No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial

Objective: The primary aim of this study was to longitudinally compare the behavioral and self-reported outcomes of simultaneous bilateral cochlear implantation (simBiCI) and sequential BiCI (seqBiCI) in adults with severe-to-profound postlingual sensorineural hearing loss. Design: This study is a m...

Descripción completa

Detalles Bibliográficos
Autores principales: Kraaijenga, Véronique J. C., Ramakers, Geerte G. J., Smulders, Yvette E., van Zon, Alice, Free, Rolien H., Frijns, Johan H. M., Huinck, Wendy J., Stokroos, Robert J., Grolman, Wilko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6391354/
https://www.ncbi.nlm.nih.gov/pubmed/30842721
http://dx.doi.org/10.3389/fnins.2019.00054
_version_ 1783398278552879104
author Kraaijenga, Véronique J. C.
Ramakers, Geerte G. J.
Smulders, Yvette E.
van Zon, Alice
Free, Rolien H.
Frijns, Johan H. M.
Huinck, Wendy J.
Stokroos, Robert J.
Grolman, Wilko
author_facet Kraaijenga, Véronique J. C.
Ramakers, Geerte G. J.
Smulders, Yvette E.
van Zon, Alice
Free, Rolien H.
Frijns, Johan H. M.
Huinck, Wendy J.
Stokroos, Robert J.
Grolman, Wilko
author_sort Kraaijenga, Véronique J. C.
collection PubMed
description Objective: The primary aim of this study was to longitudinally compare the behavioral and self-reported outcomes of simultaneous bilateral cochlear implantation (simBiCI) and sequential BiCI (seqBiCI) in adults with severe-to-profound postlingual sensorineural hearing loss. Design: This study is a multicenter randomized controlled trial with a 4-year follow-up period after the first moment of implantation. Participants were allocated by randomization to receive bilateral cochlear implants (CIs) either, simultaneously (simBiCI group) or sequentially with an inter-implant interval of 2 years (UCI/seqBiCI group). All sequential patients where encouraged to use their hearing aid on the non-implanted ear over of the first 2 years. Patients were followed-up on an annual basis. The primary outcome was speech perception in noise coming from a source directly in front of the patient. Other behavioral outcome measures were speech intelligibility-in-noise from spatially separated sources, localization and speech perception in quiet. Self-reported outcome measures encompassed questionnaires on quality of life, quality of hearing and tinnitus. All outcome measures were analyzed longitudinally using a linear or logistic regression analysis with an autoregressive residual covariance matrix (generalized estimating equations type). Results: Nineteen participants were randomly allocated to the simBiCI group and 19 participants to the UCI/seqBiCI group. Three participants in the UCI/seqBiCI group did not proceed with their second implantation and were therefore unavailable for follow-up. Both study groups performed equally well on speech perception in noise from a source directly in front of the patient longitudinally. During all 4 years of follow-up the UCI/seqBiCI group performed significantly worse compared to the simBiCI group on spatial speech perception in noise in the best performance situation (8.70 dB [3.96 – 13.44], p < 0.001) and localization abilities (largest difference 60 degrees configuration: -44.45% [-52.15 – -36.74], p < 0.0001). Furthermore, during all years of follow-up, the UCI/seqBiCI group performed significantly worse on quality of hearing and quality of life questionnaires. The years of unilateral CI use were the reason for the inferior results in the UCI/SeqBiCI group. One year after receiving CI2, the UCI/seqBiCI group performance did not statistically differ from the performance of the simBiCI group on all these outcomes. Furthermore, no longitudinal differences were seen in tinnitus burden prevalence between groups. Finally, the complications that occurred during this trial were infection, dysfunction of CI, facial nerve palsy, tinnitus and vertigo. Conclusion: This randomized controlled trial on bilaterally severely hearing impaired participants found a significantly worse longitudinal performance of UCI/seqBiCI compared to simBiCI on multiple behavioral and self-reported outcomes regarding speech perception in noise and localization abilities. This difference is associated with the inferior performance of the UCI/seqBiCI participants during the years of unilateral CI use. After receiving the second CI however, the performance of the UCI/seqBiCI group did not significantly differ from the simBiCI group. Trial Registration: Dutch Trial Register NTR1722.
format Online
Article
Text
id pubmed-6391354
