Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. S...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384555/ https://www.ncbi.nlm.nih.gov/pubmed/30695988 http://dx.doi.org/10.3390/molecules24030452 |
_version_ | 1783397005173719040 |
---|---|
author | Patyra, Ewelina Przeniosło-Siwczyńska, Monika Kwiatek, Krzysztof |
author_facet | Patyra, Ewelina Przeniosło-Siwczyńska, Monika Kwiatek, Krzysztof |
author_sort | Patyra, Ewelina |
collection | PubMed |
description | A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. Sulfonamides (SAs) were extracted from feed with an ethyl acetate/methanol/acetonitrile mixture. Clean-up was performed on a Strata-SCX cartridge. The HPLC separation was performed on a Zorbax Eclipse XDB C18 column with a gradient mobile phase system of acetic acid, methanol, and acetonitrile. The method was validated according to EU requirements (Commission Decision 2002/657/EC). Linearity, decision limit, detection capability, detection and quantification limits, recovery, precision, and selectivity were determined, and adequate results were obtained. Using the HPLC-FLD method, recoveries were satisfactory (79.3–114.0%), with repeatability and reproducibility in the range of 2.7–9.1% to 5.9–14.9%, respectively. Decision limit (CCα) and detection capability (CCβ) were 197.7–274.6 and 263.2–337.9 µg/kg, respectively, and limit of detection (LOD) and limit of quantification (LOQ) were 34.5–79.5 and 41.3–89.9 µg/kg, respectively, depending on the analyte. Results showed that this analytical procedure is simple, rapid, sensitive, and suitable for the routine control of feeds. |
format | Online Article Text |
id | pubmed-6384555 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63845552019-02-23 Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization Patyra, Ewelina Przeniosło-Siwczyńska, Monika Kwiatek, Krzysztof Molecules Article A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. Sulfonamides (SAs) were extracted from feed with an ethyl acetate/methanol/acetonitrile mixture. Clean-up was performed on a Strata-SCX cartridge. The HPLC separation was performed on a Zorbax Eclipse XDB C18 column with a gradient mobile phase system of acetic acid, methanol, and acetonitrile. The method was validated according to EU requirements (Commission Decision 2002/657/EC). Linearity, decision limit, detection capability, detection and quantification limits, recovery, precision, and selectivity were determined, and adequate results were obtained. Using the HPLC-FLD method, recoveries were satisfactory (79.3–114.0%), with repeatability and reproducibility in the range of 2.7–9.1% to 5.9–14.9%, respectively. Decision limit (CCα) and detection capability (CCβ) were 197.7–274.6 and 263.2–337.9 µg/kg, respectively, and limit of detection (LOD) and limit of quantification (LOQ) were 34.5–79.5 and 41.3–89.9 µg/kg, respectively, depending on the analyte. Results showed that this analytical procedure is simple, rapid, sensitive, and suitable for the routine control of feeds. MDPI 2019-01-28 /pmc/articles/PMC6384555/ /pubmed/30695988 http://dx.doi.org/10.3390/molecules24030452 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Patyra, Ewelina Przeniosło-Siwczyńska, Monika Kwiatek, Krzysztof Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title | Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title_full | Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title_fullStr | Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title_full_unstemmed | Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title_short | Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization |
title_sort | determination of sulfonamides in feeds by high-performance liquid chromatography after fluorescamine precolumn derivatization |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384555/ https://www.ncbi.nlm.nih.gov/pubmed/30695988 http://dx.doi.org/10.3390/molecules24030452 |
work_keys_str_mv | AT patyraewelina determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization AT przeniosłosiwczynskamonika determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization AT kwiatekkrzysztof determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization |