Cargando…

Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty

PURPOSE: To evaluate the effects of donor graft thickness on postoperative best spectacle-corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet stripping automated endothelial kera...

Descripción completa

Detalles Bibliográficos
Autores principales: Feizi, Sepehr, Javadi, Mohammad Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388529/
https://www.ncbi.nlm.nih.gov/pubmed/30820282
http://dx.doi.org/10.4103/jovr.jovr_55_17
_version_ 1783397782498836480
author Feizi, Sepehr
Javadi, Mohammad Ali
author_facet Feizi, Sepehr
Javadi, Mohammad Ali
author_sort Feizi, Sepehr
collection PubMed
description PURPOSE: To evaluate the effects of donor graft thickness on postoperative best spectacle-corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS: This retrospective, interventional case series enrolled 77 eyes of 64 patients who underwent DSAEK with or without simultaneous cataract surgery. Clinical outcomes, including BSCVA, refraction, keratometric astigmatism, IOP, and ECD were assessed at the final follow-up examination. Univariate analyses were used to investigate the effects of postoperative donor graft thickness on clinical outcomes and complications. RESULTS: The mean patient age was 62.3 ± 15.6 years, and the patients were followed for 26.2 ± 20.9 months postoperatively. The mean postoperative central graft thickness was 102.4 ± 31.6 μm. In the univariate analysis, postoperative central graft thickness was significantly associated with postoperative IOP (P = 0.005), central recipient thickness (P = 0.002), and ECD (P = 0.016). No significant association was found for central graft thickness with postoperative BSCVA (P = 0.70), spherical equivalent refraction (P = 0.33), keratometric astigmatism (P = 0.27), graft detachment (P = 0.16), graft decentration (P = 0.17), high IOP (P = 0.53), or endothelial rejection (P = 0.88). CONCLUSION: This study failed to demonstrate any significant correlation between graft thickness and BSCVA. Attempting to minimize graft thickness might not have the desired outcome regarding endothelial cell density and function. Increased graft thickness could negatively impact the accuracy of IOP measurements after DSAEK.
format Online
Article
Text
id pubmed-6388529
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-63885292019-02-28 Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty Feizi, Sepehr Javadi, Mohammad Ali J Ophthalmic Vis Res Original Article PURPOSE: To evaluate the effects of donor graft thickness on postoperative best spectacle-corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet stripping automated endothelial keratoplasty (DSAEK). METHODS: This retrospective, interventional case series enrolled 77 eyes of 64 patients who underwent DSAEK with or without simultaneous cataract surgery. Clinical outcomes, including BSCVA, refraction, keratometric astigmatism, IOP, and ECD were assessed at the final follow-up examination. Univariate analyses were used to investigate the effects of postoperative donor graft thickness on clinical outcomes and complications. RESULTS: The mean patient age was 62.3 ± 15.6 years, and the patients were followed for 26.2 ± 20.9 months postoperatively. The mean postoperative central graft thickness was 102.4 ± 31.6 μm. In the univariate analysis, postoperative central graft thickness was significantly associated with postoperative IOP (P = 0.005), central recipient thickness (P = 0.002), and ECD (P = 0.016). No significant association was found for central graft thickness with postoperative BSCVA (P = 0.70), spherical equivalent refraction (P = 0.33), keratometric astigmatism (P = 0.27), graft detachment (P = 0.16), graft decentration (P = 0.17), high IOP (P = 0.53), or endothelial rejection (P = 0.88). CONCLUSION: This study failed to demonstrate any significant correlation between graft thickness and BSCVA. Attempting to minimize graft thickness might not have the desired outcome regarding endothelial cell density and function. Increased graft thickness could negatively impact the accuracy of IOP measurements after DSAEK. Medknow Publications & Media Pvt Ltd 2019 /pmc/articles/PMC6388529/ /pubmed/30820282 http://dx.doi.org/10.4103/jovr.jovr_55_17 Text en Copyright: © 2019 Journal of Ophthalmic and Vision Research http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Feizi, Sepehr
Javadi, Mohammad Ali
Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title_full Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title_fullStr Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title_full_unstemmed Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title_short Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
title_sort effect of donor graft thickness on clinical outcomes after descemet stripping automated endothelial keratoplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388529/
https://www.ncbi.nlm.nih.gov/pubmed/30820282
http://dx.doi.org/10.4103/jovr.jovr_55_17
work_keys_str_mv AT feizisepehr effectofdonorgraftthicknessonclinicaloutcomesafterdescemetstrippingautomatedendothelialkeratoplasty
AT javadimohammadali effectofdonorgraftthicknessonclinicaloutcomesafterdescemetstrippingautomatedendothelialkeratoplasty