Cargando…
Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH
BACKGROUND: Pleural fluid pH is an essential test for diagnosing complicated parapneumonic effusion. We evaluated the performance of two blood gas analyzers in measuring pleural fluid pH. METHODS: The i-STAT G3+ (Abbott) was used as a reference analyzer to evaluate the pH values obtained from other...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378778/ https://www.ncbi.nlm.nih.gov/pubmed/30815526 http://dx.doi.org/10.1016/j.plabm.2019.e00117 |
_version_ | 1783395987110232064 |
---|---|
author | Cho, Jooyoung Kim, Young Sam Kim, Young Hwan Lee, Jae-Yeon Bae, In Cheol Lee, Sang-Guk Kim, Jeong-Ho |
author_facet | Cho, Jooyoung Kim, Young Sam Kim, Young Hwan Lee, Jae-Yeon Bae, In Cheol Lee, Sang-Guk Kim, Jeong-Ho |
author_sort | Cho, Jooyoung |
collection | PubMed |
description | BACKGROUND: Pleural fluid pH is an essential test for diagnosing complicated parapneumonic effusion. We evaluated the performance of two blood gas analyzers in measuring pleural fluid pH. METHODS: The i-STAT G3+ (Abbott) was used as a reference analyzer to evaluate the pH values obtained from other methods: the i-Smart 300 (i-SENS), the pHOx Ultra (Nova Biomedical), using a clot catcher to filter off microclot, and pH indicator paper. Within-device precision was performed using quality control materials. We compared pleural fluid pH (n = 86) by the above methods and analyzed the concordance rate at the level of the medical decision point, pH 7.2. RESULTS: The within-device coefficient of variations of pH were below 0.1% for all blood gas analyzers tested. The slopes of the regression equations for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.850 (95% confidence interval, CI, 0.800–0.896), 0.714 (95% CI, 0.671–0.766), and 1.105 (95% CI, 0.781–1.581), respectively. The kappa values for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.883 (95% CI, 0.656–1.110), 0.739 (95% CI, 0.393–1.084), and 0.464 (95% CI, 0.102–0.826), respectively. CONCLUSIONS: The i-Smart 300 and pHOx Ultra demonstrated good analytical performance and diagnostic accuracy when determining pleural fluid pH compared with that by the i-STAT G3+, whereas the pH indicator paper showed unsatisfactory results. |
format | Online Article Text |
id | pubmed-6378778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-63787782019-02-27 Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH Cho, Jooyoung Kim, Young Sam Kim, Young Hwan Lee, Jae-Yeon Bae, In Cheol Lee, Sang-Guk Kim, Jeong-Ho Pract Lab Med Article BACKGROUND: Pleural fluid pH is an essential test for diagnosing complicated parapneumonic effusion. We evaluated the performance of two blood gas analyzers in measuring pleural fluid pH. METHODS: The i-STAT G3+ (Abbott) was used as a reference analyzer to evaluate the pH values obtained from other methods: the i-Smart 300 (i-SENS), the pHOx Ultra (Nova Biomedical), using a clot catcher to filter off microclot, and pH indicator paper. Within-device precision was performed using quality control materials. We compared pleural fluid pH (n = 86) by the above methods and analyzed the concordance rate at the level of the medical decision point, pH 7.2. RESULTS: The within-device coefficient of variations of pH were below 0.1% for all blood gas analyzers tested. The slopes of the regression equations for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.850 (95% confidence interval, CI, 0.800–0.896), 0.714 (95% CI, 0.671–0.766), and 1.105 (95% CI, 0.781–1.581), respectively. The kappa values for the i-Smart 300, pHOx Ultra, and pH indicator paper against the reference analyzer were 0.883 (95% CI, 0.656–1.110), 0.739 (95% CI, 0.393–1.084), and 0.464 (95% CI, 0.102–0.826), respectively. CONCLUSIONS: The i-Smart 300 and pHOx Ultra demonstrated good analytical performance and diagnostic accuracy when determining pleural fluid pH compared with that by the i-STAT G3+, whereas the pH indicator paper showed unsatisfactory results. Elsevier 2019-01-29 /pmc/articles/PMC6378778/ /pubmed/30815526 http://dx.doi.org/10.1016/j.plabm.2019.e00117 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Article Cho, Jooyoung Kim, Young Sam Kim, Young Hwan Lee, Jae-Yeon Bae, In Cheol Lee, Sang-Guk Kim, Jeong-Ho Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title | Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title_full | Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title_fullStr | Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title_full_unstemmed | Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title_short | Comparison of analytical performance of i-Smart 300 and pHOx ultra for the accurate determination of pleural fluid pH |
title_sort | comparison of analytical performance of i-smart 300 and phox ultra for the accurate determination of pleural fluid ph |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6378778/ https://www.ncbi.nlm.nih.gov/pubmed/30815526 http://dx.doi.org/10.1016/j.plabm.2019.e00117 |
work_keys_str_mv | AT chojooyoung comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT kimyoungsam comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT kimyounghwan comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT leejaeyeon comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT baeincheol comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT leesangguk comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph AT kimjeongho comparisonofanalyticalperformanceofismart300andphoxultrafortheaccuratedeterminationofpleuralfluidph |