Cargando…

Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy

OBJECTIVE: To evaluate the feasibility of quantifying visceral adipose tissue (VAT) on computed tomography (CT) and magnetic resonance imaging (MRI) scans, using freeware, as well as calculating intraobserver and interobserver reproducibility. MATERIALS AND METHODS: We quantified VAT in patients who...

Descripción completa

Detalles Bibliográficos
Autores principales: Pescatori, Lorenzo Carlo, Savarino, Edoardo, Mauri, Giovanni, Silvestri, Enzo, Cariati, Maurizio, Sardanelli, Francesco, Sconfienza, Luca Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6383529/
https://www.ncbi.nlm.nih.gov/pubmed/30804608
http://dx.doi.org/10.1590/0100-3984.2017.0211
_version_ 1783396855558701056
author Pescatori, Lorenzo Carlo
Savarino, Edoardo
Mauri, Giovanni
Silvestri, Enzo
Cariati, Maurizio
Sardanelli, Francesco
Sconfienza, Luca Maria
author_facet Pescatori, Lorenzo Carlo
Savarino, Edoardo
Mauri, Giovanni
Silvestri, Enzo
Cariati, Maurizio
Sardanelli, Francesco
Sconfienza, Luca Maria
author_sort Pescatori, Lorenzo Carlo
collection PubMed
description OBJECTIVE: To evaluate the feasibility of quantifying visceral adipose tissue (VAT) on computed tomography (CT) and magnetic resonance imaging (MRI) scans, using freeware, as well as calculating intraobserver and interobserver reproducibility. MATERIALS AND METHODS: We quantified VAT in patients who underwent abdominal CT and MRI at our institution between 2010 and 2015, with a maximum of three months between the two examinations. A slice acquired at the level of the umbilicus was selected. Segmentation was performed with the region growing algorithm of the freeware employed. Intraobserver and interobserver reproducibility were evaluated, as was the accuracy of MRI in relation to that of CT. RESULTS: Thirty-one patients (14 males and 17 females; mean age of 57 ± 15 years) underwent CT and MRI (mean interval between the examinations, 28 ± 12 days). The interobserver reproducibility was 82% for CT (bias = 1.52 cm(2); p = 0.488), 86% for T1-weighted MRI (bias = −4.36 cm(2); p = 0.006), and 88% for T2-weighted MRI (bias = −0.52 cm(2); p = 0.735). The intraobserver reproducibility was 90% for CT (bias = 0.14 cm(2); p = 0.912), 92% for T1-weighted MRI (bias = −3,4 cm(2); p = 0.035), and 90% for T2-weighted MRI (bias = −0.30 cm(2); p = 0.887). The reproducibility between T1-weighted MRI and T2-weighted MRI was 87% (bias = −0.11 cm(2); p = 0.957). In comparison with the accuracy of CT, that of T1-weighted and T2-weighted MRI was 89% and 91%, respectively. CONCLUSION: The program employed can be used in order to quantify VAT on CT, T1-weighted MRI, and T2-weighted MRI scans. Overall, the accuracy of MRI (in comparison with that of CT) appears to be high, as do intraobserver and interobserver reproducibility. However, the quantification of VAT seems to be less reproducible in T1-weighted sequences.
format Online
Article
Text
id pubmed-6383529
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
record_format MEDLINE/PubMed
spelling pubmed-63835292019-02-25 Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy Pescatori, Lorenzo Carlo Savarino, Edoardo Mauri, Giovanni Silvestri, Enzo Cariati, Maurizio Sardanelli, Francesco Sconfienza, Luca Maria Radiol Bras Original Articles OBJECTIVE: To evaluate the feasibility of quantifying visceral adipose tissue (VAT) on computed tomography (CT) and magnetic resonance imaging (MRI) scans, using freeware, as well as calculating intraobserver and interobserver reproducibility. MATERIALS AND METHODS: We quantified VAT in patients who underwent abdominal CT and MRI at our institution between 2010 and 2015, with a maximum of three months between the two examinations. A slice acquired at the level of the umbilicus was selected. Segmentation was performed with the region growing algorithm of the freeware employed. Intraobserver and interobserver reproducibility were evaluated, as was the accuracy of MRI in relation to that of CT. RESULTS: Thirty-one patients (14 males and 17 females; mean age of 57 ± 15 years) underwent CT and MRI (mean interval between the examinations, 28 ± 12 days). The interobserver reproducibility was 82% for CT (bias = 1.52 cm(2); p = 0.488), 86% for T1-weighted MRI (bias = −4.36 cm(2); p = 0.006), and 88% for T2-weighted MRI (bias = −0.52 cm(2); p = 0.735). The intraobserver reproducibility was 90% for CT (bias = 0.14 cm(2); p = 0.912), 92% for T1-weighted MRI (bias = −3,4 cm(2); p = 0.035), and 90% for T2-weighted MRI (bias = −0.30 cm(2); p = 0.887). The reproducibility between T1-weighted MRI and T2-weighted MRI was 87% (bias = −0.11 cm(2); p = 0.957). In comparison with the accuracy of CT, that of T1-weighted and T2-weighted MRI was 89% and 91%, respectively. CONCLUSION: The program employed can be used in order to quantify VAT on CT, T1-weighted MRI, and T2-weighted MRI scans. Overall, the accuracy of MRI (in comparison with that of CT) appears to be high, as do intraobserver and interobserver reproducibility. However, the quantification of VAT seems to be less reproducible in T1-weighted sequences. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2019 /pmc/articles/PMC6383529/ /pubmed/30804608 http://dx.doi.org/10.1590/0100-3984.2017.0211 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Pescatori, Lorenzo Carlo
Savarino, Edoardo
Mauri, Giovanni
Silvestri, Enzo
Cariati, Maurizio
Sardanelli, Francesco
Sconfienza, Luca Maria
Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title_full Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title_fullStr Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title_full_unstemmed Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title_short Quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
title_sort quantification of visceral adipose tissue by computed tomography and magnetic resonance imaging: reproducibility and accuracy
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6383529/
https://www.ncbi.nlm.nih.gov/pubmed/30804608
http://dx.doi.org/10.1590/0100-3984.2017.0211
work_keys_str_mv AT pescatorilorenzocarlo quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT savarinoedoardo quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT maurigiovanni quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT silvestrienzo quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT cariatimaurizio quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT sardanellifrancesco quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy
AT sconfienzalucamaria quantificationofvisceraladiposetissuebycomputedtomographyandmagneticresonanceimagingreproducibilityandaccuracy