Cargando…
Endoscopist’s occupational dose evaluation related to correct wearing of dosimeter during X-ray-guided procedures
Background Since endoscopists performing procedures in the endoscopy suite can change their position by turning their back, side or front toward the X-ray source, this study aimed to establish whether dosimeter position affects the correct evaluation of an endoscopist’s personal radiation exposure...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2019
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6395086/ https://www.ncbi.nlm.nih.gov/pubmed/30834296 http://dx.doi.org/10.1055/a-0841-3350 |
Sumario: | Background Since endoscopists performing procedures in the endoscopy suite can change their position by turning their back, side or front toward the X-ray source, this study aimed to establish whether dosimeter position affects the correct evaluation of an endoscopist’s personal radiation exposure during X-ray-guided procedures. Materials and methods Between January and February 2018, two dosimeters specularly placed outside the lead apron (anterior one on the chest and posterior one on the back) measured endoscopists’ personal dose equivalent (Hp) during 62 X-ray-guided procedures on adult and pediatric patients. Procedures were divided into three groups considering the position taken by the endoscopist with respect to the radiation source. For each group, the difference between mean Hp from the anterior and posterior dosimeters was calculated. Results A statistically significant difference in mean Hp was recorded for the endoscopists’ frontal and back positions ( P = 0.014, and P < 0.00001, respectively). No significant difference was found in mean Hp for the side position ( P = 0.489). Conclusions The position of personal dosimeters affects the correct evaluation of endoscopists’ radiation exposure during X-ray-guided procedures when frontal and back positions were recorded. To correctly evaluate radiation doses, the whole-body dosimeter should be worn according to the position of the endoscopist with respect to the radiation source; otherwise, it results in an incorrect personal dose evaluation, which may lead to substantial underestimation of staff exposure. |
---|