Cargando…

Comparison between Right and Left Upper Arms in Detection of Hypertension

BACKGROUND AND OBJECTIVES: This study aimed to investigate the right-left arm difference in detection of hypertension in the general Korean population. METHODS: This study analyzed data from the Cardiovascular and Metabolic Disease Etiology Research Center cohort. Study population was 2,103 people w...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Bo Mi, Kim, Hyeon Chang, Shim, Jee-Seon, Kang, Dae Ryong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393325/
https://www.ncbi.nlm.nih.gov/pubmed/30468034
http://dx.doi.org/10.4070/kcj.2018.0147
_version_ 1783398663021658112
author Song, Bo Mi
Kim, Hyeon Chang
Shim, Jee-Seon
Kang, Dae Ryong
author_facet Song, Bo Mi
Kim, Hyeon Chang
Shim, Jee-Seon
Kang, Dae Ryong
author_sort Song, Bo Mi
collection PubMed
description BACKGROUND AND OBJECTIVES: This study aimed to investigate the right-left arm difference in detection of hypertension in the general Korean population. METHODS: This study analyzed data from the Cardiovascular and Metabolic Disease Etiology Research Center cohort. Study population was 2,103 people who were aged 30 to 64 years old, without history of major cardiovascular diseases, and did not use antihypertensive medication. Brachial blood pressures (BPs) were measured for both arms using an automated oscillometric device equipped with 2 cuffs for simultaneous double-arm measurements. Systolic and diastolic blood pressures (SBP and DBP) were measured 3 times, and the average value was used in the analysis. Overall hypertension was defined as elevated blood pressure (SBP/DBP ≥140/90 mmHg) at the arm with higher value, while right-arm or left-arm hypertension was defined as elevated BP at each arm. Sensitivity was calculated as the number of each-arm hypertension divided by the number of overall hypertension. RESULTS: Overall 8.6% of the population had hypertension at either arm, while 7.8% had right-arm hypertension, 7.2% had left-arm hypertension, and 6.4% had both arms hypertension. The sensitivity for the detection of hypertension was 90.6% when BP was measured only at right arm, and 83.4% when measured only at left arm. Corresponding sensitivity were 87.9% and 87.1% in men, and 95.4% and 76.9% in women. CONCLUSIONS: Single-arm measurements, compared to double-arm measurements, may underestimate the prevalence of hypertension. However, if double-arm measurements are unavailable, right arm is preferred for measurement of BP, especially in women.
format Online
Article
Text
id pubmed-6393325
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-63933252019-03-06 Comparison between Right and Left Upper Arms in Detection of Hypertension Song, Bo Mi Kim, Hyeon Chang Shim, Jee-Seon Kang, Dae Ryong Korean Circ J Original Article BACKGROUND AND OBJECTIVES: This study aimed to investigate the right-left arm difference in detection of hypertension in the general Korean population. METHODS: This study analyzed data from the Cardiovascular and Metabolic Disease Etiology Research Center cohort. Study population was 2,103 people who were aged 30 to 64 years old, without history of major cardiovascular diseases, and did not use antihypertensive medication. Brachial blood pressures (BPs) were measured for both arms using an automated oscillometric device equipped with 2 cuffs for simultaneous double-arm measurements. Systolic and diastolic blood pressures (SBP and DBP) were measured 3 times, and the average value was used in the analysis. Overall hypertension was defined as elevated blood pressure (SBP/DBP ≥140/90 mmHg) at the arm with higher value, while right-arm or left-arm hypertension was defined as elevated BP at each arm. Sensitivity was calculated as the number of each-arm hypertension divided by the number of overall hypertension. RESULTS: Overall 8.6% of the population had hypertension at either arm, while 7.8% had right-arm hypertension, 7.2% had left-arm hypertension, and 6.4% had both arms hypertension. The sensitivity for the detection of hypertension was 90.6% when BP was measured only at right arm, and 83.4% when measured only at left arm. Corresponding sensitivity were 87.9% and 87.1% in men, and 95.4% and 76.9% in women. CONCLUSIONS: Single-arm measurements, compared to double-arm measurements, may underestimate the prevalence of hypertension. However, if double-arm measurements are unavailable, right arm is preferred for measurement of BP, especially in women. The Korean Society of Cardiology 2018-10-23 /pmc/articles/PMC6393325/ /pubmed/30468034 http://dx.doi.org/10.4070/kcj.2018.0147 Text en Copyright © 2019. The Korean Society of Cardiology https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Song, Bo Mi
Kim, Hyeon Chang
Shim, Jee-Seon
Kang, Dae Ryong
Comparison between Right and Left Upper Arms in Detection of Hypertension
title Comparison between Right and Left Upper Arms in Detection of Hypertension
title_full Comparison between Right and Left Upper Arms in Detection of Hypertension
title_fullStr Comparison between Right and Left Upper Arms in Detection of Hypertension
title_full_unstemmed Comparison between Right and Left Upper Arms in Detection of Hypertension
title_short Comparison between Right and Left Upper Arms in Detection of Hypertension
title_sort comparison between right and left upper arms in detection of hypertension
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393325/
https://www.ncbi.nlm.nih.gov/pubmed/30468034
http://dx.doi.org/10.4070/kcj.2018.0147
work_keys_str_mv AT songbomi comparisonbetweenrightandleftupperarmsindetectionofhypertension
AT kimhyeonchang comparisonbetweenrightandleftupperarmsindetectionofhypertension
AT shimjeeseon comparisonbetweenrightandleftupperarmsindetectionofhypertension
AT kangdaeryong comparisonbetweenrightandleftupperarmsindetectionofhypertension