Cargando…
Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+
BACKGROUND: Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393958/ https://www.ncbi.nlm.nih.gov/pubmed/30819148 http://dx.doi.org/10.1186/s12889-019-6568-9 |
_version_ | 1783398792443199488 |
---|---|
author | Knaier, Raphael Höchsmann, Christoph Infanger, Denis Hinrichs, Timo Schmidt-Trucksäss, Arno |
author_facet | Knaier, Raphael Höchsmann, Christoph Infanger, Denis Hinrichs, Timo Schmidt-Trucksäss, Arno |
author_sort | Knaier, Raphael |
collection | PubMed |
description | BACKGROUND: Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting. METHODS: Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings. RESULTS: Mean wear time was over 1420 min per day for both devices on all days. Lin’s concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were − 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were − 17.5 ± 10% in Troiano and − 0.8 ± 4.6% in Choi. CONCLUSIONS: Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level. |
format | Online Article Text |
id | pubmed-6393958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-63939582019-03-11 Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ Knaier, Raphael Höchsmann, Christoph Infanger, Denis Hinrichs, Timo Schmidt-Trucksäss, Arno BMC Public Health Research Article BACKGROUND: Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting. METHODS: Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings. RESULTS: Mean wear time was over 1420 min per day for both devices on all days. Lin’s concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were − 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were − 17.5 ± 10% in Troiano and − 0.8 ± 4.6% in Choi. CONCLUSIONS: Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level. BioMed Central 2019-02-28 /pmc/articles/PMC6393958/ /pubmed/30819148 http://dx.doi.org/10.1186/s12889-019-6568-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Knaier, Raphael Höchsmann, Christoph Infanger, Denis Hinrichs, Timo Schmidt-Trucksäss, Arno Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title | Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title_full | Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title_fullStr | Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title_full_unstemmed | Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title_short | Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X+ |
title_sort | validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn actigraph gt3x+ |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6393958/ https://www.ncbi.nlm.nih.gov/pubmed/30819148 http://dx.doi.org/10.1186/s12889-019-6568-9 |
work_keys_str_mv | AT knaierraphael validationofautomaticweartimedetectionalgorithmsinafreelivingsettingofwristwornandhipwornactigraphgt3x AT hochsmannchristoph validationofautomaticweartimedetectionalgorithmsinafreelivingsettingofwristwornandhipwornactigraphgt3x AT infangerdenis validationofautomaticweartimedetectionalgorithmsinafreelivingsettingofwristwornandhipwornactigraphgt3x AT hinrichstimo validationofautomaticweartimedetectionalgorithmsinafreelivingsettingofwristwornandhipwornactigraphgt3x AT schmidttrucksassarno validationofautomaticweartimedetectionalgorithmsinafreelivingsettingofwristwornandhipwornactigraphgt3x |