Cargando…
Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor
Rapid detection of spraying deposit can contribute to the precision application of plant protection products. In this study, a novel capacitor sensor system was implemented for measuring the spray deposit immediately after herbicide application. Herbicides with different formulations and nozzles in...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6387286/ https://www.ncbi.nlm.nih.gov/pubmed/30696019 http://dx.doi.org/10.3390/s19030537 |
_version_ | 1783397546729668608 |
---|---|
author | Wang, Pei Yu, Wei Ou, Mingxiong Gong, Chen Jia, Weidong |
author_facet | Wang, Pei Yu, Wei Ou, Mingxiong Gong, Chen Jia, Weidong |
author_sort | Wang, Pei |
collection | PubMed |
description | Rapid detection of spraying deposit can contribute to the precision application of plant protection products. In this study, a novel capacitor sensor system was implemented for measuring the spray deposit immediately after herbicide application. Herbicides with different formulations and nozzles in different mode types were included to test the impact on the capacitance of this system. The results showed that there was a linear relationship between the deposit mass and the digital voltage signals of the capacitance on the sensor surface with spray droplets. The linear models were similar for water and the spray mixtures with non-ionized herbicides usually in formulations of emulsifiable concentrates and suspension concentrates. However, the ionized herbicides in formulation of aqueous solutions presented a unique linear model. With this novel sensor, it is possible to monitor the deposit mass in real-time shortly after the pesticide application. This will contribute to the precision application of plant protection chemicals in the fields. |
format | Online Article Text |
id | pubmed-6387286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-63872862019-02-26 Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor Wang, Pei Yu, Wei Ou, Mingxiong Gong, Chen Jia, Weidong Sensors (Basel) Article Rapid detection of spraying deposit can contribute to the precision application of plant protection products. In this study, a novel capacitor sensor system was implemented for measuring the spray deposit immediately after herbicide application. Herbicides with different formulations and nozzles in different mode types were included to test the impact on the capacitance of this system. The results showed that there was a linear relationship between the deposit mass and the digital voltage signals of the capacitance on the sensor surface with spray droplets. The linear models were similar for water and the spray mixtures with non-ionized herbicides usually in formulations of emulsifiable concentrates and suspension concentrates. However, the ionized herbicides in formulation of aqueous solutions presented a unique linear model. With this novel sensor, it is possible to monitor the deposit mass in real-time shortly after the pesticide application. This will contribute to the precision application of plant protection chemicals in the fields. MDPI 2019-01-28 /pmc/articles/PMC6387286/ /pubmed/30696019 http://dx.doi.org/10.3390/s19030537 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Pei Yu, Wei Ou, Mingxiong Gong, Chen Jia, Weidong Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title | Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title_full | Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title_fullStr | Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title_full_unstemmed | Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title_short | Monitoring of the Pesticide Droplet Deposition with a Novel Capacitance Sensor |
title_sort | monitoring of the pesticide droplet deposition with a novel capacitance sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6387286/ https://www.ncbi.nlm.nih.gov/pubmed/30696019 http://dx.doi.org/10.3390/s19030537 |
work_keys_str_mv | AT wangpei monitoringofthepesticidedropletdepositionwithanovelcapacitancesensor AT yuwei monitoringofthepesticidedropletdepositionwithanovelcapacitancesensor AT oumingxiong monitoringofthepesticidedropletdepositionwithanovelcapacitancesensor AT gongchen monitoringofthepesticidedropletdepositionwithanovelcapacitancesensor AT jiaweidong monitoringofthepesticidedropletdepositionwithanovelcapacitancesensor |