Cargando…

Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode

Tumor necrosis factor-α (TNF-α) is a biomarker of inflammation that occurs in patients suffering from heart failure (HF). Saliva can be sampled in a non-invasive way, and it is currently gaining importance as matrix alternative to blood in diagnostic and therapy monitoring. This work presents the de...

Descripción completa

Detalles Bibliográficos
Autores principales: Barhoumi, Lassaad, Bellagambi, Francesca G., Vivaldi, Federico M., Baraket, Abdoullatif, Clément, Yohann, Zine, Nadia, Ben Ali, Mounir, Elaissari, Abdelhamid, Errachid, Abdelhamid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6387098/
https://www.ncbi.nlm.nih.gov/pubmed/30744018
http://dx.doi.org/10.3390/s19030692
_version_ 1783397495181672448
author Barhoumi, Lassaad
Bellagambi, Francesca G.
Vivaldi, Federico M.
Baraket, Abdoullatif
Clément, Yohann
Zine, Nadia
Ben Ali, Mounir
Elaissari, Abdelhamid
Errachid, Abdelhamid
author_facet Barhoumi, Lassaad
Bellagambi, Francesca G.
Vivaldi, Federico M.
Baraket, Abdoullatif
Clément, Yohann
Zine, Nadia
Ben Ali, Mounir
Elaissari, Abdelhamid
Errachid, Abdelhamid
author_sort Barhoumi, Lassaad
collection PubMed
description Tumor necrosis factor-α (TNF-α) is a biomarker of inflammation that occurs in patients suffering from heart failure (HF). Saliva can be sampled in a non-invasive way, and it is currently gaining importance as matrix alternative to blood in diagnostic and therapy monitoring. This work presents the development of an immunosensor array based on eight screen-printed gold electrodes to detect TNF-α in saliva samples. Two different functionalization strategies of electrodes were compared. In the first, anti-TNF-α antibodies were chemically bonded onto the electrode by functionalization with 4-carboxymethylaniline. The other functionalization procedure involved the binding of antibodies onto polymer-coated magnetic microparticles, which were then deposited onto the electrode by pulsed chronoamperometry. Finally, the chronoamperometry technique was applied to characterize the modified SPEAu. The use of a secondary antibody anti-TNF-α (Ab-TNF-α-HRP) labelled with horseradish peroxidase (HRP, 2 µg·mL(−1)) was investigated using tetramethylbenzidine (TMB, pH = 3.75) as electrochemical substrate containing 0.2 mM of H(2)O(2). A sandwich-type detection strategy with a secondary antibody anti-TNF-α provided chronoamperometric analyses in 10 s for each sample. Linearity, precision, limit of detection, and selectivity of devices were investigated. Interferences were evaluated by analyzing solutions containing other cytokine produced during the acute stage of inflammation. The immunosensor showed good performance within the clinically relevant concentration range, with a precision of 8%, and a limit of detection of 0.3 pg/mL. Therefore, it may represent a promising tool for monitoring HF in a non-invasive way.
format Online
Article
Text
id pubmed-6387098
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63870982019-02-26 Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode Barhoumi, Lassaad Bellagambi, Francesca G. Vivaldi, Federico M. Baraket, Abdoullatif Clément, Yohann Zine, Nadia Ben Ali, Mounir Elaissari, Abdelhamid Errachid, Abdelhamid Sensors (Basel) Article Tumor necrosis factor-α (TNF-α) is a biomarker of inflammation that occurs in patients suffering from heart failure (HF). Saliva can be sampled in a non-invasive way, and it is currently gaining importance as matrix alternative to blood in diagnostic and therapy monitoring. This work presents the development of an immunosensor array based on eight screen-printed gold electrodes to detect TNF-α in saliva samples. Two different functionalization strategies of electrodes were compared. In the first, anti-TNF-α antibodies were chemically bonded onto the electrode by functionalization with 4-carboxymethylaniline. The other functionalization procedure involved the binding of antibodies onto polymer-coated magnetic microparticles, which were then deposited onto the electrode by pulsed chronoamperometry. Finally, the chronoamperometry technique was applied to characterize the modified SPEAu. The use of a secondary antibody anti-TNF-α (Ab-TNF-α-HRP) labelled with horseradish peroxidase (HRP, 2 µg·mL(−1)) was investigated using tetramethylbenzidine (TMB, pH = 3.75) as electrochemical substrate containing 0.2 mM of H(2)O(2). A sandwich-type detection strategy with a secondary antibody anti-TNF-α provided chronoamperometric analyses in 10 s for each sample. Linearity, precision, limit of detection, and selectivity of devices were investigated. Interferences were evaluated by analyzing solutions containing other cytokine produced during the acute stage of inflammation. The immunosensor showed good performance within the clinically relevant concentration range, with a precision of 8%, and a limit of detection of 0.3 pg/mL. Therefore, it may represent a promising tool for monitoring HF in a non-invasive way. MDPI 2019-02-08 /pmc/articles/PMC6387098/ /pubmed/30744018 http://dx.doi.org/10.3390/s19030692 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Barhoumi, Lassaad
Bellagambi, Francesca G.
Vivaldi, Federico M.
Baraket, Abdoullatif
Clément, Yohann
Zine, Nadia
Ben Ali, Mounir
Elaissari, Abdelhamid
Errachid, Abdelhamid
Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title_full Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title_fullStr Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title_full_unstemmed Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title_short Ultrasensitive Immunosensor Array for TNF-α Detection in Artificial Saliva using Polymer-Coated Magnetic Microparticles onto Screen-Printed Gold Electrode
title_sort ultrasensitive immunosensor array for tnf-α detection in artificial saliva using polymer-coated magnetic microparticles onto screen-printed gold electrode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6387098/
https://www.ncbi.nlm.nih.gov/pubmed/30744018
http://dx.doi.org/10.3390/s19030692
work_keys_str_mv AT barhoumilassaad ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT bellagambifrancescag ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT vivaldifedericom ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT baraketabdoullatif ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT clementyohann ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT zinenadia ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT benalimounir ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT elaissariabdelhamid ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode
AT errachidabdelhamid ultrasensitiveimmunosensorarrayfortnfadetectioninartificialsalivausingpolymercoatedmagneticmicroparticlesontoscreenprintedgoldelectrode