Cargando…
Case report of a type III endoleak presenting only decades after endovascular aortic repair
Introduction: Type III endoleaks are a rare but potentially life-threatening complication post endovascular aortic aneurysm repair (EVAR). Case report: A 91-year-old Chinese female, presented to our accident and emergency department for severe back and abdominal pain. She had previously undergone an...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6389550/ https://www.ncbi.nlm.nih.gov/pubmed/30798094 http://dx.doi.org/10.1016/j.ijscr.2019.01.008 |
_version_ | 1783397959134609408 |
---|---|
author | Lee, T.S.Q. Chong, T.T. Wang, J.C.C. Choke, T.C.E. Tang, T.Y. |
author_facet | Lee, T.S.Q. Chong, T.T. Wang, J.C.C. Choke, T.C.E. Tang, T.Y. |
author_sort | Lee, T.S.Q. |
collection | PubMed |
description | Introduction: Type III endoleaks are a rare but potentially life-threatening complication post endovascular aortic aneurysm repair (EVAR). Case report: A 91-year-old Chinese female, presented to our accident and emergency department for severe back and abdominal pain. She had previously undergone an EVAR procedure twenty years ago for a 6.5 cm diameter infra-renal abdominal aortic aneurysm. A CT aortogram revealed a type III endoleak, with the contralateral limb found to be disconnected from the main graft body. She was successfully treated by relining the graft using an endovascular technique. Discussion: The case highlights the need for life-long stent-graft surveillance. We discuss early generation stent-grafts, type III endoleak treatment options and the current long-term data for late EVAR-related complications. Conclusion: For patients who had undergone EVAR, type III endoleaks can present only decades later and pose a significant risk of aneurysmal rupture. |
format | Online Article Text |
id | pubmed-6389550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-63895502019-03-07 Case report of a type III endoleak presenting only decades after endovascular aortic repair Lee, T.S.Q. Chong, T.T. Wang, J.C.C. Choke, T.C.E. Tang, T.Y. Int J Surg Case Rep Article Introduction: Type III endoleaks are a rare but potentially life-threatening complication post endovascular aortic aneurysm repair (EVAR). Case report: A 91-year-old Chinese female, presented to our accident and emergency department for severe back and abdominal pain. She had previously undergone an EVAR procedure twenty years ago for a 6.5 cm diameter infra-renal abdominal aortic aneurysm. A CT aortogram revealed a type III endoleak, with the contralateral limb found to be disconnected from the main graft body. She was successfully treated by relining the graft using an endovascular technique. Discussion: The case highlights the need for life-long stent-graft surveillance. We discuss early generation stent-grafts, type III endoleak treatment options and the current long-term data for late EVAR-related complications. Conclusion: For patients who had undergone EVAR, type III endoleaks can present only decades later and pose a significant risk of aneurysmal rupture. Elsevier 2019-01-18 /pmc/articles/PMC6389550/ /pubmed/30798094 http://dx.doi.org/10.1016/j.ijscr.2019.01.008 Text en © 2019 Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lee, T.S.Q. Chong, T.T. Wang, J.C.C. Choke, T.C.E. Tang, T.Y. Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title | Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title_full | Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title_fullStr | Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title_full_unstemmed | Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title_short | Case report of a type III endoleak presenting only decades after endovascular aortic repair |
title_sort | case report of a type iii endoleak presenting only decades after endovascular aortic repair |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6389550/ https://www.ncbi.nlm.nih.gov/pubmed/30798094 http://dx.doi.org/10.1016/j.ijscr.2019.01.008 |
work_keys_str_mv | AT leetsq casereportofatypeiiiendoleakpresentingonlydecadesafterendovascularaorticrepair AT chongtt casereportofatypeiiiendoleakpresentingonlydecadesafterendovascularaorticrepair AT wangjcc casereportofatypeiiiendoleakpresentingonlydecadesafterendovascularaorticrepair AT choketce casereportofatypeiiiendoleakpresentingonlydecadesafterendovascularaorticrepair AT tangty casereportofatypeiiiendoleakpresentingonlydecadesafterendovascularaorticrepair |