Cargando…
Validation of clinic-based cryptococcal antigen lateral flow assay screening in HIV-infected adults in South Africa
Since rapid cryptococcal antigen lateral flow assays (CrAg LFA) may expedite treatment of HIV-associated cryptococcal infections, we sought to validate clinic-based CrAg LFA testing. Among newly-diagnosed HIV-infected adults in South Africa, a trained nurse performed clinic-based testing of urine, f...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6389876/ https://www.ncbi.nlm.nih.gov/pubmed/30804356 http://dx.doi.org/10.1038/s41598-018-37478-7 |
Sumario: | Since rapid cryptococcal antigen lateral flow assays (CrAg LFA) may expedite treatment of HIV-associated cryptococcal infections, we sought to validate clinic-based CrAg LFA testing. Among newly-diagnosed HIV-infected adults in South Africa, a trained nurse performed clinic-based testing of urine, fingerprick capillary and venous whole blood with rapid CrAg LFA (Immy Diagnostics, Norman, USA). We performed matched laboratory-based serum cryptococcal antigen testing with an enzyme immunoassay (EIA). We assessed diagnostic accuracy using EIA as the gold-standard, and performed additional validation testing on serum and among hospitalized adults with cryptococcal meningitis. Among 5,618 participants enrolled, 1,296 were HIV-infected and screened for cryptococcal antigenemia. Overall CrAg prevalence by serum EIA was 3.6% (95% CI 2.0–6.0%) for adults with CD4 < 200 cells/mm(3), and 5.7% (95% CI 2.8–10.2%) for adults with CD4 < 100 cells/mm(3). Using expanded screening guidelines (CD4 < 200 cells/mm(3)), CrAg LFA testing of venous whole blood, fingerprick capillary blood, and urine had diagnostic sensitivities of 46% (95% CI 19–75%), 38% (95% CI 14–68%), and 54% (95% CI 25–81%), and specificities of 97%, 97%, and 86%, respectively. When tested on serum samples, CrAg LFA had sensitivity of 93% (95% CI 66–100%) and specificity of 100% (95% CI 88–100%). All venous and fingerprick whole blood CrAg LFA tests were positive among 30 hospitalized adults with cryptococcal meningitis. Two independent readers had strong agreement for all LFA results (p < 0.0001). When performed at the point-of-care by trained nurses, CrAg LFA testing was feasible, had the highest accuracy on serum specimens, and may accelerate treatment of HIV-associated cryptococcal infections. |
---|