Blood Flow after Endovascular Repair in the Aortic Arch: A Computational Analysis

Background  The benefits of thoracic endovascular aortic repair (TEVAR) have encouraged stent graft deployment more proximally in the aortic arch. This study quantifies the hemodynamic impact of TEVAR in proximal landing zone 2 on the thoracic aorta and the proximal supra-aortic branches. Methods  P...

Descripción completa

Detalles Bibliográficos
Autores principales: van Bakel, Theodorus M., Romarowski, Rodrigo M., Morganti, Simone, van Herwaarden, Joost A., Moll, Frans L., de Beaufort, Hector W., Marrocco-Trischitta, Massimiliano M., Secchi, Francesco, Conti, Michele, Auricchio, Ferdinando, Trimarchi, Santi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6386644/
https://www.ncbi.nlm.nih.gov/pubmed/30795032
http://dx.doi.org/10.1055/s-0039-1683771
Descripción
Sumario:Background  The benefits of thoracic endovascular aortic repair (TEVAR) have encouraged stent graft deployment more proximally in the aortic arch. This study quantifies the hemodynamic impact of TEVAR in proximal landing zone 2 on the thoracic aorta and the proximal supra-aortic branches. Methods  Patients treated with TEVAR in proximal landing zone 2 having available preoperative and 30-day postoperative computer tomography angiography and phase-contrast magnetic resonance imaging data were retrospectively selected. Blood flow was studied using patient-specific computational fluid dynamics simulations. Results  Four patients were included. Following TEVAR in proximal landing zone 2, the mean flow in the left common carotid artery (LCCA) increased almost threefold, from 0.21 (0.12–0.41) L/min to 0.61 (0.24–1.08) L/min (+294%). The surface area of the LCCA had not yet increased commensurately and therefore maximum flow velocity in the LCCA increased from 44.9 (27.0–89.3) cm/s to 72.6 (40.8–135.0) cm/s (+62%). One of the patients presented with Type Ib endoleak at 1-year follow-up. The displacement force in this patient measured 32.1 N and was directed dorsocranial, perpendicular to the distal sealing zone. There was a linear correlation between the surface area of the stent graft and the resulting displacement force ( p  = 0.04). Conclusion  TEVAR in proximal landing zone 2 alters blood flow in the supra-aortic branches, resulting in increased flow with high flow velocities in the LCCA. High displacement forces were calculated and related to stent graft migration and Type I endoleak during 1-year follow-up.