Cargando…
Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results
PURPOSE: To assess the clinical usefulness of the European Thyroid Imaging and Reporting Data System (EU-TIRADS) in the valuation of thyroid nodules malignancy in reference to post-surgery histological results. MATERIAL AND METHODS: Pre-operative ultrasound was performed in consecutive patients admi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384399/ https://www.ncbi.nlm.nih.gov/pubmed/30800196 http://dx.doi.org/10.5114/pjr.2018.81556 |
_version_ | 1783396977480826880 |
---|---|
author | Skowrońska, Anna Milczarek-Banach, Justyna Wiechno, Wiesław Chudziński, Witold Żach, Marcin Mazurkiewicz, Michał Miśkiewicz, Piotr Bednarczuk, Tomasz |
author_facet | Skowrońska, Anna Milczarek-Banach, Justyna Wiechno, Wiesław Chudziński, Witold Żach, Marcin Mazurkiewicz, Michał Miśkiewicz, Piotr Bednarczuk, Tomasz |
author_sort | Skowrońska, Anna |
collection | PubMed |
description | PURPOSE: To assess the clinical usefulness of the European Thyroid Imaging and Reporting Data System (EU-TIRADS) in the valuation of thyroid nodules malignancy in reference to post-surgery histological results. MATERIAL AND METHODS: Pre-operative ultrasound was performed in consecutive patients admitted for thyroid surgery between June 2017 and January 2018. Thyroid nodules were classified according to EU-TIRADS to five groups: 1-5. At least one fine-needle aspiration biopsy (FNAB)/patient (dominant or suspected nodule) was performed in an outpatient clinic. The final diagnosis was based on the histological result. The percentage of cancers in each EU-TIRADS group was evaluated. Finally, sensitivity, specificity, accuracy, as well as positive and negative predictive values for malignancy were assessed. RESULTS: Fifty-two patients with a total of 140 thyroid nodules (median: 3 nodules/thyroid [minimum-maximum: 1-6]) were enrolled in the study. Thyroid cancer was diagnosed in 0% (0/6) in EU-TIRADS 2; 0% (0/92) in EU-TIRADS 3; 5.9% (2/34) in EU-TIRADS 4, and 75% (6/8) in EU-TIRADS 5. In nodules assessed as EU-TIRADS ≥ 4 sensitivity, specificity, positive and negative predictive values for malignancy were, respectively: 75% (CI 95%: 40.7-93.5), 94.1% (CI 95%: 86.0-98.5), 75% (CI 95%: 40.7-93.5), and 94.1% (CI 95%: 86.0-98.5). CONCLUSIONS: EU-TIRADS is a valuable and simple tool for assessment of the risk of malignancy of thyroid nodules and demonstrates a high ultrasound correlation with histological post-surgery results. FNAB should be performed in all nodules assessed as EU-TIRADS ≥ 4, due to higher risk of malignancy. |
format | Online Article Text |
id | pubmed-6384399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-63843992019-02-22 Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results Skowrońska, Anna Milczarek-Banach, Justyna Wiechno, Wiesław Chudziński, Witold Żach, Marcin Mazurkiewicz, Michał Miśkiewicz, Piotr Bednarczuk, Tomasz Pol J Radiol Original Paper PURPOSE: To assess the clinical usefulness of the European Thyroid Imaging and Reporting Data System (EU-TIRADS) in the valuation of thyroid nodules malignancy in reference to post-surgery histological results. MATERIAL AND METHODS: Pre-operative ultrasound was performed in consecutive patients admitted for thyroid surgery between June 2017 and January 2018. Thyroid nodules were classified according to EU-TIRADS to five groups: 1-5. At least one fine-needle aspiration biopsy (FNAB)/patient (dominant or suspected nodule) was performed in an outpatient clinic. The final diagnosis was based on the histological result. The percentage of cancers in each EU-TIRADS group was evaluated. Finally, sensitivity, specificity, accuracy, as well as positive and negative predictive values for malignancy were assessed. RESULTS: Fifty-two patients with a total of 140 thyroid nodules (median: 3 nodules/thyroid [minimum-maximum: 1-6]) were enrolled in the study. Thyroid cancer was diagnosed in 0% (0/6) in EU-TIRADS 2; 0% (0/92) in EU-TIRADS 3; 5.9% (2/34) in EU-TIRADS 4, and 75% (6/8) in EU-TIRADS 5. In nodules assessed as EU-TIRADS ≥ 4 sensitivity, specificity, positive and negative predictive values for malignancy were, respectively: 75% (CI 95%: 40.7-93.5), 94.1% (CI 95%: 86.0-98.5), 75% (CI 95%: 40.7-93.5), and 94.1% (CI 95%: 86.0-98.5). CONCLUSIONS: EU-TIRADS is a valuable and simple tool for assessment of the risk of malignancy of thyroid nodules and demonstrates a high ultrasound correlation with histological post-surgery results. FNAB should be performed in all nodules assessed as EU-TIRADS ≥ 4, due to higher risk of malignancy. Termedia Publishing House 2018-12-19 /pmc/articles/PMC6384399/ /pubmed/30800196 http://dx.doi.org/10.5114/pjr.2018.81556 Text en Copyright © Polish Medical Society of Radiology 2018 https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0). License allowing third parties to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially. |
spellingShingle | Original Paper Skowrońska, Anna Milczarek-Banach, Justyna Wiechno, Wiesław Chudziński, Witold Żach, Marcin Mazurkiewicz, Michał Miśkiewicz, Piotr Bednarczuk, Tomasz Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title | Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title_full | Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title_fullStr | Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title_full_unstemmed | Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title_short | Accuracy of the European Thyroid Imaging Reporting and Data System (EU-TIRADS) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
title_sort | accuracy of the european thyroid imaging reporting and data system (eu-tirads) in the valuation of thyroid nodule malignancy in reference to the post-surgery histological results |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384399/ https://www.ncbi.nlm.nih.gov/pubmed/30800196 http://dx.doi.org/10.5114/pjr.2018.81556 |
work_keys_str_mv | AT skowronskaanna accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT milczarekbanachjustyna accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT wiechnowiesław accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT chudzinskiwitold accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT zachmarcin accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT mazurkiewiczmichał accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT miskiewiczpiotr accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults AT bednarczuktomasz accuracyoftheeuropeanthyroidimagingreportinganddatasystemeutiradsinthevaluationofthyroidnodulemalignancyinreferencetothepostsurgeryhistologicalresults |