Cargando…

Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant

The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater rece...

Descripción completa

Detalles Bibliográficos
Autores principales: Semreen, Mohammad H., Shanableh, Abdallah, Semerjian, Lucy, Alniss, Hasan, Mousa, Mouath, Bai, Xuelian, Acharya, Kumud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6385045/
https://www.ncbi.nlm.nih.gov/pubmed/30754718
http://dx.doi.org/10.3390/molecules24030633
_version_ 1783397118424121344
author Semreen, Mohammad H.
Shanableh, Abdallah
Semerjian, Lucy
Alniss, Hasan
Mousa, Mouath
Bai, Xuelian
Acharya, Kumud
author_facet Semreen, Mohammad H.
Shanableh, Abdallah
Semerjian, Lucy
Alniss, Hasan
Mousa, Mouath
Bai, Xuelian
Acharya, Kumud
author_sort Semreen, Mohammad H.
collection PubMed
description The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater received and treated by Sharjah sewage treatment plant (STP). The extraction efficiency of different SPE cartridges was tested and the simultaneous extraction of pharmaceuticals was successfully accomplished using hydrophilic-lipophilic-balanced reversed phase Waters(®) Oasis HLB cartridge (200 mg/ 6 mL) at pH 3. The analytes were separated on an Aquity BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using gradient elution and mass spectrometric analysis were performed in multiple reactions monitoring (MRM) selecting two precursor ions to produce ion transition for each pharmaceutical using positive electrospray ionization (+ESI) mode. The correlation coefficient values in the linear calibration plot for each target compound exceeded 0.99 and the recovery percentages of the investigated pharmaceuticals were more than 84%. Limit of detection (LOD) varied between 0.1–1.5 ng/L and limit of quantification (LOQ) was 0.3–5 ng/L for all analytes. The precision of the method was calculated as the relative standard deviation (RSD%) of replicate measurements and was found to be in the ranges of 2.2% to 7.7% and 2.2% to 8.6% for inter and intra-day analysis, respectively. All of the obtained validation parameters satisfied the requirements and guidelines of analytical method validation.
format Online
Article
Text
id pubmed-6385045
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63850452019-02-23 Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant Semreen, Mohammad H. Shanableh, Abdallah Semerjian, Lucy Alniss, Hasan Mousa, Mouath Bai, Xuelian Acharya, Kumud Molecules Article The present work describes the optimization and validation of a highly selective and sensitive analytical method using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE LC-MS/MS) for the determination of some frequently prescribed pharmaceuticals in urban wastewater received and treated by Sharjah sewage treatment plant (STP). The extraction efficiency of different SPE cartridges was tested and the simultaneous extraction of pharmaceuticals was successfully accomplished using hydrophilic-lipophilic-balanced reversed phase Waters(®) Oasis HLB cartridge (200 mg/ 6 mL) at pH 3. The analytes were separated on an Aquity BEH C18 column (1.7 µm, 2.1 mm × 150 mm) using gradient elution and mass spectrometric analysis were performed in multiple reactions monitoring (MRM) selecting two precursor ions to produce ion transition for each pharmaceutical using positive electrospray ionization (+ESI) mode. The correlation coefficient values in the linear calibration plot for each target compound exceeded 0.99 and the recovery percentages of the investigated pharmaceuticals were more than 84%. Limit of detection (LOD) varied between 0.1–1.5 ng/L and limit of quantification (LOQ) was 0.3–5 ng/L for all analytes. The precision of the method was calculated as the relative standard deviation (RSD%) of replicate measurements and was found to be in the ranges of 2.2% to 7.7% and 2.2% to 8.6% for inter and intra-day analysis, respectively. All of the obtained validation parameters satisfied the requirements and guidelines of analytical method validation. MDPI 2019-02-11 /pmc/articles/PMC6385045/ /pubmed/30754718 http://dx.doi.org/10.3390/molecules24030633 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Semreen, Mohammad H.
Shanableh, Abdallah
Semerjian, Lucy
Alniss, Hasan
Mousa, Mouath
Bai, Xuelian
Acharya, Kumud
Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title_full Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title_fullStr Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title_full_unstemmed Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title_short Simultaneous Determination of Pharmaceuticals by Solid-phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry: A Case Study from Sharjah Sewage Treatment Plant
title_sort simultaneous determination of pharmaceuticals by solid-phase extraction and liquid chromatography-tandem mass spectrometry: a case study from sharjah sewage treatment plant
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6385045/
https://www.ncbi.nlm.nih.gov/pubmed/30754718
http://dx.doi.org/10.3390/molecules24030633
work_keys_str_mv AT semreenmohammadh simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT shanablehabdallah simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT semerjianlucy simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT alnisshasan simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT mousamouath simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT baixuelian simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant
AT acharyakumud simultaneousdeterminationofpharmaceuticalsbysolidphaseextractionandliquidchromatographytandemmassspectrometryacasestudyfromsharjahsewagetreatmentplant