed the fetal scalp stimulation test on 50 fetuses during labor using both a handheld Doppler and a cardiotocography machine and compared the outcomes for correlation using the kappa correlation coefficient. During the second objective, two groups of laboring women were monitored either with intermittent auscultation alone per routine protocol (N = 251) or with intermittent auscultation augmented with fetal scalp stimulation per study protocol(N = 267). Diagnostic accuracy of the monitoring method was determined by comparing umbilical cord blood gases immediately after birth with the predicted state of the baby based on monitoring. The analyses included sensitivity, specificity, and positive and negative predictive values. RESULTS: The prevalence of fetal acidemia ranged from 15 to 20%. Adding the fetal scalp stimulation test to intermittent auscultation protocols improved the performance of intermittent auscultation for detecting severe acidemia (pH < 7.0) from 27 to 70% (p = 0.032). The negative predictive value of intermittent auscultation augmented with the fetal scalp stimulation test ranged from 88 to 99% for mild (pH < 7.2) to severe fetal acidemia. CONCLUSIONS: The fetal scalp stimulation test, conducted with a handheld Doppler, is feasible and accurate in a limited resource setting. It is a low-cost solution that merits further evaluation to reduce intrapartum stillbirth and neonatal death in low-income countries. TRIAL REGISTRATION: ClinicalTrials.gov (NCT02862925). BioMed Central 2019-02-13 /pmc/articles/PMC6374908/ /pubmed/30760224 http://dx.doi.org/10.1186/s12884-019-2212-z Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Goodman, David M.
Mlay, Pendo
Thielman, Nathan
Small, Maria J.
Schmitt, John W.
Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title_full Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title_fullStr Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title_full_unstemmed Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title_short Using fetal scalp stimulation with Doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from Tanzania
title_sort using fetal scalp stimulation with doppler ultrasonography to enhance intermittent auscultation in low-resource settings: a diagnostic trial from tanzania
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6374908/
https://www.ncbi.nlm.nih.gov/pubmed/30760224
http://dx.doi.org/10.1186/s12884-019-2212-z
work_keys_str_mv AT goodmandavidm usingfetalscalpstimulationwithdopplerultrasonographytoenhanceintermittentauscultationinlowresourcesettingsadiagnostictrialfromtanzania
AT mlaypendo usingfetalscalpstimulationwithdopplerultrasonographytoenhanceintermittentauscultationinlowresourcesettingsadiagnostictrialfromtanzania
AT thielmannathan usingfetalscalpstimulationwithdopplerultrasonographytoenhanceintermittentauscultationinlowresourcesettingsadiagnostictrialfromtanzania
AT smallmariaj usingfetalscalpstimulationwithdopplerultrasonographytoenhanceintermittentauscultationinlowresourcesettingsadiagnostictrialfromtanzania
AT schmittjohnw usingfetalscalpstimulationwithdopplerultrasonographytoenhanceintermittentauscultationinlowresourcesettingsadiagnostictrialfromtanzania