Interfacial analysis of porcelain fused to high-palladium alloy with different observation methods

BACKGROUND/PURPOSE: In a previous fractural study of implant-supported crowns, it was found that the palladium−silver crowns possessed the highest fracture force. The ceramic–metal interface was examined to explain its high resistance to fracture. MATERIALS AND METHODS: Palladium−silver crowns with...