Cargando…
Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study
BACKGROUND: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is curre...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6396464/ https://www.ncbi.nlm.nih.gov/pubmed/30819131 http://dx.doi.org/10.1186/s12880-019-0308-6 |
_version_ | 1783399257081905152 |
---|---|
author | Viswanath, Satish E. Chirra, Prathyush V. Yim, Michael C. Rofsky, Neil M. Purysko, Andrei S. Rosen, Mark A. Bloch, B Nicolas Madabhushi, Anant |
author_facet | Viswanath, Satish E. Chirra, Prathyush V. Yim, Michael C. Rofsky, Neil M. Purysko, Andrei S. Rosen, Mark A. Bloch, B Nicolas Madabhushi, Anant |
author_sort | Viswanath, Satish E. |
collection | PubMed |
description | BACKGROUND: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is currently unknown how classifier choices and trends generalize across multiple institutions, due to heterogeneous acquisition and intensity characteristics (especially when considering MR imaging data). In this work, we empirically evaluate and compare a number of different classifiers and classifier ensembles in a multi-site setting, for voxel-wise detection of prostate cancer (PCa) using radiomic texture features derived from high-resolution in vivo T2-weighted (T2w) MRI. METHODS: Twelve different supervised classifier schemes: Quadratic Discriminant Analysis (QDA), Support Vector Machines (SVMs), naïve Bayes, Decision Trees (DTs), and their ensemble variants (bagging, boosting), were compared in terms of classification accuracy as well as execution time. Our study utilized 85 prostate cancer T2w MRI datasets acquired from across 3 different institutions (1 for discovery, 2 for independent validation), from patients who later underwent radical prostatectomy. Surrogate ground truth for disease extent on MRI was established by expert annotation of pre-operative MRI through spatial correlation with corresponding ex vivo whole-mount histology sections. Classifier accuracy in detecting PCa extent on MRI on a per-voxel basis was evaluated via area under the ROC curve. RESULTS: The boosted DT classifier yielded the highest cross-validated AUC (= 0.744) for detecting PCa in the discovery cohort. However, in independent validation, the boosted QDA classifier was identified as the most accurate and robust for voxel-wise detection of PCa extent (AUCs of 0.735, 0.683, 0.768 across the 3 sites). The next most accurate and robust classifier was the single QDA classifier, which also enjoyed the advantage of significantly lower computation times compared to any of the other methods. CONCLUSIONS: Our results therefore suggest that simpler classifiers (such as QDA and its ensemble variants) may be more robust, accurate, and efficient for prostate cancer CAD problems, especially in the context of multi-site validation. |
format | Online Article Text |
id | pubmed-6396464 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-63964642019-03-13 Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study Viswanath, Satish E. Chirra, Prathyush V. Yim, Michael C. Rofsky, Neil M. Purysko, Andrei S. Rosen, Mark A. Bloch, B Nicolas Madabhushi, Anant BMC Med Imaging Research Article BACKGROUND: For most computer-aided diagnosis (CAD) problems involving prostate cancer detection via medical imaging data, the choice of classifier has been largely ad hoc, or been motivated by classifier comparison studies that have involved large synthetic datasets. More significantly, it is currently unknown how classifier choices and trends generalize across multiple institutions, due to heterogeneous acquisition and intensity characteristics (especially when considering MR imaging data). In this work, we empirically evaluate and compare a number of different classifiers and classifier ensembles in a multi-site setting, for voxel-wise detection of prostate cancer (PCa) using radiomic texture features derived from high-resolution in vivo T2-weighted (T2w) MRI. METHODS: Twelve different supervised classifier schemes: Quadratic Discriminant Analysis (QDA), Support Vector Machines (SVMs), naïve Bayes, Decision Trees (DTs), and their ensemble variants (bagging, boosting), were compared in terms of classification accuracy as well as execution time. Our study utilized 85 prostate cancer T2w MRI datasets acquired from across 3 different institutions (1 for discovery, 2 for independent validation), from patients who later underwent radical prostatectomy. Surrogate ground truth for disease extent on MRI was established by expert annotation of pre-operative MRI through spatial correlation with corresponding ex vivo whole-mount histology sections. Classifier accuracy in detecting PCa extent on MRI on a per-voxel basis was evaluated via area under the ROC curve. RESULTS: The boosted DT classifier yielded the highest cross-validated AUC (= 0.744) for detecting PCa in the discovery cohort. However, in independent validation, the boosted QDA classifier was identified as the most accurate and robust for voxel-wise detection of PCa extent (AUCs of 0.735, 0.683, 0.768 across the 3 sites). The next most accurate and robust classifier was the single QDA classifier, which also enjoyed the advantage of significantly lower computation times compared to any of the other methods. CONCLUSIONS: Our results therefore suggest that simpler classifiers (such as QDA and its ensemble variants) may be more robust, accurate, and efficient for prostate cancer CAD problems, especially in the context of multi-site validation. BioMed Central 2019-02-28 /pmc/articles/PMC6396464/ /pubmed/30819131 http://dx.doi.org/10.1186/s12880-019-0308-6 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Viswanath, Satish E. Chirra, Prathyush V. Yim, Michael C. Rofsky, Neil M. Purysko, Andrei S. Rosen, Mark A. Bloch, B Nicolas Madabhushi, Anant Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title | Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title_full | Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title_fullStr | Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title_full_unstemmed | Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title_short | Comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on T2-weighted MRI: a multi-site study |
title_sort | comparing radiomic classifiers and classifier ensembles for detection of peripheral zone prostate tumors on t2-weighted mri: a multi-site study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6396464/ https://www.ncbi.nlm.nih.gov/pubmed/30819131 http://dx.doi.org/10.1186/s12880-019-0308-6 |
work_keys_str_mv | AT viswanathsatishe comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT chirraprathyushv comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT yimmichaelc comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT rofskyneilm comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT puryskoandreis comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT rosenmarka comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT blochbnicolas comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy AT madabhushianant comparingradiomicclassifiersandclassifierensemblesfordetectionofperipheralzoneprostatetumorsont2weightedmriamultisitestudy |