Cargando…

Microbiological contamination of ear, nose and throat (ENT) units

Aim: In ENT (Ear, Nose and Throat) treatment units, medical devices for examination are commonly stored on open trays. The aim of this study is to investigate whether open storage is a relevant cause for microbiological contamination of ENT instruments during a working day. Methods: Qualitative and...

Descripción completa

Detalles Bibliográficos
Autores principales: Krull, Marco, Steinmann, Joerg, Heintschel von Heinegg, Evelyn, Buer, Jan, Sucharski, Anke, Mattheis, Stefan, Lang, Stephan, Ross, Birgit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: German Medical Science GMS Publishing House 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388672/
https://www.ncbi.nlm.nih.gov/pubmed/30834191
http://dx.doi.org/10.3205/dgkh000319
_version_ 1783397801823043584
author Krull, Marco
Steinmann, Joerg
Heintschel von Heinegg, Evelyn
Buer, Jan
Sucharski, Anke
Mattheis, Stefan
Lang, Stephan
Ross, Birgit
author_facet Krull, Marco
Steinmann, Joerg
Heintschel von Heinegg, Evelyn
Buer, Jan
Sucharski, Anke
Mattheis, Stefan
Lang, Stephan
Ross, Birgit
author_sort Krull, Marco
collection PubMed
description Aim: In ENT (Ear, Nose and Throat) treatment units, medical devices for examination are commonly stored on open trays. The aim of this study is to investigate whether open storage is a relevant cause for microbiological contamination of ENT instruments during a working day. Methods: Qualitative and quantitative tests, such as imprints and swabs, were performed on the instruments and the surfaces of the treatment units in an ENT outpatient clinic at the beginning and at the end of consultation hours. The microbiological analysis of the samples focused on potential pathogens, e.g., Staphylococcus aureus or Pseudomonas aeruginosa, bacteria of skin and oral microbiota, as well as the number of colony forming units (CFU). The samples were collected at three distinct ENT treatment units over five working days. Results: The samples taken at the beginning of consultation hours showed a low number of CFU and no pathogens. Overall, 5% of the instruments were contaminated with bacteria of skin microbiota. At the end of a working day, this rate increased significantly to 17.5% (p<0.01). At the beginning of the working day, the mean number on the instrument trays was 4 CFU/25 cm², which increased to 34 CFU/25 cm² at the end of the working day. In some cases of the imprints taken at the end of the working day showed that a bacterial lawn had formed. In two cases, the pathogens Ralstonia picketii and Enterobacter cloacae were detected; in another case Bacillus spp. was identified. The contamination of ENT instruments and the ENT treatment unit increased significantly (p<0.01) over the duration of consultation hours. Conclusion: The results show that the current hygiene requirements for storage und reprocessing are not sufficient to conform to the mandatory guidelines of the German Commission on Hospital Hygiene and Infection Prevention. Although we could not find a pressing risk for the patients, we also cannot exclude it in the long term. Thus, new concepts are needed.
format Online
Article
Text
id pubmed-6388672
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher German Medical Science GMS Publishing House
record_format MEDLINE/PubMed
spelling pubmed-63886722019-03-04 Microbiological contamination of ear, nose and throat (ENT) units Krull, Marco Steinmann, Joerg Heintschel von Heinegg, Evelyn Buer, Jan Sucharski, Anke Mattheis, Stefan Lang, Stephan Ross, Birgit GMS Hyg Infect Control Article Aim: In ENT (Ear, Nose and Throat) treatment units, medical devices for examination are commonly stored on open trays. The aim of this study is to investigate whether open storage is a relevant cause for microbiological contamination of ENT instruments during a working day. Methods: Qualitative and quantitative tests, such as imprints and swabs, were performed on the instruments and the surfaces of the treatment units in an ENT outpatient clinic at the beginning and at the end of consultation hours. The microbiological analysis of the samples focused on potential pathogens, e.g., Staphylococcus aureus or Pseudomonas aeruginosa, bacteria of skin and oral microbiota, as well as the number of colony forming units (CFU). The samples were collected at three distinct ENT treatment units over five working days. Results: The samples taken at the beginning of consultation hours showed a low number of CFU and no pathogens. Overall, 5% of the instruments were contaminated with bacteria of skin microbiota. At the end of a working day, this rate increased significantly to 17.5% (p<0.01). At the beginning of the working day, the mean number on the instrument trays was 4 CFU/25 cm², which increased to 34 CFU/25 cm² at the end of the working day. In some cases of the imprints taken at the end of the working day showed that a bacterial lawn had formed. In two cases, the pathogens Ralstonia picketii and Enterobacter cloacae were detected; in another case Bacillus spp. was identified. The contamination of ENT instruments and the ENT treatment unit increased significantly (p<0.01) over the duration of consultation hours. Conclusion: The results show that the current hygiene requirements for storage und reprocessing are not sufficient to conform to the mandatory guidelines of the German Commission on Hospital Hygiene and Infection Prevention. Although we could not find a pressing risk for the patients, we also cannot exclude it in the long term. Thus, new concepts are needed. German Medical Science GMS Publishing House 2019-02-01 /pmc/articles/PMC6388672/ /pubmed/30834191 http://dx.doi.org/10.3205/dgkh000319 Text en Copyright © 2019 Krull et al. This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License. See license information at http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Krull, Marco
Steinmann, Joerg
Heintschel von Heinegg, Evelyn
Buer, Jan
Sucharski, Anke
Mattheis, Stefan
Lang, Stephan
Ross, Birgit
Microbiological contamination of ear, nose and throat (ENT) units
title Microbiological contamination of ear, nose and throat (ENT) units
title_full Microbiological contamination of ear, nose and throat (ENT) units
title_fullStr Microbiological contamination of ear, nose and throat (ENT) units
title_full_unstemmed Microbiological contamination of ear, nose and throat (ENT) units
title_short Microbiological contamination of ear, nose and throat (ENT) units
title_sort microbiological contamination of ear, nose and throat (ent) units
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6388672/
https://www.ncbi.nlm.nih.gov/pubmed/30834191
http://dx.doi.org/10.3205/dgkh000319
work_keys_str_mv AT krullmarco microbiologicalcontaminationofearnoseandthroatentunits
AT steinmannjoerg microbiologicalcontaminationofearnoseandthroatentunits
AT heintschelvonheineggevelyn microbiologicalcontaminationofearnoseandthroatentunits
AT buerjan microbiologicalcontaminationofearnoseandthroatentunits
AT sucharskianke microbiologicalcontaminationofearnoseandthroatentunits
AT mattheisstefan microbiologicalcontaminationofearnoseandthroatentunits
AT langstephan microbiologicalcontaminationofearnoseandthroatentunits
AT rossbirgit microbiologicalcontaminationofearnoseandthroatentunits