Cargando…

Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization

A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. S...

Descripción completa

Detalles Bibliográficos
Autores principales: Patyra, Ewelina, Przeniosło-Siwczyńska, Monika, Kwiatek, Krzysztof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384555/
https://www.ncbi.nlm.nih.gov/pubmed/30695988
http://dx.doi.org/10.3390/molecules24030452
_version_ 1783397005173719040
author Patyra, Ewelina
Przeniosło-Siwczyńska, Monika
Kwiatek, Krzysztof
author_facet Patyra, Ewelina
Przeniosło-Siwczyńska, Monika
Kwiatek, Krzysztof
author_sort Patyra, Ewelina
collection PubMed
description A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. Sulfonamides (SAs) were extracted from feed with an ethyl acetate/methanol/acetonitrile mixture. Clean-up was performed on a Strata-SCX cartridge. The HPLC separation was performed on a Zorbax Eclipse XDB C18 column with a gradient mobile phase system of acetic acid, methanol, and acetonitrile. The method was validated according to EU requirements (Commission Decision 2002/657/EC). Linearity, decision limit, detection capability, detection and quantification limits, recovery, precision, and selectivity were determined, and adequate results were obtained. Using the HPLC-FLD method, recoveries were satisfactory (79.3–114.0%), with repeatability and reproducibility in the range of 2.7–9.1% to 5.9–14.9%, respectively. Decision limit (CCα) and detection capability (CCβ) were 197.7–274.6 and 263.2–337.9 µg/kg, respectively, and limit of detection (LOD) and limit of quantification (LOQ) were 34.5–79.5 and 41.3–89.9 µg/kg, respectively, depending on the analyte. Results showed that this analytical procedure is simple, rapid, sensitive, and suitable for the routine control of feeds.
format Online
Article
Text
id pubmed-6384555
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63845552019-02-23 Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization Patyra, Ewelina Przeniosło-Siwczyńska, Monika Kwiatek, Krzysztof Molecules Article A new multi-residue method for the analysis of sulfonamides (sulfadiazine, sulfamerazine, sulfamethazine, sulfaguanidine and sulfamethoxazole) in non-target feeds using high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and precolumnderivatization was developed and validated. Sulfonamides (SAs) were extracted from feed with an ethyl acetate/methanol/acetonitrile mixture. Clean-up was performed on a Strata-SCX cartridge. The HPLC separation was performed on a Zorbax Eclipse XDB C18 column with a gradient mobile phase system of acetic acid, methanol, and acetonitrile. The method was validated according to EU requirements (Commission Decision 2002/657/EC). Linearity, decision limit, detection capability, detection and quantification limits, recovery, precision, and selectivity were determined, and adequate results were obtained. Using the HPLC-FLD method, recoveries were satisfactory (79.3–114.0%), with repeatability and reproducibility in the range of 2.7–9.1% to 5.9–14.9%, respectively. Decision limit (CCα) and detection capability (CCβ) were 197.7–274.6 and 263.2–337.9 µg/kg, respectively, and limit of detection (LOD) and limit of quantification (LOQ) were 34.5–79.5 and 41.3–89.9 µg/kg, respectively, depending on the analyte. Results showed that this analytical procedure is simple, rapid, sensitive, and suitable for the routine control of feeds. MDPI 2019-01-28 /pmc/articles/PMC6384555/ /pubmed/30695988 http://dx.doi.org/10.3390/molecules24030452 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Patyra, Ewelina
Przeniosło-Siwczyńska, Monika
Kwiatek, Krzysztof
Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title_full Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title_fullStr Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title_full_unstemmed Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title_short Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
title_sort determination of sulfonamides in feeds by high-performance liquid chromatography after fluorescamine precolumn derivatization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6384555/
https://www.ncbi.nlm.nih.gov/pubmed/30695988
http://dx.doi.org/10.3390/molecules24030452
work_keys_str_mv AT patyraewelina determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization
AT przeniosłosiwczynskamonika determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization
AT kwiatekkrzysztof determinationofsulfonamidesinfeedsbyhighperformanceliquidchromatographyafterfluorescamineprecolumnderivatization