Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy?
PURPOSE: In this prospective phase II study, we investigated whether cone beam computed tomography scan was a superior method of image-guided radiotherapy relative to 2D orthogonal kilovoltage images in the post-radical prostatectomy setting. METHODS: A total of 419 treatment fractions were included...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6383090/ https://www.ncbi.nlm.nih.gov/pubmed/30782085 http://dx.doi.org/10.1177/1533033819831962 |
_version_ | 1783396775428620288 |
---|---|
author | Elakshar, Sara James, Man Git Tsui Michael, Jonathan Kucharczyk Tomic, Nada Fawaz, Ziad Simon Bahoric, Boris Papayanatos, Joseph Chaddad, Ahmad Niazi, Tamim |
author_facet | Elakshar, Sara James, Man Git Tsui Michael, Jonathan Kucharczyk Tomic, Nada Fawaz, Ziad Simon Bahoric, Boris Papayanatos, Joseph Chaddad, Ahmad Niazi, Tamim |
author_sort | Elakshar, Sara |
collection | PubMed |
description | PURPOSE: In this prospective phase II study, we investigated whether cone beam computed tomography scan was a superior method of image-guided radiotherapy relative to 2D orthogonal kilovoltage images in the post-radical prostatectomy setting. METHODS: A total of 419 treatment fractions were included in this analysis. The shifts required to align the patient for each treatment were performed using 3D matching between cone beam computed tomography scans and the corresponding computed tomography images used for planning. This was compared with the shifts obtained from 2D orthogonal kilovoltage images, matching with the corresponding digitally reconstructed radiographs. Patients did not have fiducials inserted to assist with localization. Interfractional changes in the bladder and rectal volumes were subsequently measured on the cone beam computed tomography images for each fraction and compared to the shift differences between orthogonal kilovoltage and cone beam computed tomography scans. The proportion of treatment fractions with a shift difference exceeding the planning target volume of 7 mm, between orthogonal kilovoltage and cone beam computed tomography scans, was calculated. RESULTS: The mean vertical, lateral, and longitudinal shifts resulted from 2D match between orthogonal kilovoltage images and corresponding digitally reconstructed radiographs were 0.353 cm (interquartile range: 0.1-0.5), 0.346 cm (interquartile range: 0.1-0.5), and 0.289 cm (interquartile range: 0.1-0.4), compared to 0.388 cm (interquartile range: 0.1-0.5), 0.342 cm (interquartile range: 0.1-0.5), and 0.291 cm (interquartile range: 0.1-0.4) obtained from 3D match between cone beam computed tomography and planning computed tomography scan, respectively. Our results show a significant difference between the kilovoltage and cone beam computed tomography shifts in the anterior–posterior direction (P = .01). The proportion of treatment fractions in which the differences in kilovoltage and cone beam computed tomography shifts between exceeded the 7 mm planning target volume margin was 6%, 2%, and 3% in the anterior–posterior, lateral, and superior–inferior directions, respectively. CONCLUSION: We prospectively demonstrated that the daily use of volumetric cone beam computed tomography for treatment localization in post-radical prostatectomy patients demonstrated an increased need for a shift in patient position. This suggests that in post-radical prostatectomy patients the daily cone beam computed tomography imaging improved localization of the prostate bed and may have prevented a limited number of geographic misses, compared to daily kilovoltage imaging that was not assisted with fiducials. |
format | Online Article Text |
id | pubmed-6383090 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-63830902019-02-27 Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy? Elakshar, Sara James, Man Git Tsui Michael, Jonathan Kucharczyk Tomic, Nada Fawaz, Ziad Simon Bahoric, Boris Papayanatos, Joseph Chaddad, Ahmad Niazi, Tamim Technol Cancer Res Treat Original Article PURPOSE: In this prospective phase II study, we investigated whether cone beam computed tomography scan was a superior method of image-guided radiotherapy relative to 2D orthogonal kilovoltage images in the post-radical prostatectomy setting. METHODS: A total of 419 treatment fractions were included in this analysis. The shifts required to align the patient for each treatment were performed using 3D matching between cone beam computed tomography scans and the corresponding computed tomography images used for planning. This was compared with the shifts obtained from 2D orthogonal kilovoltage images, matching with the corresponding digitally reconstructed radiographs. Patients did not have fiducials inserted to assist with localization. Interfractional changes in the bladder and rectal volumes were subsequently measured on the cone beam computed tomography images for each fraction and compared to the shift differences between orthogonal kilovoltage and cone beam computed tomography scans. The proportion of treatment fractions with a shift difference exceeding the planning target volume of 7 mm, between orthogonal kilovoltage and cone beam computed tomography scans, was calculated. RESULTS: The mean vertical, lateral, and longitudinal shifts resulted from 2D match between orthogonal kilovoltage images and corresponding digitally reconstructed radiographs were 0.353 cm (interquartile range: 0.1-0.5), 0.346 cm (interquartile range: 0.1-0.5), and 0.289 cm (interquartile range: 0.1-0.4), compared to 0.388 cm (interquartile range: 0.1-0.5), 0.342 cm (interquartile range: 0.1-0.5), and 0.291 cm (interquartile range: 0.1-0.4) obtained from 3D match between cone beam computed tomography and planning computed tomography scan, respectively. Our results show a significant difference between the kilovoltage and cone beam computed tomography shifts in the anterior–posterior direction (P = .01). The proportion of treatment fractions in which the differences in kilovoltage and cone beam computed tomography shifts between exceeded the 7 mm planning target volume margin was 6%, 2%, and 3% in the anterior–posterior, lateral, and superior–inferior directions, respectively. CONCLUSION: We prospectively demonstrated that the daily use of volumetric cone beam computed tomography for treatment localization in post-radical prostatectomy patients demonstrated an increased need for a shift in patient position. This suggests that in post-radical prostatectomy patients the daily cone beam computed tomography imaging improved localization of the prostate bed and may have prevented a limited number of geographic misses, compared to daily kilovoltage imaging that was not assisted with fiducials. SAGE Publications 2019-02-19 /pmc/articles/PMC6383090/ /pubmed/30782085 http://dx.doi.org/10.1177/1533033819831962 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Elakshar, Sara James, Man Git Tsui Michael, Jonathan Kucharczyk Tomic, Nada Fawaz, Ziad Simon Bahoric, Boris Papayanatos, Joseph Chaddad, Ahmad Niazi, Tamim Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy? |
title | Does Interfraction Cone Beam Computed Tomography Improve Target Localization
in Prostate Bed Radiotherapy? |
title_full | Does Interfraction Cone Beam Computed Tomography Improve Target Localization
in Prostate Bed Radiotherapy? |
title_fullStr | Does Interfraction Cone Beam Computed Tomography Improve Target Localization
in Prostate Bed Radiotherapy? |
title_full_unstemmed | Does Interfraction Cone Beam Computed Tomography Improve Target Localization
in Prostate Bed Radiotherapy? |
title_short | Does Interfraction Cone Beam Computed Tomography Improve Target Localization
in Prostate Bed Radiotherapy? |
title_sort | does interfraction cone beam computed tomography improve target localization
in prostate bed radiotherapy? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6383090/ https://www.ncbi.nlm.nih.gov/pubmed/30782085 http://dx.doi.org/10.1177/1533033819831962 |
work_keys_str_mv | AT elaksharsara doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT jamesmangittsui doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT michaeljonathankucharczyk doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT tomicnada doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT fawazziadsimon doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT bahoricboris doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT papayanatosjoseph doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT chaddadahmad doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy AT niazitamim doesinterfractionconebeamcomputedtomographyimprovetargetlocalizationinprostatebedradiotherapy |