Cargando…

Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge

The use of hearing protectors in various noisy workplaces is often necessary. For safety reasons, auditory information may be required to correctly localize the direction of an auditory danger signal. The purpose of this study was to verify if the selection of a specific level-dependent hearing prot...

Descripción completa

Detalles Bibliográficos
Autores principales: Mlynski, Rafal, Kozlowski, Emil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388283/
https://www.ncbi.nlm.nih.gov/pubmed/30704136
http://dx.doi.org/10.3390/ijerph16030394
_version_ 1783397735505854464
author Mlynski, Rafal
Kozlowski, Emil
author_facet Mlynski, Rafal
Kozlowski, Emil
author_sort Mlynski, Rafal
collection PubMed
description The use of hearing protectors in various noisy workplaces is often necessary. For safety reasons, auditory information may be required to correctly localize the direction of an auditory danger signal. The purpose of this study was to verify if the selection of a specific level-dependent hearing protector may be important for the ability to localize a vehicle back-up alarm signal. The laboratory conditions reflected industrial conditions, under which an impulse noise was emitted against a background of continuous noise. A passive mode and a level-dependent mode (maximum and incomplete amplification) were considered. Four different models of level-dependent earmuffs and one model of level-dependent earplugs were included in the tests. The tests enabled differentiation between the individual hearing protectors. The use of earplugs in level-dependent mode did not significantly affect the ability to correctly localize the back-up alarm signal. For the earmuffs, the global assessment of the impact of a mode change revealed that, depending on the model of the earmuffs, the impact may be insignificant, but may also result in considerable impairment of the ability to localize the back-up alarm signal.
format Online
Article
Text
id pubmed-6388283
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-63882832019-02-27 Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge Mlynski, Rafal Kozlowski, Emil Int J Environ Res Public Health Article The use of hearing protectors in various noisy workplaces is often necessary. For safety reasons, auditory information may be required to correctly localize the direction of an auditory danger signal. The purpose of this study was to verify if the selection of a specific level-dependent hearing protector may be important for the ability to localize a vehicle back-up alarm signal. The laboratory conditions reflected industrial conditions, under which an impulse noise was emitted against a background of continuous noise. A passive mode and a level-dependent mode (maximum and incomplete amplification) were considered. Four different models of level-dependent earmuffs and one model of level-dependent earplugs were included in the tests. The tests enabled differentiation between the individual hearing protectors. The use of earplugs in level-dependent mode did not significantly affect the ability to correctly localize the back-up alarm signal. For the earmuffs, the global assessment of the impact of a mode change revealed that, depending on the model of the earmuffs, the impact may be insignificant, but may also result in considerable impairment of the ability to localize the back-up alarm signal. MDPI 2019-01-30 2019-02 /pmc/articles/PMC6388283/ /pubmed/30704136 http://dx.doi.org/10.3390/ijerph16030394 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mlynski, Rafal
Kozlowski, Emil
Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title_full Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title_fullStr Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title_full_unstemmed Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title_short Localization of Vehicle Back-Up Alarms by Users of Level-Dependent Hearing Protectors under Industrial Noise Conditions Generated at a Forge
title_sort localization of vehicle back-up alarms by users of level-dependent hearing protectors under industrial noise conditions generated at a forge
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388283/
https://www.ncbi.nlm.nih.gov/pubmed/30704136
http://dx.doi.org/10.3390/ijerph16030394
work_keys_str_mv AT mlynskirafal localizationofvehiclebackupalarmsbyusersofleveldependenthearingprotectorsunderindustrialnoiseconditionsgeneratedataforge
AT kozlowskiemil localizationofvehiclebackupalarmsbyusersofleveldependenthearingprotectorsunderindustrialnoiseconditionsgeneratedataforge