Cargando…

Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)

BACKGROUND: Thromboembolic events are a major cause of heart attacks and strokes. However, diagnosis of the location of high risk vascular clots is hampered by lack of proper technologies for their detection. We recently reported on bio-engineered fluorescent diamond-(NV)-Z~800nm (FNDP-(NV)) conjuga...

Descripción completa

Detalles Bibliográficos
Autores principales: Barone, Frank C, Marcinkiewicz, Cezary, Li, Jie, Feng, Yi, Sternberg, Mark, Lelkes, Peter I, Rosenbaum-Halevi, David, Gerstenhaber, Jonathan A, Feuerstein, Giora Z
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6391148/
https://www.ncbi.nlm.nih.gov/pubmed/30863052
http://dx.doi.org/10.2147/IJN.S189048
_version_ 1783398259241254912
author Barone, Frank C
Marcinkiewicz, Cezary
Li, Jie
Feng, Yi
Sternberg, Mark
Lelkes, Peter I
Rosenbaum-Halevi, David
Gerstenhaber, Jonathan A
Feuerstein, Giora Z
author_facet Barone, Frank C
Marcinkiewicz, Cezary
Li, Jie
Feng, Yi
Sternberg, Mark
Lelkes, Peter I
Rosenbaum-Halevi, David
Gerstenhaber, Jonathan A
Feuerstein, Giora Z
author_sort Barone, Frank C
collection PubMed
description BACKGROUND: Thromboembolic events are a major cause of heart attacks and strokes. However, diagnosis of the location of high risk vascular clots is hampered by lack of proper technologies for their detection. We recently reported on bio-engineered fluorescent diamond-(NV)-Z~800nm (FNDP-(NV)) conjugated with bitistatin (Bit) and proven its ability to identify iatrogenic blood clots in the rat carotid artery in vivo by Near Infra-Red (NIR) monitored by In Vivo Imaging System (IVIS). PURPOSE: The objective of the present research was to assess the in vivo biocompatibility of FNDP-(NV)-Z~800nm infused intravenously to rats. Multiple biological variables were assessed along this 12 week study commissioned in anticipation of regulatory requirements for a long-term safety assessment. METHODS: Rats were infused under anesthesia with aforementioned dose of the FNDP-(NV), while equal number of animals served as control (vehicle treated). Over the 12 week observation period rats were tested for thriving, motor, sensory and cognitive functions. At the termination of study, blood samples were obtained under anesthesia for comprehensive hematology and biochemical assays. Furthermore, 6 whole organs (liver, spleen, brain, heart, lung and kidney) were collected and examined ex vivo for FNDP-NV) via NIR monitored by IVIS and histochemical inspection. RESULTS: All animals survived, thrived (no change in body and organ growth). Neuro-behavioral functions remain intact. Hematology and biochemistry (including liver and kidney functions) were normal. Preferential FNDP-(NV) distribution identified the liver as the main long-term repository. Certified pathology reports indicated no outstanding of finding in all organs. CONCLUSION: The present study suggests outstanding biocompatibility of FNDP-(NV)-Z~800nm after long-term exposure in the rat.
format Online
Article
Text
id pubmed-6391148
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-63911482019-03-12 Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV) Barone, Frank C Marcinkiewicz, Cezary Li, Jie Feng, Yi Sternberg, Mark Lelkes, Peter I Rosenbaum-Halevi, David Gerstenhaber, Jonathan A Feuerstein, Giora Z Int J Nanomedicine Original Research BACKGROUND: Thromboembolic events are a major cause of heart attacks and strokes. However, diagnosis of the location of high risk vascular clots is hampered by lack of proper technologies for their detection. We recently reported on bio-engineered fluorescent diamond-(NV)-Z~800nm (FNDP-(NV)) conjugated with bitistatin (Bit) and proven its ability to identify iatrogenic blood clots in the rat carotid artery in vivo by Near Infra-Red (NIR) monitored by In Vivo Imaging System (IVIS). PURPOSE: The objective of the present research was to assess the in vivo biocompatibility of FNDP-(NV)-Z~800nm infused intravenously to rats. Multiple biological variables were assessed along this 12 week study commissioned in anticipation of regulatory requirements for a long-term safety assessment. METHODS: Rats were infused under anesthesia with aforementioned dose of the FNDP-(NV), while equal number of animals served as control (vehicle treated). Over the 12 week observation period rats were tested for thriving, motor, sensory and cognitive functions. At the termination of study, blood samples were obtained under anesthesia for comprehensive hematology and biochemical assays. Furthermore, 6 whole organs (liver, spleen, brain, heart, lung and kidney) were collected and examined ex vivo for FNDP-NV) via NIR monitored by IVIS and histochemical inspection. RESULTS: All animals survived, thrived (no change in body and organ growth). Neuro-behavioral functions remain intact. Hematology and biochemistry (including liver and kidney functions) were normal. Preferential FNDP-(NV) distribution identified the liver as the main long-term repository. Certified pathology reports indicated no outstanding of finding in all organs. CONCLUSION: The present study suggests outstanding biocompatibility of FNDP-(NV)-Z~800nm after long-term exposure in the rat. Dove Medical Press 2019-02-14 /pmc/articles/PMC6391148/ /pubmed/30863052 http://dx.doi.org/10.2147/IJN.S189048 Text en © 2019 Barone et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Barone, Frank C
Marcinkiewicz, Cezary
Li, Jie
Feng, Yi
Sternberg, Mark
Lelkes, Peter I
Rosenbaum-Halevi, David
Gerstenhaber, Jonathan A
Feuerstein, Giora Z
Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title_full Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title_fullStr Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title_full_unstemmed Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title_short Long-term biocompatibility of fluorescent diamonds-(NV)-Z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part IV)
title_sort long-term biocompatibility of fluorescent diamonds-(nv)-z~800 nm in rats: survival, morbidity, histopathology, particle distribution and excretion studies (part iv)
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6391148/
https://www.ncbi.nlm.nih.gov/pubmed/30863052
http://dx.doi.org/10.2147/IJN.S189048
work_keys_str_mv AT baronefrankc longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT marcinkiewiczcezary longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT lijie longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT fengyi longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT sternbergmark longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT lelkespeteri longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT rosenbaumhalevidavid longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT gerstenhaberjonathana longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv
AT feuersteingioraz longtermbiocompatibilityoffluorescentdiamondsnvz800nminratssurvivalmorbidityhistopathologyparticledistributionandexcretionstudiespartiv