Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation

Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preopera...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Neichuan, Yuan, Haiyun, Chen, Xiangyu, Liu, Jiawei, Jian, Qifei, Huang, Meiping, Zhang, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378018/
https://www.ncbi.nlm.nih.gov/pubmed/30863453
http://dx.doi.org/10.1155/2019/1502318
_version_ 1783395847395868672
author Zhang, Neichuan
Yuan, Haiyun
Chen, Xiangyu
Liu, Jiawei
Jian, Qifei
Huang, Meiping
Zhang, Kai
author_facet Zhang, Neichuan
Yuan, Haiyun
Chen, Xiangyu
Liu, Jiawei
Jian, Qifei
Huang, Meiping
Zhang, Kai
author_sort Zhang, Neichuan
collection PubMed
description Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow.
format Online
Article
Text
id pubmed-6378018
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-63780182019-03-12 Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation Zhang, Neichuan Yuan, Haiyun Chen, Xiangyu Liu, Jiawei Jian, Qifei Huang, Meiping Zhang, Kai Comput Math Methods Med Research Article Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow. Hindawi 2019-02-03 /pmc/articles/PMC6378018/ /pubmed/30863453 http://dx.doi.org/10.1155/2019/1502318 Text en Copyright © 2019 Neichuan Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Neichuan
Yuan, Haiyun
Chen, Xiangyu
Liu, Jiawei
Jian, Qifei
Huang, Meiping
Zhang, Kai
Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title_full Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title_fullStr Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title_full_unstemmed Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title_short Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
title_sort computational fluid dynamics characterization of two patient-specific systemic-to-pulmonary shunts before and after operation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378018/
https://www.ncbi.nlm.nih.gov/pubmed/30863453
http://dx.doi.org/10.1155/2019/1502318
work_keys_str_mv AT zhangneichuan computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT yuanhaiyun computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT chenxiangyu computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT liujiawei computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT jianqifei computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT huangmeiping computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation
AT zhangkai computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation