Cargando…

ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments

BACKGROUND: The investigation of intracellular metabolism is the mainstay in the biotechnology and physiology settings. Intracellular metabolic rates are commonly evaluated using labeling pattern of the identified metabolites obtained from stable isotope labeling experiments. The labeling pattern or...

Descripción completa

Detalles Bibliográficos
Autores principales: Du, Di, Tan, Lin, Wang, Yumeng, Peng, Bo, Weinstein, John N., Wondisford, Fredric E., Su, Xiaoyang, Lorenzi, Philip L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6381631/
https://www.ncbi.nlm.nih.gov/pubmed/30782135
http://dx.doi.org/10.1186/s12859-019-2669-9
_version_ 1783396536772722688
author Du, Di
Tan, Lin
Wang, Yumeng
Peng, Bo
Weinstein, John N.
Wondisford, Fredric E.
Su, Xiaoyang
Lorenzi, Philip L.
author_facet Du, Di
Tan, Lin
Wang, Yumeng
Peng, Bo
Weinstein, John N.
Wondisford, Fredric E.
Su, Xiaoyang
Lorenzi, Philip L.
author_sort Du, Di
collection PubMed
description BACKGROUND: The investigation of intracellular metabolism is the mainstay in the biotechnology and physiology settings. Intracellular metabolic rates are commonly evaluated using labeling pattern of the identified metabolites obtained from stable isotope labeling experiments. The labeling pattern or mass distribution vector describes the fractional abundances of all isotopologs with different masses as a result of isotopic labeling, which are typically resolved using mass spectrometry. Because naturally occurring isotopes and isotopic impurity also contribute to measured signals, the measured patterns must be corrected to obtain the labeling patterns. Since contaminant isotopologs with the same nominal mass can be resolved using modern mass spectrometers with high mass resolution, the correction process should be resolution dependent. RESULTS: Here we present a software tool, ElemCor, to perform correction of such data in a resolution-dependent manner. The tool is based on mass difference theory (MDT) and information from unlabeled samples (ULS) to account for resolution effects. MDT is a mathematical theory and only requires chemical formulae to perform correction. ULS is semi-empirical and requires additional measurement of isotopologs from unlabeled samples. We validate both methods and show their improvement in accuracy and comprehensiveness over existing methods using simulated data and experimental data from Saccharomyces cerevisiae. The tool is available at https://github.com/4dsoftware/elemcor. CONCLUSIONS: We present a software tool based on two methods, MDT and ULS, to correct LC-MS data from isotopic labeling experiments for natural abundance and isotopic impurity. We recommend MDT for low-mass compounds for cost efficiency in experiments, and ULS for high-mass compounds with relatively large spectral inaccuracy that can be tracked by unlabeled standards.
format Online
Article
Text
id pubmed-6381631
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-63816312019-02-28 ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments Du, Di Tan, Lin Wang, Yumeng Peng, Bo Weinstein, John N. Wondisford, Fredric E. Su, Xiaoyang Lorenzi, Philip L. BMC Bioinformatics Research Article BACKGROUND: The investigation of intracellular metabolism is the mainstay in the biotechnology and physiology settings. Intracellular metabolic rates are commonly evaluated using labeling pattern of the identified metabolites obtained from stable isotope labeling experiments. The labeling pattern or mass distribution vector describes the fractional abundances of all isotopologs with different masses as a result of isotopic labeling, which are typically resolved using mass spectrometry. Because naturally occurring isotopes and isotopic impurity also contribute to measured signals, the measured patterns must be corrected to obtain the labeling patterns. Since contaminant isotopologs with the same nominal mass can be resolved using modern mass spectrometers with high mass resolution, the correction process should be resolution dependent. RESULTS: Here we present a software tool, ElemCor, to perform correction of such data in a resolution-dependent manner. The tool is based on mass difference theory (MDT) and information from unlabeled samples (ULS) to account for resolution effects. MDT is a mathematical theory and only requires chemical formulae to perform correction. ULS is semi-empirical and requires additional measurement of isotopologs from unlabeled samples. We validate both methods and show their improvement in accuracy and comprehensiveness over existing methods using simulated data and experimental data from Saccharomyces cerevisiae. The tool is available at https://github.com/4dsoftware/elemcor. CONCLUSIONS: We present a software tool based on two methods, MDT and ULS, to correct LC-MS data from isotopic labeling experiments for natural abundance and isotopic impurity. We recommend MDT for low-mass compounds for cost efficiency in experiments, and ULS for high-mass compounds with relatively large spectral inaccuracy that can be tracked by unlabeled standards. BioMed Central 2019-02-19 /pmc/articles/PMC6381631/ /pubmed/30782135 http://dx.doi.org/10.1186/s12859-019-2669-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Du, Di
Tan, Lin
Wang, Yumeng
Peng, Bo
Weinstein, John N.
Wondisford, Fredric E.
Su, Xiaoyang
Lorenzi, Philip L.
ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title_full ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title_fullStr ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title_full_unstemmed ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title_short ElemCor: accurate data analysis and enrichment calculation for high-resolution LC-MS stable isotope labeling experiments
title_sort elemcor: accurate data analysis and enrichment calculation for high-resolution lc-ms stable isotope labeling experiments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6381631/
https://www.ncbi.nlm.nih.gov/pubmed/30782135
http://dx.doi.org/10.1186/s12859-019-2669-9
work_keys_str_mv AT dudi elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT tanlin elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT wangyumeng elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT pengbo elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT weinsteinjohnn elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT wondisfordfredrice elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT suxiaoyang elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments
AT lorenziphilipl elemcoraccuratedataanalysisandenrichmentcalculationforhighresolutionlcmsstableisotopelabelingexperiments