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-63913542019-03-06 No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial Kraaijenga, Véronique J. C. Ramakers, Geerte G. J. Smulders, Yvette E. van Zon, Alice Free, Rolien H. Frijns, Johan H. M. Huinck, Wendy J. Stokroos, Robert J. Grolman, Wilko Front Neurosci Neuroscience Objective: The primary aim of this study was to longitudinally compare the behavioral and self-reported outcomes of simultaneous bilateral cochlear implantation (simBiCI) and sequential BiCI (seqBiCI) in adults with severe-to-profound postlingual sensorineural hearing loss. Design: This study is a multicenter randomized controlled trial with a 4-year follow-up period after the first moment of implantation. Participants were allocated by randomization to receive bilateral cochlear implants (CIs) either, simultaneously (simBiCI group) or sequentially with an inter-implant interval of 2 years (UCI/seqBiCI group). All sequential patients where encouraged to use their hearing aid on the non-implanted ear over of the first 2 years. Patients were followed-up on an annual basis. The primary outcome was speech perception in noise coming from a source directly in front of the patient. Other behavioral outcome measures were speech intelligibility-in-noise from spatially separated sources, localization and speech perception in quiet. Self-reported outcome measures encompassed questionnaires on quality of life, quality of hearing and tinnitus. All outcome measures were analyzed longitudinally using a linear or logistic regression analysis with an autoregressive residual covariance matrix (generalized estimating equations type). Results: Nineteen participants were randomly allocated to the simBiCI group and 19 participants to the UCI/seqBiCI group. Three participants in the UCI/seqBiCI group did not proceed with their second implantation and were therefore unavailable for follow-up. Both study groups performed equally well on speech perception in noise from a source directly in front of the patient longitudinally. During all 4 years of follow-up the UCI/seqBiCI group performed significantly worse compared to the simBiCI group on spatial speech perception in noise in the best performance situation (8.70 dB [3.96 – 13.44], p < 0.001) and localization abilities (largest difference 60 degrees configuration: -44.45% [-52.15 – -36.74], p < 0.0001). Furthermore, during all years of follow-up, the UCI/seqBiCI group performed significantly worse on quality of hearing and quality of life questionnaires. The years of unilateral CI use were the reason for the inferior results in the UCI/SeqBiCI group. One year after receiving CI2, the UCI/seqBiCI group performance did not statistically differ from the performance of the simBiCI group on all these outcomes. Furthermore, no longitudinal differences were seen in tinnitus burden prevalence between groups. Finally, the complications that occurred during this trial were infection, dysfunction of CI, facial nerve palsy, tinnitus and vertigo. Conclusion: This randomized controlled trial on bilaterally severely hearing impaired participants found a significantly worse longitudinal performance of UCI/seqBiCI compared to simBiCI on multiple behavioral and self-reported outcomes regarding speech perception in noise and localization abilities. This difference is associated with the inferior performance of the UCI/seqBiCI participants during the years of unilateral CI use. After receiving the second CI however, the performance of the UCI/seqBiCI group did not significantly differ from the simBiCI group. Trial Registration: Dutch Trial Register NTR1722. Frontiers Media S.A. 2019-02-20 /pmc/articles/PMC6391354/ /pubmed/30842721 http://dx.doi.org/10.3389/fnins.2019.00054 Text en Copyright © 2019 Kraaijenga, Ramakers, Smulders, van Zon, Free, Frijns, Huinck, Stokroos and Grolman. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Kraaijenga, Véronique J. C.
Ramakers, Geerte G. J.
Smulders, Yvette E.
van Zon, Alice
Free, Rolien H.
Frijns, Johan H. M.
Huinck, Wendy J.
Stokroos, Robert J.
Grolman, Wilko
No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title_full No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title_fullStr No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title_full_unstemmed No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title_short No Difference in Behavioral and Self-Reported Outcomes for Simultaneous and Sequential Bilateral Cochlear Implantation: Evidence From a Multicenter Randomized Controlled Trial
title_sort no difference in behavioral and self-reported outcomes for simultaneous and sequential bilateral cochlear implantation: evidence from a multicenter randomized controlled trial
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6391354/
https://www.ncbi.nlm.nih.gov/pubmed/30842721
http://dx.doi.org/10.3389/fnins.2019.00054
work_keys_str_mv AT kraaijengaveroniquejc nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT ramakersgeertegj nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT smuldersyvettee nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT vanzonalice nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT freerolienh nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT frijnsjohanhm nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT huinckwendyj nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT stokroosrobertj nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial
AT grolmanwilko nodifferenceinbehavioralandselfreportedoutcomesforsimultaneousandsequentialbilateralcochlearimplantationevidencefromamulticenterrandomizedcontrolledtrial