Cargando…

Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns

Defects between fiber reinforced polymer (FRP) and repaired concrete components may easily come out due to misoperation during manufacturing, environmental deterioration, or impact from external load during service life. The defects may cause a degraded structure performance and even the unexpected...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Renyuan, Lau, Denvid, Tam, Lik-ho, Liu, Tiejun, Zou, Dujian, Zhou, Ao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6386907/
https://www.ncbi.nlm.nih.gov/pubmed/30678346
http://dx.doi.org/10.3390/s19030468
_version_ 1783397450493460480
author Qin, Renyuan
Lau, Denvid
Tam, Lik-ho
Liu, Tiejun
Zou, Dujian
Zhou, Ao
author_facet Qin, Renyuan
Lau, Denvid
Tam, Lik-ho
Liu, Tiejun
Zou, Dujian
Zhou, Ao
author_sort Qin, Renyuan
collection PubMed
description Defects between fiber reinforced polymer (FRP) and repaired concrete components may easily come out due to misoperation during manufacturing, environmental deterioration, or impact from external load during service life. The defects may cause a degraded structure performance and even the unexpected structural failure. Different non-destructive techniques (NDTs) and sensors have been developed to assess the defects in FRP bonded system. The information of linking up the detected defects by NDTs and repair schemes is needed by assessing the criticality of detected defects. In this study, FRP confined concrete columns with interfacial defects were experimentally tested to determine the interfacial defect criticality on structural performance. It is found that interfacial defect can reduce the FRP confinement effectiveness, and ultimate strength and its corresponding strain of column deteriorate significantly if the interfacial defect area is larger than 50% of total confinement area. Meanwhile, proposed analytical model considering the defect ratio is validated for the prediction of stress–strain behavior of FRP confined columns. The evaluation of defect criticality could be made by comparing predicted stress–strain behavior with the original design to determine corresponding maintenance strategies.
format Online
Article
Text
id pubmed-6386907
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63869072019-02-26 Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns Qin, Renyuan Lau, Denvid Tam, Lik-ho Liu, Tiejun Zou, Dujian Zhou, Ao Sensors (Basel) Article Defects between fiber reinforced polymer (FRP) and repaired concrete components may easily come out due to misoperation during manufacturing, environmental deterioration, or impact from external load during service life. The defects may cause a degraded structure performance and even the unexpected structural failure. Different non-destructive techniques (NDTs) and sensors have been developed to assess the defects in FRP bonded system. The information of linking up the detected defects by NDTs and repair schemes is needed by assessing the criticality of detected defects. In this study, FRP confined concrete columns with interfacial defects were experimentally tested to determine the interfacial defect criticality on structural performance. It is found that interfacial defect can reduce the FRP confinement effectiveness, and ultimate strength and its corresponding strain of column deteriorate significantly if the interfacial defect area is larger than 50% of total confinement area. Meanwhile, proposed analytical model considering the defect ratio is validated for the prediction of stress–strain behavior of FRP confined columns. The evaluation of defect criticality could be made by comparing predicted stress–strain behavior with the original design to determine corresponding maintenance strategies. MDPI 2019-01-24 /pmc/articles/PMC6386907/ /pubmed/30678346 http://dx.doi.org/10.3390/s19030468 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qin, Renyuan
Lau, Denvid
Tam, Lik-ho
Liu, Tiejun
Zou, Dujian
Zhou, Ao
Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title_full Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title_fullStr Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title_full_unstemmed Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title_short Experimental Investigation on Interfacial Defect Criticality of FRP-Confined Concrete Columns
title_sort experimental investigation on interfacial defect criticality of frp-confined concrete columns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6386907/
https://www.ncbi.nlm.nih.gov/pubmed/30678346
http://dx.doi.org/10.3390/s19030468
work_keys_str_mv AT qinrenyuan experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns
AT laudenvid experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns
AT tamlikho experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns
AT liutiejun experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns
AT zoudujian experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns
AT zhouao experimentalinvestigationoninterfacialdefectcriticalityoffrpconfinedconcretecolumns