Cargando…
Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence
The presence of hepatic steatosis (HS) is an important histological feature in a variety of liver disease. It is critical to assess HS accurately, particularly where it plays an integral part in defining the disease. Conventional methods of quantifying HS remain semi-quantitative, with potential lim...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393558/ https://www.ncbi.nlm.nih.gov/pubmed/30814650 http://dx.doi.org/10.1038/s41598-019-39783-1 |
_version_ | 1783398718011080704 |
---|---|
author | Goh, George Boon-Bee Leow, Wei Qiang Liang, Shen Wan, Wei Keat Lim, Tony Kiat Hon Tan, Chee Kiat Chang, Pik Eu |
author_facet | Goh, George Boon-Bee Leow, Wei Qiang Liang, Shen Wan, Wei Keat Lim, Tony Kiat Hon Tan, Chee Kiat Chang, Pik Eu |
author_sort | Goh, George Boon-Bee |
collection | PubMed |
description | The presence of hepatic steatosis (HS) is an important histological feature in a variety of liver disease. It is critical to assess HS accurately, particularly where it plays an integral part in defining the disease. Conventional methods of quantifying HS remain semi-quantitative, with potential limitations in precision, accuracy and subjectivity. Second Harmonic Generation (SHG) microscopy is a novel technology using multiphoton imaging techniques with applicability in histological tissue assessment. Using an automated algorithm based on signature SHG parameters, we explored the utility and application of SHG for the diagnosis and quantification of HS. SHG microscopy analysis using GENESIS (HistoIndex, Singapore) was applied on 86 archived liver biopsy samples. Reliability was correlated with 3 liver histopathologists. Data analysis was performed using SPSS. There was minimal inter-observer variability between the 3 liver histopathologists, with an intraclass correlation of 0.92 (95% CI 0.89–0.95; p < 0.001). Good correlation was observed between the histopathologists and automated SHG microscopy assessment of HS with Pearson correlation of 0.93: p < 0.001. SHG microscopy provides a valuable tool for objective, more precise measure of HS using an automated approach. Our study reflects proof of concept evidence for potential future refinement to current conventional histological assessment. |
format | Online Article Text |
id | pubmed-6393558 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-63935582019-03-01 Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence Goh, George Boon-Bee Leow, Wei Qiang Liang, Shen Wan, Wei Keat Lim, Tony Kiat Hon Tan, Chee Kiat Chang, Pik Eu Sci Rep Article The presence of hepatic steatosis (HS) is an important histological feature in a variety of liver disease. It is critical to assess HS accurately, particularly where it plays an integral part in defining the disease. Conventional methods of quantifying HS remain semi-quantitative, with potential limitations in precision, accuracy and subjectivity. Second Harmonic Generation (SHG) microscopy is a novel technology using multiphoton imaging techniques with applicability in histological tissue assessment. Using an automated algorithm based on signature SHG parameters, we explored the utility and application of SHG for the diagnosis and quantification of HS. SHG microscopy analysis using GENESIS (HistoIndex, Singapore) was applied on 86 archived liver biopsy samples. Reliability was correlated with 3 liver histopathologists. Data analysis was performed using SPSS. There was minimal inter-observer variability between the 3 liver histopathologists, with an intraclass correlation of 0.92 (95% CI 0.89–0.95; p < 0.001). Good correlation was observed between the histopathologists and automated SHG microscopy assessment of HS with Pearson correlation of 0.93: p < 0.001. SHG microscopy provides a valuable tool for objective, more precise measure of HS using an automated approach. Our study reflects proof of concept evidence for potential future refinement to current conventional histological assessment. Nature Publishing Group UK 2019-02-27 /pmc/articles/PMC6393558/ /pubmed/30814650 http://dx.doi.org/10.1038/s41598-019-39783-1 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Goh, George Boon-Bee Leow, Wei Qiang Liang, Shen Wan, Wei Keat Lim, Tony Kiat Hon Tan, Chee Kiat Chang, Pik Eu Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title | Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title_full | Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title_fullStr | Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title_full_unstemmed | Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title_short | Quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
title_sort | quantification of hepatic steatosis in chronic liver disease using novel automated method of second harmonic generation and two-photon excited fluorescence |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393558/ https://www.ncbi.nlm.nih.gov/pubmed/30814650 http://dx.doi.org/10.1038/s41598-019-39783-1 |
work_keys_str_mv | AT gohgeorgeboonbee quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT leowweiqiang quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT liangshen quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT wanweikeat quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT limtonykiathon quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT tancheekiat quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence AT changpikeu quantificationofhepaticsteatosisinchronicliverdiseaseusingnovelautomatedmethodofsecondharmonicgenerationandtwophotonexcitedfluorescence |