Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up

BACKGROUND: This prospective cohort study reports the medium-term clinical and radiographic results of 113 hips treated with a hybrid total hip replacement (THR) with a new cemented tapered cobalt-chrome (Co-Cr) stem with a titanium (Ti) modular neck (ProfemurXm®). METHOD: Between October 2008 and D...

Descripción completa

Detalles Bibliográficos
Autores principales: Vanbiervliet, Jens, Somers, Jan F.A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380089/
https://www.ncbi.nlm.nih.gov/pubmed/28222212
http://dx.doi.org/10.5301/hipint.5000486
_version_ 1783396251205632000
author Vanbiervliet, Jens
Somers, Jan F.A.
author_facet Vanbiervliet, Jens
Somers, Jan F.A.
author_sort Vanbiervliet, Jens
collection PubMed
description BACKGROUND: This prospective cohort study reports the medium-term clinical and radiographic results of 113 hips treated with a hybrid total hip replacement (THR) with a new cemented tapered cobalt-chrome (Co-Cr) stem with a titanium (Ti) modular neck (ProfemurXm®). METHOD: Between October 2008 and December 2010 we performed 115 consecutive hybrid THR with the ProfemurXm® in 105 patients. RESULTS: Survivorship of the implant (stem and modular neck) at a mean of 6.5 years (min 5-max 8) was 100% with the endpoint revision for any reason. No implant was at risk for revision or showed signs of loosening. The mean Harris Hip Score was 89/100, mean Oxford Hip Score was 43/48, mean WOMAC was 91/100. No patient had thigh pain, no patient reported squeaking. There were no dislocations in this cohort. No implant showed development of radiolucent lines (RLL), either at the stem-cement or cement-bone interface. No hip showed osteolysis or calcar resorption. The mean femoral subsidence of the stem within the cement mantel was 0.31 mm (range 0-0.6 mm) after 6.5 years. With the use of this modular stem, 93% of hips showed no measurable leg length difference after THR, and leg length could be restored within a 5-mm limit in 99% of hips. CONCLUSIONS: The mid-term results of this new polished stem were excellent, without adverse effects from the use of modularity.
format Online
Article
Text
id pubmed-6380089
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-63800892019-06-03 Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up Vanbiervliet, Jens Somers, Jan F.A. Hip Int Original Research BACKGROUND: This prospective cohort study reports the medium-term clinical and radiographic results of 113 hips treated with a hybrid total hip replacement (THR) with a new cemented tapered cobalt-chrome (Co-Cr) stem with a titanium (Ti) modular neck (ProfemurXm®). METHOD: Between October 2008 and December 2010 we performed 115 consecutive hybrid THR with the ProfemurXm® in 105 patients. RESULTS: Survivorship of the implant (stem and modular neck) at a mean of 6.5 years (min 5-max 8) was 100% with the endpoint revision for any reason. No implant was at risk for revision or showed signs of loosening. The mean Harris Hip Score was 89/100, mean Oxford Hip Score was 43/48, mean WOMAC was 91/100. No patient had thigh pain, no patient reported squeaking. There were no dislocations in this cohort. No implant showed development of radiolucent lines (RLL), either at the stem-cement or cement-bone interface. No hip showed osteolysis or calcar resorption. The mean femoral subsidence of the stem within the cement mantel was 0.31 mm (range 0-0.6 mm) after 6.5 years. With the use of this modular stem, 93% of hips showed no measurable leg length difference after THR, and leg length could be restored within a 5-mm limit in 99% of hips. CONCLUSIONS: The mid-term results of this new polished stem were excellent, without adverse effects from the use of modularity. SAGE Publications 2017-02-18 2017-09 /pmc/articles/PMC6380089/ /pubmed/28222212 http://dx.doi.org/10.5301/hipint.5000486 Text en © 2017 The Authors http://www.creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research
Vanbiervliet, Jens
Somers, Jan F.A.
Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title_full Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title_fullStr Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title_full_unstemmed Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title_short Excellent Mid-Term Results of a New Polished Tapered Modular Cemented Stem: A Study of 113 Hip Replacements with Minimum 5-Year Follow-Up
title_sort excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380089/
https://www.ncbi.nlm.nih.gov/pubmed/28222212
http://dx.doi.org/10.5301/hipint.5000486
work_keys_str_mv AT vanbiervlietjens excellentmidtermresultsofanewpolishedtaperedmodularcementedstemastudyof113hipreplacementswithminimum5yearfollowup
AT somersjanfa excellentmidtermresultsofanewpolishedtaperedmodularcementedstemastudyof113hipreplacementswithminimum5yearfollowup