Cargando…
Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft
BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation is an established treatment option to management the complications of portal hypertension. Recent data on the long-term outcomes of TIPS are scarce. MATERIALS AND METHODS: In this single-institution retrospective study, 495 pa...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6392293/ https://www.ncbi.nlm.nih.gov/pubmed/30811467 http://dx.doi.org/10.1371/journal.pone.0212658 |
_version_ | 1783398449440358400 |
---|---|
author | Luo, Xuefeng Zhao, Ming Wang, Xiaoze Jiang, Mingshan Yu, Jiaze Li, Xiao Yang, Li |
author_facet | Luo, Xuefeng Zhao, Ming Wang, Xiaoze Jiang, Mingshan Yu, Jiaze Li, Xiao Yang, Li |
author_sort | Luo, Xuefeng |
collection | PubMed |
description | BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation is an established treatment option to management the complications of portal hypertension. Recent data on the long-term outcomes of TIPS are scarce. MATERIALS AND METHODS: In this single-institution retrospective study, 495 patients underwent TIPS with the Fluency stent-grafts between December 2011 and June 2015 were evaluated. The cumulative rates of TIPS dysfunction, hepatic encephalopathy (HE), survival, and variceal rebleeding were determined using the Kaplan–Meier method. Cox regression analysis was used to assess the parameters on TIPS patency, occurrence of HE and all-cause mortality. RESULTS: Technical success was 98.2%. TIPS-related complications occurred in 67 patients (13.5%) during the index hospital stay. TIPS creation resulted in an immediate decrease in mean portosystemic pressure gradient from 23.4 ± 7.1 mmHg to 7.6 ± 3.5 mmHg. The median follow-up period was 649 days. Primary TIPS patency rates were 93%, and 75.9% at 1 and 3 years, respectively. Previous splenectomy was associated with a higher risk of TPS dysfunction. The cumulative survival rates were 93.4% and 77.2% at 1 and 3 years, respectively. The 1- and 3-year probability of remaining free of variceal bleeding rates were 94.2% and 71.4%, respectively. CONCLUSIONS: This retrospective single-center experience with TIPS using the Fluency stent-grafts demonstrates good long-term patency and favorable good clinical results. Previous splenectomy strongly predicts shunt dysfunction. |
format | Online Article Text |
id | pubmed-6392293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-63922932019-03-08 Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft Luo, Xuefeng Zhao, Ming Wang, Xiaoze Jiang, Mingshan Yu, Jiaze Li, Xiao Yang, Li PLoS One Research Article BACKGROUND: Transjugular intrahepatic portosystemic shunt (TIPS) creation is an established treatment option to management the complications of portal hypertension. Recent data on the long-term outcomes of TIPS are scarce. MATERIALS AND METHODS: In this single-institution retrospective study, 495 patients underwent TIPS with the Fluency stent-grafts between December 2011 and June 2015 were evaluated. The cumulative rates of TIPS dysfunction, hepatic encephalopathy (HE), survival, and variceal rebleeding were determined using the Kaplan–Meier method. Cox regression analysis was used to assess the parameters on TIPS patency, occurrence of HE and all-cause mortality. RESULTS: Technical success was 98.2%. TIPS-related complications occurred in 67 patients (13.5%) during the index hospital stay. TIPS creation resulted in an immediate decrease in mean portosystemic pressure gradient from 23.4 ± 7.1 mmHg to 7.6 ± 3.5 mmHg. The median follow-up period was 649 days. Primary TIPS patency rates were 93%, and 75.9% at 1 and 3 years, respectively. Previous splenectomy was associated with a higher risk of TPS dysfunction. The cumulative survival rates were 93.4% and 77.2% at 1 and 3 years, respectively. The 1- and 3-year probability of remaining free of variceal bleeding rates were 94.2% and 71.4%, respectively. CONCLUSIONS: This retrospective single-center experience with TIPS using the Fluency stent-grafts demonstrates good long-term patency and favorable good clinical results. Previous splenectomy strongly predicts shunt dysfunction. Public Library of Science 2019-02-27 /pmc/articles/PMC6392293/ /pubmed/30811467 http://dx.doi.org/10.1371/journal.pone.0212658 Text en © 2019 Luo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Luo, Xuefeng Zhao, Ming Wang, Xiaoze Jiang, Mingshan Yu, Jiaze Li, Xiao Yang, Li Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title | Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title_full | Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title_fullStr | Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title_full_unstemmed | Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title_short | Long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
title_sort | long-term patency and clinical outcome of the transjugular intrahepatic portosystemic shunt using the expanded polytetrafluoroethylene stent-graft |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6392293/ https://www.ncbi.nlm.nih.gov/pubmed/30811467 http://dx.doi.org/10.1371/journal.pone.0212658 |
work_keys_str_mv | AT luoxuefeng longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT zhaoming longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT wangxiaoze longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT jiangmingshan longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT yujiaze longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT lixiao longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft AT yangli longtermpatencyandclinicaloutcomeofthetransjugularintrahepaticportosystemicshuntusingtheexpandedpolytetrafluoroethylenestentgraft |