Cargando…
Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study
The objective of this study is to evaluate the stress distribution characteristics around three different dental implant designs during insertion into bone, using dynamic finite element stress analysis. Dental implant placement was simulated using finite element models. Three implants with different...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6392841/ https://www.ncbi.nlm.nih.gov/pubmed/30847230 http://dx.doi.org/10.1002/cre2.152 |
_version_ | 1783398565152817152 |
---|---|
author | Udomsawat, Chaiwat Rungsiyakull, Pimduen Rungsiyakull, Chaiy Khongkhunthian, Pathawee |
author_facet | Udomsawat, Chaiwat Rungsiyakull, Pimduen Rungsiyakull, Chaiy Khongkhunthian, Pathawee |
author_sort | Udomsawat, Chaiwat |
collection | PubMed |
description | The objective of this study is to evaluate the stress distribution characteristics around three different dental implant designs during insertion into bone, using dynamic finite element stress analysis. Dental implant placement was simulated using finite element models. Three implants with different thread and body designs (Model 1: root form implant with three different thread shapes; Model 2: tapered implant with a double‐lead thread; and Model 3: conical tapered implant with a constant buttress thread) were assigned to insert into prepared bone cavity models until completely placed. Stress and strain distributions were descriptively analyzed. The von Mises stresses within the surrounding bone were measured. At the first 4‐mm depth of implant insertion, maximum stress within cortical bone for Model 3 (175 MPa) was less than the other models (180 MPa each). Stress values and concentration area were increasing whereas insertion depth increased. At full implant insertion depth, maximum stress level in Model 1 (35 MPa) within the cancellous bone was slightly greater than in Models 2 (30 MPa) and 3 (25 MPa), respectively. Generally, for all simulations, the highest stress value and the location of the stress concentration area were mostly in cortical bone. However, the stress distribution patterns during the insertion process were different between the models depending on the different designs geometry that contacted the surrounding bone. Different implant designs affect different stress generation patterns during implant insertion. A range of stress magnitude, generated in the surrounding bone, may influence bone healing around dental implants and final implant stability. |
format | Online Article Text |
id | pubmed-6392841 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-63928412019-03-07 Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study Udomsawat, Chaiwat Rungsiyakull, Pimduen Rungsiyakull, Chaiy Khongkhunthian, Pathawee Clin Exp Dent Res Original Articles The objective of this study is to evaluate the stress distribution characteristics around three different dental implant designs during insertion into bone, using dynamic finite element stress analysis. Dental implant placement was simulated using finite element models. Three implants with different thread and body designs (Model 1: root form implant with three different thread shapes; Model 2: tapered implant with a double‐lead thread; and Model 3: conical tapered implant with a constant buttress thread) were assigned to insert into prepared bone cavity models until completely placed. Stress and strain distributions were descriptively analyzed. The von Mises stresses within the surrounding bone were measured. At the first 4‐mm depth of implant insertion, maximum stress within cortical bone for Model 3 (175 MPa) was less than the other models (180 MPa each). Stress values and concentration area were increasing whereas insertion depth increased. At full implant insertion depth, maximum stress level in Model 1 (35 MPa) within the cancellous bone was slightly greater than in Models 2 (30 MPa) and 3 (25 MPa), respectively. Generally, for all simulations, the highest stress value and the location of the stress concentration area were mostly in cortical bone. However, the stress distribution patterns during the insertion process were different between the models depending on the different designs geometry that contacted the surrounding bone. Different implant designs affect different stress generation patterns during implant insertion. A range of stress magnitude, generated in the surrounding bone, may influence bone healing around dental implants and final implant stability. John Wiley and Sons Inc. 2018-12-26 /pmc/articles/PMC6392841/ /pubmed/30847230 http://dx.doi.org/10.1002/cre2.152 Text en ©2018 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Udomsawat, Chaiwat Rungsiyakull, Pimduen Rungsiyakull, Chaiy Khongkhunthian, Pathawee Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title | Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title_full | Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title_fullStr | Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title_full_unstemmed | Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title_short | Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three‐dimensional dynamic finite element study |
title_sort | comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: a three‐dimensional dynamic finite element study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6392841/ https://www.ncbi.nlm.nih.gov/pubmed/30847230 http://dx.doi.org/10.1002/cre2.152 |
work_keys_str_mv | AT udomsawatchaiwat comparativestudyofstresscharacteristicsinsurroundingboneduringinsertionofdentalimplantsofthreedifferentthreaddesignsathreedimensionaldynamicfiniteelementstudy AT rungsiyakullpimduen comparativestudyofstresscharacteristicsinsurroundingboneduringinsertionofdentalimplantsofthreedifferentthreaddesignsathreedimensionaldynamicfiniteelementstudy AT rungsiyakullchaiy comparativestudyofstresscharacteristicsinsurroundingboneduringinsertionofdentalimplantsofthreedifferentthreaddesignsathreedimensionaldynamicfiniteelementstudy AT khongkhunthianpathawee comparativestudyofstresscharacteristicsinsurroundingboneduringinsertionofdentalimplantsofthreedifferentthreaddesignsathreedimensionaldynamicfiniteelementstudy |