Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)

INTRODUCTION: Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devic...

Descripción completa

Detalles Bibliográficos
Autores principales: Jarrahian, Courtney, Rein-Weston, Annie, Saxon, Gene, Creelman, Ben, Kachmarik, Greg, Anand, Abhijeet, Zehrung, Darin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6381447/
https://www.ncbi.nlm.nih.gov/pubmed/28189403
http://dx.doi.org/10.1016/j.vaccine.2016.11.098
_version_ 1783396495579414528
author Jarrahian, Courtney
Rein-Weston, Annie
Saxon, Gene
Creelman, Ben
Kachmarik, Greg
Anand, Abhijeet
Zehrung, Darin
author_facet Jarrahian, Courtney
Rein-Weston, Annie
Saxon, Gene
Creelman, Ben
Kachmarik, Greg
Anand, Abhijeet
Zehrung, Darin
author_sort Jarrahian, Courtney
collection PubMed
description INTRODUCTION: Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. METHODS: Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. RESULTS: Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. DISCUSSION: If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered.
format Online
Article
Text
id pubmed-6381447
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier Science
record_format MEDLINE/PubMed
spelling pubmed-63814472019-02-28 Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV) Jarrahian, Courtney Rein-Weston, Annie Saxon, Gene Creelman, Ben Kachmarik, Greg Anand, Abhijeet Zehrung, Darin Vaccine Article INTRODUCTION: Intradermal delivery of a fractional dose of inactivated poliovirus vaccine (IPV) offers potential benefits compared to intramuscular (IM) delivery, including possible cost reductions and easing of IPV supply shortages. Objectives of this study were to assess intradermal delivery devices for dead space, wastage generated by the filling process, dose accuracy, and total number of doses that can be delivered per vial. METHODS: Devices tested included syringes with staked (fixed) needles (autodisable syringes and syringes used with intradermal adapters), a luer-slip needle and syringe, a mini-needle syringe, a hollow microneedle device, and disposable-syringe jet injectors with their associated filling adapters. Each device was used to withdraw 0.1-mL fractional doses from single-dose IM glass vials which were then ejected into a beaker. Both vial and device were weighed before and after filling and again after expulsion of liquid to record change in volume at each stage of the process. Data were used to calculate the number of doses that could potentially be obtained from multidose vials. RESULTS: Results show wide variability in dead space, dose accuracy, overall wastage, and total number of doses that can be obtained per vial among intradermal delivery devices. Syringes with staked needles had relatively low dead space and low overall wastage, and could achieve a greater number of doses per vial compared to syringes with a detachable luer-slip needle. Of the disposable-syringe jet injectors tested, one was comparable to syringes with staked needles. DISCUSSION: If intradermal delivery of IPV is introduced, selection of an intradermal delivery device can have a substantial impact on vaccine wasted during administration, and thus on the required quantity of vaccine that needs to be purchased. An ideal intradermal delivery device should be not only safe, reliable, accurate, and acceptable to users and vaccine recipients, but should also have low dead space, high dose accuracy, and low overall wastage to maximize the potential number of doses that can be withdrawn and delivered. Elsevier Science 2017-03-27 /pmc/articles/PMC6381447/ /pubmed/28189403 http://dx.doi.org/10.1016/j.vaccine.2016.11.098 Text en © 2017 PATH http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jarrahian, Courtney
Rein-Weston, Annie
Saxon, Gene
Creelman, Ben
Kachmarik, Greg
Anand, Abhijeet
Zehrung, Darin
Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title_full Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title_fullStr Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title_full_unstemmed Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title_short Vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (IPV)
title_sort vial usage, device dead space, vaccine wastage, and dose accuracy of intradermal delivery devices for inactivated poliovirus vaccine (ipv)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6381447/
https://www.ncbi.nlm.nih.gov/pubmed/28189403
http://dx.doi.org/10.1016/j.vaccine.2016.11.098
work_keys_str_mv AT jarrahiancourtney vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT reinwestonannie vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT saxongene vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT creelmanben vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT kachmarikgreg vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT anandabhijeet vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv
AT zehrungdarin vialusagedevicedeadspacevaccinewastageanddoseaccuracyofintradermaldeliverydevicesforinactivatedpoliovirusvaccineipv