Cargando…
Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging
To evaluate iterative metal artifact reduction (iMAR) technique in images data of hip prosthesis on computed tomography (CT) and the added value of advanced modeled iterative reconstruction (ADMIRE) compared with standard filtered back projection (FBP). Twenty-eight patients addressed to CT examinat...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380676/ https://www.ncbi.nlm.nih.gov/pubmed/30732160 http://dx.doi.org/10.1097/MD.0000000000014341 |
_version_ | 1783396336337420288 |
---|---|
author | Neroladaki, Angeliki Martin, Steve Philippe Bagetakos, Ilias Botsikas, Diomidis Hamard, Marion Montet, Xavier Boudabbous, Sana |
author_facet | Neroladaki, Angeliki Martin, Steve Philippe Bagetakos, Ilias Botsikas, Diomidis Hamard, Marion Montet, Xavier Boudabbous, Sana |
author_sort | Neroladaki, Angeliki |
collection | PubMed |
description | To evaluate iterative metal artifact reduction (iMAR) technique in images data of hip prosthesis on computed tomography (CT) and the added value of advanced modeled iterative reconstruction (ADMIRE) compared with standard filtered back projection (FBP). Twenty-eight patients addressed to CT examinations for hip prosthesis were included prospectively. Images were reconstructed with iMAR algorithm in addition to FBP and ADMIRE techniques. Measuring image noise assessed objective image quality and attenuation values with standardized region of interest (ROI) in 4 predefined anatomical structures (gluteus medius and rectus femoris muscles, inferior and anterior abdominal fat, and femoral vessels when contrast media was present). Subjective image quality was graded on a 5-point Likert scale, taking into account the size of artifacts, the metal–bone interface and the conspicuity of pelvic organs, and the diagnostic confidence. Improvement in overall image quality was statistically significant using iMAR (P<.001) compared with ADMIRE and FBP. ADMIRE did not show any impact in image noise, attenuation value, or global quality image. iMAR showed a significant decrease in image noise in all ROIs (Hounsfield Unit) as compared with FBP and ADMIRE. Interobserver agreement was high in all reconstructions (FBP, FBP+iMAR, ADMIRE, and ADMIRE + iMAR) more than 0.8. iMAR reconstructions showed emergence of new artifacts in bone–metal interface. iMAR algorithm allows a significant reduction of metal artifacts on CT images with unilateral or bilateral prostheses without additional value of ADMIRE. It improves the analysis of surrounding tissue but potentially generates new artifacts in bone–metal interface. |
format | Online Article Text |
id | pubmed-6380676 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-63806762019-03-04 Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging Neroladaki, Angeliki Martin, Steve Philippe Bagetakos, Ilias Botsikas, Diomidis Hamard, Marion Montet, Xavier Boudabbous, Sana Medicine (Baltimore) Research Article To evaluate iterative metal artifact reduction (iMAR) technique in images data of hip prosthesis on computed tomography (CT) and the added value of advanced modeled iterative reconstruction (ADMIRE) compared with standard filtered back projection (FBP). Twenty-eight patients addressed to CT examinations for hip prosthesis were included prospectively. Images were reconstructed with iMAR algorithm in addition to FBP and ADMIRE techniques. Measuring image noise assessed objective image quality and attenuation values with standardized region of interest (ROI) in 4 predefined anatomical structures (gluteus medius and rectus femoris muscles, inferior and anterior abdominal fat, and femoral vessels when contrast media was present). Subjective image quality was graded on a 5-point Likert scale, taking into account the size of artifacts, the metal–bone interface and the conspicuity of pelvic organs, and the diagnostic confidence. Improvement in overall image quality was statistically significant using iMAR (P<.001) compared with ADMIRE and FBP. ADMIRE did not show any impact in image noise, attenuation value, or global quality image. iMAR showed a significant decrease in image noise in all ROIs (Hounsfield Unit) as compared with FBP and ADMIRE. Interobserver agreement was high in all reconstructions (FBP, FBP+iMAR, ADMIRE, and ADMIRE + iMAR) more than 0.8. iMAR reconstructions showed emergence of new artifacts in bone–metal interface. iMAR algorithm allows a significant reduction of metal artifacts on CT images with unilateral or bilateral prostheses without additional value of ADMIRE. It improves the analysis of surrounding tissue but potentially generates new artifacts in bone–metal interface. Wolters Kluwer Health 2019-02-08 /pmc/articles/PMC6380676/ /pubmed/30732160 http://dx.doi.org/10.1097/MD.0000000000014341 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | Research Article Neroladaki, Angeliki Martin, Steve Philippe Bagetakos, Ilias Botsikas, Diomidis Hamard, Marion Montet, Xavier Boudabbous, Sana Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title | Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title_full | Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title_fullStr | Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title_full_unstemmed | Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title_short | Metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
title_sort | metallic artifact reduction by evaluation of the additional value of iterative reconstruction algorithms in hip prosthesis computed tomography imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6380676/ https://www.ncbi.nlm.nih.gov/pubmed/30732160 http://dx.doi.org/10.1097/MD.0000000000014341 |
work_keys_str_mv | AT neroladakiangeliki metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT martinstevephilippe metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT bagetakosilias metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT botsikasdiomidis metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT hamardmarion metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT montetxavier metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging AT boudabboussana metallicartifactreductionbyevaluationoftheadditionalvalueofiterativereconstructionalgorithmsinhipprosthesiscomputedtomographyimaging |