Cargando…
Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation
Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preopera...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378018/ https://www.ncbi.nlm.nih.gov/pubmed/30863453 http://dx.doi.org/10.1155/2019/1502318 |
_version_ | 1783395847395868672 |
---|---|
author | Zhang, Neichuan Yuan, Haiyun Chen, Xiangyu Liu, Jiawei Jian, Qifei Huang, Meiping Zhang, Kai |
author_facet | Zhang, Neichuan Yuan, Haiyun Chen, Xiangyu Liu, Jiawei Jian, Qifei Huang, Meiping Zhang, Kai |
author_sort | Zhang, Neichuan |
collection | PubMed |
description | Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow. |
format | Online Article Text |
id | pubmed-6378018 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-63780182019-03-12 Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation Zhang, Neichuan Yuan, Haiyun Chen, Xiangyu Liu, Jiawei Jian, Qifei Huang, Meiping Zhang, Kai Comput Math Methods Med Research Article Studying the haemodynamics of the central shunt (CS) and modified Blalock–Taussig shunt (MBTS) benefits the improvement of postoperative recovery for patients with an aorta-pulmonary shunt. Shunt configurations, including CS and MBTS, are virtually reconstructed for infants A and B based on preoperative CT data, and three-dimensional models of A, 11 months after CS, and B, 8 months after MBTS, are reconstructed based on postoperative CT data. A series of parameters including energy loss, wall shear stress, and shunt ratio are computed from simulation to analyse the haemodynamics of CS and MBTS. Our results showed that the shunt ratio of the CS is approximately 30% higher than the MBTS and velocity distribution in the left pulmonary artery (LPA) and right pulmonary artery (RPA) was closer to a natural development in the CS than the MBTS. However, energy loss of the MBTS is lower, and the MBTS can provide more symmetric pulmonary artery (PA) flow than the CS. With the growth of infants A and B, the shunt ratio of infants was decreased, but maximum wall shear stress and the distribution region of high wall shear stress (WSS) were increased, which raises the probability of thrombosis. For infant A, the preoperative abnormal PA structure directly resulted in asymmetric growth of PA after operation, and the LPA/RPA ratio decreased from 0.49 to 0.25. Insufficient reserved length of the MBTS led to traction phenomena with the growth of infant B; on the one hand, it increased the eddy current, and on the other hand, it increased the flow resistance of anastomosis, promoting asymmetric PA flow. Hindawi 2019-02-03 /pmc/articles/PMC6378018/ /pubmed/30863453 http://dx.doi.org/10.1155/2019/1502318 Text en Copyright © 2019 Neichuan Zhang et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Zhang, Neichuan Yuan, Haiyun Chen, Xiangyu Liu, Jiawei Jian, Qifei Huang, Meiping Zhang, Kai Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title | Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title_full | Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title_fullStr | Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title_full_unstemmed | Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title_short | Computational Fluid Dynamics Characterization of Two Patient-Specific Systemic-to-Pulmonary Shunts before and after Operation |
title_sort | computational fluid dynamics characterization of two patient-specific systemic-to-pulmonary shunts before and after operation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378018/ https://www.ncbi.nlm.nih.gov/pubmed/30863453 http://dx.doi.org/10.1155/2019/1502318 |
work_keys_str_mv | AT zhangneichuan computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT yuanhaiyun computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT chenxiangyu computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT liujiawei computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT jianqifei computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT huangmeiping computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation AT zhangkai computationalfluiddynamicscharacterizationoftwopatientspecificsystemictopulmonaryshuntsbeforeandafteroperation |