Cargando…

Interfacial analysis of porcelain fused to high-palladium alloy with different observation methods

BACKGROUND/PURPOSE: In a previous fractural study of implant-supported crowns, it was found that the palladium−silver crowns possessed the highest fracture force. The ceramic–metal interface was examined to explain its high resistance to fracture. MATERIALS AND METHODS: Palladium−silver crowns with...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Hao-Sheng, Yang, Chao-Sen, Hsieh, Yao-Dung, Chen, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Association for Dental Sciences of the Republic of China 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6395158/
https://www.ncbi.nlm.nih.gov/pubmed/30894965
http://dx.doi.org/10.1016/j.jds.2015.10.001