Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?

PURPOSE: Intensity Modulated Radiation Therapy (IMRT) allows for significant dose reductions to organs at risk in prostate cancer patients. However, the accurate delivery of IMRT plans can be compromised by patient positioning errors. The purpose of this study was to determine if the modeling of gra...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, X, Li, J, Schild, SE, Schild, MH, Wong, W, Vora, S, Herman, MG, Fatyga, M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6376967/
https://www.ncbi.nlm.nih.gov/pubmed/30775161
http://dx.doi.org/10.4172/2167-7964.1000302
_version_ 1783395677716348928
author Liu, X
Li, J
Schild, SE
Schild, MH
Wong, W
Vora, S
Herman, MG
Fatyga, M
author_facet Liu, X
Li, J
Schild, SE
Schild, MH
Wong, W
Vora, S
Herman, MG
Fatyga, M
author_sort Liu, X
collection PubMed
description PURPOSE: Intensity Modulated Radiation Therapy (IMRT) allows for significant dose reductions to organs at risk in prostate cancer patients. However, the accurate delivery of IMRT plans can be compromised by patient positioning errors. The purpose of this study was to determine if the modeling of grade ≥ 2 acute rectal toxicity could be used to monitor the quality of IMRT protocols. MATERIALS AND METHODS: 79 patients treated with Image and Fiducial Markers Guided IMRT (FMIGRT) and 302 patients treated with trans-abdominal ultrasound guided IMRT (USGRT) was selected for this study. Treatment plans were available for the FMIGRT group, and hand recorded dosimetric indices were available for both groups. We modeled toxicity in the FMIGRT group using the Lyman Kutcher Burman (LKB) and Univariate Logistic Regression (ULR) models, and we modeled toxicity in USGRT group using the ULR model. We performed Receiver Operating Characteristics (ROC) analysis on all of the models and compared the Area under the ROC curve (AUC) for the FMIGRT and the USGRT groups. RESULTS: The observed Incidence of grade ≥ 2 rectal toxicity was 20% in FMIGRT patients and 54% in USGRT patients. LKB model parameters in the FMIGRT group were TD(50)=56.8 Gy, slope m=0.093, and exponent n=0.131. The most predictive indices in the ULR model for the FMIGRT group were D(25%) and V(50 Gy). AUC for both models in the FMIGRT group was similar (AUC=0.67). The FMIGRT URL model predicted less than a 37% incidence of grade ≥ 2 acute rectal toxicity in the USGRT group. A fit of the ULR model to USGRT data did not yield a predictive model (AUC=0.5). CONCLUSION: Modeling of acute rectal toxicity provided a quantitative measure of the correlation between planning dosimetry and this clinical endpoint. Our study suggests that an unusually weak correlation may indicate a persistent patient positioning error.
format Online
Article
Text
id pubmed-6376967
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-63769672019-02-15 Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance? Liu, X Li, J Schild, SE Schild, MH Wong, W Vora, S Herman, MG Fatyga, M OMICS J Radiol Article PURPOSE: Intensity Modulated Radiation Therapy (IMRT) allows for significant dose reductions to organs at risk in prostate cancer patients. However, the accurate delivery of IMRT plans can be compromised by patient positioning errors. The purpose of this study was to determine if the modeling of grade ≥ 2 acute rectal toxicity could be used to monitor the quality of IMRT protocols. MATERIALS AND METHODS: 79 patients treated with Image and Fiducial Markers Guided IMRT (FMIGRT) and 302 patients treated with trans-abdominal ultrasound guided IMRT (USGRT) was selected for this study. Treatment plans were available for the FMIGRT group, and hand recorded dosimetric indices were available for both groups. We modeled toxicity in the FMIGRT group using the Lyman Kutcher Burman (LKB) and Univariate Logistic Regression (ULR) models, and we modeled toxicity in USGRT group using the ULR model. We performed Receiver Operating Characteristics (ROC) analysis on all of the models and compared the Area under the ROC curve (AUC) for the FMIGRT and the USGRT groups. RESULTS: The observed Incidence of grade ≥ 2 rectal toxicity was 20% in FMIGRT patients and 54% in USGRT patients. LKB model parameters in the FMIGRT group were TD(50)=56.8 Gy, slope m=0.093, and exponent n=0.131. The most predictive indices in the ULR model for the FMIGRT group were D(25%) and V(50 Gy). AUC for both models in the FMIGRT group was similar (AUC=0.67). The FMIGRT URL model predicted less than a 37% incidence of grade ≥ 2 acute rectal toxicity in the USGRT group. A fit of the ULR model to USGRT data did not yield a predictive model (AUC=0.5). CONCLUSION: Modeling of acute rectal toxicity provided a quantitative measure of the correlation between planning dosimetry and this clinical endpoint. Our study suggests that an unusually weak correlation may indicate a persistent patient positioning error. 2018-12-03 2018 /pmc/articles/PMC6376967/ /pubmed/30775161 http://dx.doi.org/10.4172/2167-7964.1000302 Text en http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Liu, X
Li, J
Schild, SE
Schild, MH
Wong, W
Vora, S
Herman, MG
Fatyga, M
Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title_full Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title_fullStr Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title_full_unstemmed Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title_short Modeling of Acute Rectal Toxicity to Compare Two Patient Positioning Methods for Prostate Cancer Radiotherapy: Can Toxicity Modeling be Used for Quality Assurance?
title_sort modeling of acute rectal toxicity to compare two patient positioning methods for prostate cancer radiotherapy: can toxicity modeling be used for quality assurance?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6376967/
https://www.ncbi.nlm.nih.gov/pubmed/30775161
http://dx.doi.org/10.4172/2167-7964.1000302
work_keys_str_mv AT liux modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT lij modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT schildse modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT schildmh modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT wongw modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT voras modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT hermanmg modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance
AT fatygam modelingofacuterectaltoxicitytocomparetwopatientpositioningmethodsforprostatecancerradiotherapycantoxicitymodelingbeusedforqualityassurance